Early Prediction of Intensive Care Unit-Acquired Weakness: A Multicenter External Validation Study

被引:15
|
作者
Witteveen, Esther [1 ,2 ,3 ]
Wieske, Luuk [1 ,2 ,3 ]
Sommers, Juultje [4 ]
Spijkstra, Jan-Jaap [5 ]
de Waard, Monique C. [5 ]
Endeman, Henrik [6 ]
Rijkenberg, Saskia [6 ]
de Ruijter, Wouter [7 ]
Sleeswijk, Mengalvio [8 ]
Verhamme, Camiel [2 ]
Schultz, Marcus J. [1 ,3 ]
van Schaik, Ivo N. [2 ]
Horn, Janneke [1 ,3 ]
机构
[1] Acad Med Ctr AMC, Dept Intens Care Med, Amsterdam, Netherlands
[2] Acad Med Ctr AMC, Dept Neurol, Amsterdam, Netherlands
[3] Acad Med Ctr AMC, Lab Expt Intens Care & Anesthesiol LEICA, Amsterdam, Netherlands
[4] Acad Med Ctr AMC, Dept Rehabil, Amsterdam, Netherlands
[5] VU Med Ctr VUmc, Dept Intens Care Med, Amsterdam, Netherlands
[6] OLVG, Dept Intens Care Med, Amsterdam, Netherlands
[7] Noordwest Ziekenhuisgrp, Dept Intens Care Med, Alkmaar, Netherlands
[8] Flevoziekenhuis, Dept Intens Care Med, Almere, Netherlands
关键词
ICU-acquired weakness; prediction; prediction model; predictors; model validation; external validation; CRITICAL ILLNESS; INTEROBSERVER AGREEMENT; INDIVIDUAL PROGNOSIS; DIAGNOSIS TRIPOD; MODEL; STRENGTH; IMPACT;
D O I
10.1177/0885066618771001
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objectives: An early diagnosis of intensive care unit-acquired weakness (ICU-AW) is often not possible due to impaired consciousness. To avoid a diagnostic delay, we previously developed a prediction model, based on single-center data from 212 patients (development cohort), to predict ICU-AW at 2 days after ICU admission. The objective of this study was to investigate the external validity of the original prediction model in a new, multicenter cohort and, if necessary, to update the model. Methods: Newly admitted ICU patients who were mechanically ventilated at 48 hours after ICU admission were included. Predictors were prospectively recorded, and the outcome ICU-AW was defined by an average Medical Research Council score <4. In the validation cohort, consisting of 349 patients, we analyzed performance of the original prediction model by assessment of calibration and discrimination. Additionally, we updated the model in this validation cohort. Finally, we evaluated a new prediction model based on all patients of the development and validation cohort. Results: Of 349 analyzed patients in the validation cohort, 190 (54%) developed ICU-AW. Both model calibration and discrimination of the original model were poor in the validation cohort. The area under the receiver operating characteristics curve (AUC-ROC) was 0.60 (95% confidence interval [CI]: 0.54-0.66). Model updating methods improved calibration but not discrimination. The new prediction model, based on all patients of the development and validation cohort (total of 536 patients) had a fair discrimination, AUC-ROC: 0.70 (95% CI: 0.66-0.75). Conclusions: The previously developed prediction model for ICU-AW showed poor performance in a new independent multicenter validation cohort. Model updating methods improved calibration but not discrimination. The newly derived prediction model showed fair discrimination. This indicates that early prediction of ICU-AW is still challenging and needs further attention.
引用
收藏
页码:595 / 605
页数:11
相关论文
共 50 条
  • [1] Intensive care unit-acquired weakness
    Griffiths, Richard D.
    Hall, Jesse B.
    CRITICAL CARE MEDICINE, 2010, 38 (03) : 779 - 788
  • [2] Intensive Care Unit-Acquired Weakness
    Kramer, Christopher L.
    NEUROLOGIC CLINICS, 2017, 35 (04) : 723 - +
  • [3] Intensive care unit-acquired weakness
    Taylor, Christopher
    ANAESTHESIA AND INTENSIVE CARE MEDICINE, 2024, 25 (01): : 1 - 4
  • [4] Intensive care unit-acquired weakness
    Appleton, Richard
    Kinsella, John
    BJA EDUCATION, 2012, 12 (02) : 62 - 66
  • [5] Intensive care unit-acquired weakness
    Dingezweni, S.
    SOUTHERN AFRICAN JOURNAL OF ANAESTHESIA AND ANALGESIA, 2021, 27 (06) : S141 - S144
  • [6] Intensive care unit-acquired weakness
    van der Jagt, Mathieu
    CRITICAL CARE MEDICINE, 2010, 38 (07) : 1617 - 1619
  • [7] Intensive Care Unit-Acquired Weakness: Neuropathology
    Swash, Michael
    de Carvalho, Mamede
    JOURNAL OF CLINICAL NEUROPHYSIOLOGY, 2020, 37 (03) : 197 - 199
  • [8] Intensive care unit-acquired weakness Reply
    Griffiths, Richard D.
    Hall, Jesse B.
    CRITICAL CARE MEDICINE, 2010, 38 (07) : 1619 - 1619
  • [9] INCREASED EARLY SYSTEMIC INFLAMMATION IN INTENSIVE CARE UNIT-ACQUIRED WEAKNESS
    Witteveen, E.
    Wieske, L.
    van der Poll, T.
    van der Schaaf, M.
    van Schaik, I. N.
    Schultz, M. J.
    Verhamme, C.
    Horn, J.
    JOURNAL OF THE PERIPHERAL NERVOUS SYSTEM, 2015, 20 (02) : 247 - 247
  • [10] Intensive care unit-acquired weakness in the burn population
    Cubitt, Jonathan J.
    Davies, Menna
    Lye, George
    Evans, Janine
    Combellack, Tom
    Dickson, William
    Nguyen, Dai Q.
    JOURNAL OF PLASTIC RECONSTRUCTIVE AND AESTHETIC SURGERY, 2016, 69 (05): : E105 - E109