Exergoeconomic analysis and optimization of a solar driven dual evaporator vapor compression-absorption cascade refrigeration system using water/CuO nanofluid

被引:60
|
作者
Boyaghchi, Fateme Ahmadi [1 ]
Mahmoodnezhad, Motahare [1 ]
Sabeti, Vajiheh [2 ]
机构
[1] Alzahra Univ, Fac Engn & Technol, Dept Mech Engn, Tehran, Iran
[2] Alzahra Univ, Fac Engn & Technol, Dept Comp Engn, Tehran, Iran
关键词
Thermoeconomic; Solar energy; Cascade refrigeration; Nanoparticle; Optimization; NSGA-II; HEAT-TRANSFER PERFORMANCE; METAL-OXIDE NANOFLUIDS; RANKINE-CYCLE ORC; POWER CHP SYSTEM; 2ND LAW ANALYSIS; THERMOECONOMIC OPTIMIZATION; MULTIOBJECTIVE OPTIMIZATION; GENETIC ALGORITHM; LITHIUM BROMIDE; THERMODYNAMIC ANALYSIS;
D O I
10.1016/j.jclepro.2016.08.125
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In this paper, a novel cascade refrigeration system integrated with, flat plate solar collector is modeled and optimized. While LiBr-H2O is applied as fluid pair in cascade absorption section, R134a, R1234ze, R1234yf, R407C and R22 fluids are applied in the vapor compression section and the water/copper oxide (CuO) nanofluid is applied as the heat transfer medium inside the collector subsystem. Nanoparticles volume fraction, mass flow rate of strong solution, low pressure of absorption section, collector tilt angle as well as solar collector area are selected as design parameters while the daily thermal and exergy coefficients of performance and total product cost rate are selected as three objective functions. Non dominated Sort Genetic Algorithm-II (NSGA-II) is individually employed to achieve the final solutions of the system for the best working fluids from the thermodynamic and thermoeconomic viewpoints. The proposed system modeling represents that R134a is the best fluid from the energy and exergy viewpoints with daily energy and exergy coefficients of performance of 9340% and 0.5815%, respectively and R1234ze with the total product cost rate of 7016 $/year is the best working fluid from the exergoeconomic viewpoint. The optimization results indicate that R134a with 2.4% and 2% improvement of the daily energy and exergy coefficients of performance, respectively, relative to the base case needs minimum collector area with amount of 680 m(2) among the other working fluids. In addition, R1234ze with the total product cost rate reduction of 2.4% requires maximum nanoparticles and collector area with values of 0.041 and 702.01 m(2), respectively. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:970 / 985
页数:16
相关论文
共 50 条