Detection of the Aortic Intimal Tears by using 3D Digital Topology

被引:0
|
作者
Lohou, Christophe [1 ]
Miguel, Bruno [2 ]
机构
[1] Inst Univ Technol Puy En Velay, Dept Informat, 8 Rue Jean Baptiste Fabre,BP 219, F-43006 Le Puy En Velay, France
[2] Clermont Univ, Serv Chirurg Cardio Vasculaire, F-63003 Clermont Ferrand, France
关键词
3D topological analysis; holes closing; aortic intimal tears segmentation; aortic dissection imaging; cardiovascular surgery; interventional techniques; PRESERVATION; SEGMENTATION;
D O I
10.1117/12.877825
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Aortic dissection is a real problem of public health, it is a medical emergency and may quickly lead to death. Aortic dissection is caused by aortal tissue perforation because of blood pressure. It consists of tears (or holes of the intimal tissue) inside lumens. These tears are difficult to detect because they do not correspond to a filled organ to segment; they are usually visually retrieved by radiologists by examining gray level variation on successive image slices, but it remains a very difficult and error-prone task. Our purpose is to detect these intimal tears to help cardiac surgeons in making diagnosis. It would be useful either during a preoperative phase (visualization and location of tears, endoprothesis sizing); or during a peroperative phase (a registration of tears on angiographic images would lead to a more accuracy of surgeon's gestures and thus would enhance care of patient). At this aim, we use Aktouf et al.'s holes filling algorithm proposed in the field of digital topology. This algorithm permits the filling of holes of a 3D binary object by using topological notions - the holes are precisely the intimal tears for our aortic dissection images, after a first preprocessing step. As far as we know, this is the first time that such a proposal is made, even if it is a crucial data for cardiac surgeons. Our study is a preliminary and innovative work; our results are nevertheless considered satisfactory. This approach would also gain to be known to specialists of other diseases.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] Aortic intimal tears: Detection with spiral computed tomography
    Quint, LE
    Platt, JF
    Sonnad, SS
    Deeb, GM
    Williams, DM
    JOURNAL OF ENDOVASCULAR THERAPY, 2003, 10 (03) : 505 - 510
  • [2] TOPOLOGY PRESERVATION IN 3D DIGITAL SPACE
    SAHA, PK
    CHAUDHURI, BB
    CHANDA, B
    MAJUMDER, DD
    PATTERN RECOGNITION, 1994, 27 (02) : 295 - 300
  • [3] 3D digital topology under binary transformation with applications
    Saha, PK
    Chaudhuri, BB
    COMPUTER VISION AND IMAGE UNDERSTANDING, 1996, 63 (03) : 418 - 429
  • [4] Edge Detection in 3D Point Clouds Using Digital Images
    Dolapsaki, Maria Melina
    Georgopoulos, Andreas
    ISPRS INTERNATIONAL JOURNAL OF GEO-INFORMATION, 2021, 10 (04)
  • [5] 3D topology optimization using an immune algorithm
    Campelo, Felipe
    Watanabe, Kota
    Igarashi, Hajime
    COMPEL-THE INTERNATIONAL JOURNAL FOR COMPUTATION AND MATHEMATICS IN ELECTRICAL AND ELECTRONIC ENGINEERING, 2007, 26 (03) : 677 - 688
  • [6] 3D topology optimization using cellular automata
    Kita, E
    Saito, H
    Kobayashi, T
    Xie, YM
    HIGH PERFORMANCE STRUCTURES AND MATERIALS II, 2004, : 473 - 482
  • [7] The detection of circulating tumor DNA using Quantstudio 3D digital PCR
    Greer, Adam H.
    Mills, Glenn
    Yin, Hong
    CANCER RESEARCH, 2015, 75
  • [8] Detection of inhomogeneities in a metal cylinder using ESPI and 3D pulsed digital holography
    Saucedo-Anaya, T
    Santoyo, FM
    Pérez-López, C
    Ibarra, MD
    SIXTH INTERNATIONAL CONFERENCE ON VIBRATION MEASUREMENTS BY LASER TECHNIQUES: ADVANCES AND APPLICATIONS, 2004, 5503 : 398 - 402
  • [9] Motion-based object detection using 3D wave digital filters
    Schauland, Sam
    Velten, Joerg
    Kummert, Anton
    2008 IEEE 8TH INTERNATIONAL CONFERENCE ON COMPUTER AND INFORMATION TECHNOLOGY, VOLS 1 AND 2, 2008, : 857 - 861
  • [10] Using topology derived masks to facilitate 3D design
    Schiek, R
    Schmidt, R
    NSTI NANOTECH 2004, VOL 2, TECHNICAL PROCEEDINGS, 2004, : 291 - 294