Comparison of Dynamic and Locking Compression Plates in Humeral Shaft Fractures

被引:0
|
作者
Iqbal, Safdar [1 ]
Malik, Adnan Latif [2 ]
Rehman, Saif Ur [2 ]
Aslam, Farhan [3 ]
Zain-ul-Abidin, Muhammad [3 ]
Abrar-ul-Haq [3 ]
机构
[1] HULS Combined Mil Hosp, Lahore, Pakistan
[2] Sir Ganga Ram Hosp, Orthoped Surg, Lahore, Pakistan
[3] Sir Ganga Ram Hosp, Orthoped Dept, Lahore, Pakistan
来源
关键词
Humeral Shaft Fracture; Locking Compression Plate; Dynamic Compression Plate; Functional Shoulder Outcome;
D O I
10.53350/pjmhs22161306
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives: To compare the functional outcome of shoulder in humeral shaft fractures fixed with dynamic compression plate versus locking compression plate. Design: This was an RCT (randomized controlled trial). Study Settings: It was conducted at the Orthopedic Department of Sir Ganga Ram Hospital Lahore over 1 year from March 2018 to February 2019. Study Procedure: This study involved 62 both male and female patients aged between 18-60 years presenting in orthopedic emergency with humeral shaft fracture. These patients were assigned into two treatment groups randomly. Fracture in Group-A was fixed with dynamic compression plate while locking compression plate was used in Group-B. Outcome variable was functional shoulder outcome which was assessed after 12 weeks of treatment using Modified Constant and Murley Score. An informed written consent was gained from every patient. Results: The mean age of the patients was 42.6 +/- 12.7 years. There were 45 (72.6%) male and 17 (27.4%) female patients in the study group with a male to female ratio of 2.6:1. The mean BMI of these patients was 27.9 +/- 3.4 Kg/m(2) and 17 (27.4%) patients were obese. Left side was more frequently involved (53.2%) as compared to the right side (46.8%). Upon follow-up, the Modified Constant and Murley score was significantly higher in patients treated with DCP as compared to LCP (91.3 +/- 7.4 vs. 85.8 +/- 8.3; p-value=0.008). The frequency of excellent functional shoulder outcome was significantly higher in patients treated with DCP as compared to LCP (87.1% vs. 54.8%; p-value=0.005). When stratified similar difference was observed across various subgroups of patients based on patient's age, gender, side involved, duration since injury and BMI. Conclusion: Dynamic compression plate was associated with significantly better functional shoulder outcome as compared to locking compression plate in patients with humeral shaft fractures regardless of patient's age, gender, duration since injury, side involved and BMI which along with cheaper hardware cost advocates its preferred use in future practice.
引用
收藏
页码:306 / 308
页数:3
相关论文
共 50 条
  • [1] Plate osteosynthesis of fractures of the shaft of the humerus: Comparison of limited contact dynamic compression plates and locking compression plates
    Singh A.K.
    Narsaria N.
    Seth R.R.
    Garg S.
    Journal of Orthopaedics and Traumatology, 2014, 15 (2) : 117 - 122
  • [2] Outcome of locking compression plates in humeral shaft nonunions
    Malhar N. Kumar
    V. Pratap Ravindranath
    M. R. Ravishankar
    Indian Journal of Orthopaedics, 2013, 47 : 150 - 155
  • [3] Outcome of locking compression plates in humeral shaft nonunions
    Biraris, Sandeep R.
    Sonawane, Dhiraj V.
    Patil, Hitendra G.
    Nemade, Pradip S.
    INDIAN JOURNAL OF ORTHOPAEDICS, 2013, 47 (05) : 534 - 534
  • [4] Outcome of locking compression plates in humeral shaft nonunions
    Kumar, Malhar N.
    Ravindranath, V. Pratap
    Ravishankar, M. R.
    INDIAN JOURNAL OF ORTHOPAEDICS, 2013, 47 (02) : 150 - 155
  • [5] Outcome of locking compression plates in humeral shaft nonunions
    Sandeep R. Biraris
    Dhiraj V. Sonawane
    Hitendra G. Patil
    Pradip S. Nemade
    Indian Journal of Orthopaedics, 2013, 47 : 534 - 534
  • [6] Outcome of locking compression plates in humeral shaft nonunions Reply
    Kumar, M. N.
    Ravindranath, V. Pratap
    Ravishankar, M. R.
    INDIAN JOURNAL OF ORTHOPAEDICS, 2013, 47 (05)
  • [7] Humeral shaft fractures treated by dynamic compression plates, Ender nails and interlocking nails
    Ting-Cheng Chao
    Wen-Ying Chou
    Jui-Chang Chung
    Chien-Jen Hsu
    International Orthopaedics, 2005, 29 : 88 - 91
  • [8] Humeral shaft fractures treated by dynamic compression plates, Ender nails and interlocking nails
    Chao, TC
    Chou, WY
    Chung, JC
    Hsu, CJ
    INTERNATIONAL ORTHOPAEDICS, 2005, 29 (02) : 88 - 91
  • [9] Comparison of Locking Compression Plate and Dynamic Compression Plate with Cancellous Bone Graft in Treating Non-Union of Humeral Shaft Fractures
    Khalid, Muhammad Usman
    Saeed, Kazi Muhammad
    Javed, Muhammad Bilal
    Akhtar, Muhammad
    Gillani, Syed Faraz Ul Hassan Shah
    ANNALS OF KING EDWARD MEDICAL UNIVERSITY LAHORE PAKISTAN, 2019, 25 (02):
  • [10] Locking Plates versus Locking Intramedullary Nails Fixation of Proximal Humeral Fractures Involving the Humeral Shaft: A Retrospective Cohort Study
    Song, Hui
    He, Tao
    Guo, Hui-Min Y.
    Li, Zhan-Yu
    Wei, Min
    Zhang, Chao
    Dong, Yu-Qi
    MEDICAL SCIENCE MONITOR, 2020, 26 : e922598