A Robust Approach of Single-Phase-to-ground Fault Location for Distribution Grids with Neutrals Non-Effectively Grounded

被引:0
|
作者
Liu, Jian [1 ]
Li, Yunge [1 ]
Zhang, Zhihua [1 ]
Zhang, Xiaoqing [1 ]
Tong, Qianxue [1 ]
机构
[1] Shaanxi Elect Power Res Inst, Xian 710054, Peoples R China
关键词
Bayes theorem; Distribution grid; Distribution Automation System (DAS); Fault location; Master station; Single-phase-to-ground fault;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Locating single-phase-to-ground faults (SGFs) in distribution grids is of great importance to avoid the worsening of the fault and guarantee a continuous and steady power supply. This paper presents an innovative approach of SGF location by using the fault information which is acquired by the fault location devices and sent to the master station of the Distribution Automation System (DAS). The criteria successfully used for locating phase-to-phase faults (PPFs) are modified to locate SGFs. The approaches of making the information binary and differential are described to meet the requirement of the proposed location criteria. Nevertheless, sometimes erroneous information is sent or received. To enhance the robustness of the proposed approach, the Bayes theorem is introduced to take full advantage of the redundancy and correlation of the information from fault location devices with various mechanisms. Two examples are given to prove that a SGF can be located correctly even under the conditions of missing or erroneous information. The proposed approach has been embedded into the Open 5200 Distribution Automation System which is in service in Xi'an. More than ten SGFs have been successfully located.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Non-communication Protection for Single-Phase-to-Ground Fault Feeder in Neutral Non-Effectively Grounded Distribution System
    Jia, Qi
    Dong, Xinzhou
    Shi, Shenxing
    He, Xin
    2018 IEEE POWER & ENERGY SOCIETY GENERAL MEETING (PESGM), 2018,
  • [2] Research on eigenparameters and detection methods for single-phase-to-ground faults in non-effectively grounded distribution systems
    Sheng, Wanxing
    Song, Xiaohui
    IET CYBER-PHYSICAL SYSTEMS: THEORY & APPLICATIONS, 2023, 8 (03) : 205 - 217
  • [3] Segment location for single-phase-to-ground fault in neutral non-effectively grounded system based on distributed electric-field measurement
    Xiao, Dongping
    He, Tao
    Xiao, Ruiyang
    Du, Xuefei
    ELECTRIC POWER SYSTEMS RESEARCH, 2020, 184 (184)
  • [4] Single Line to Ground Fault Detection in a Non-Effectively Grounded Distribution Network
    Wang, Xiaowei
    Gao, Jie
    Wei, Xiangxiang
    Zeng, Zhihui
    Wei, Yanfang
    Kheshti, Mostafa
    IEEE TRANSACTIONS ON POWER DELIVERY, 2018, 33 (06) : 3173 - 3186
  • [5] Phase Current Based Fault Section Location for Single-Phase Grounding Fault in Non-effectively Grounded Distribution Network
    Chang, Zhongxue
    Chang, Nana
    Tan, Weibin
    Zhang, Wei
    Zhang, Zhihua
    Song, Guobing
    2023 IEEE/IAS INDUSTRIAL AND COMMERCIAL POWER SYSTEM ASIA, I&CPS ASIA, 2023, : 219 - 224
  • [6] Location Method Based on Fuzzy Entropy for Single Phase to Ground Faults in Non-effectively Grounded Distribution Network
    Li, Lin
    Gao, Houlei
    Liu, Zhen
    Yuan, Tong
    2023 IEEE BELGRADE POWERTECH, 2023,
  • [7] The Research on multi-criteria fusion strategy of Non-effectively Grounded System Single-phase-to-ground Fault based on the Fuzzy Theory
    Wang, Ruixiao
    Liu, Zhiyu
    Wang, Xinming
    PROGRESS IN MECHATRONICS AND INFORMATION TECHNOLOGY, PTS 1 AND 2, 2014, 462-463 : 209 - 216
  • [8] A ground fault section location method based on active detection approach for non-effectively grounded DC distribution networks*
    Xu, Ruidong
    Song, Guobing
    Chang, Zhongxue
    Zhang, Chenhao
    Yang, Jiayi
    Yang, Xingang
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2023, 152
  • [9] Single phase-to-ground fault line identification and section location method for non-effectively grounded distribution systems based on signal injection
    Pan Z.
    Wang C.
    Cong W.
    Zhang F.
    Transactions of Tianjin University, 2008, 14 (02) : 92 - 96
  • [10] Single Phase-to-Ground Fault Line Identification and Section Location Method for Non-Effectively Grounded Distribution Systems Based on Signal Injection
    潘贞存
    王成山
    丛伟
    张帆
    Transactions of Tianjin University, 2008, (02) : 92 - 96