Fluorescence Spectroscopy as a Tool for Determination of Coumarins by Multivariate Calibration

被引:10
|
作者
Polacek, Roman [1 ]
Majek, Pavel [1 ]
Hrobonova, Katarina [1 ]
Sadecka, Jana [1 ]
机构
[1] Slovak Univ Technol Bratislava, Inst Analyt Chem, Fac Chem & Food Technol, SK-81237 Bratislava, Slovakia
关键词
Synchronous fluorescence spectrometry; Multivariate calibration; Coumarin; 4-hydroxycoumarin; Dicoumarol;
D O I
10.1007/s10895-015-1508-2
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
At present, it is necessary to check the quality of many food products in which the content of coumarins is limited. Since a rapid and simple method for the determination of coumarin (COU), 4-hydroxycoumarin (4HC) and dicoumarol (DC) in tea samples was needed, we developed an alternative option to chromatography, i.e., fluorescence spectroscopy with multivariate calibration. The synchronous fluorescence spectra were recorded at constant wavelength differences 70, 80 and 90 nm from 200 to 400 nm. The different experimental parameters affecting the synchronous fluorescence intensities of the analytes were carefully studied and optimized. Partial least squares (PLS) method and multi linear regression (MLR) were compared on determining the concentrations. The best results were obtained by the PLS method on synchronous fluorescence spectra at Delta lambda = 90 nm. The results from the analysis of herbal tea Melilotus officinalis by synchronous fluorescence spectroscopy with PLS model are equivalent with the results from HPLC. Fisher F- test and Student's t- test confirmed this finding.
引用
收藏
页码:297 / 303
页数:7
相关论文
共 50 条
  • [1] Fluorescence Spectroscopy as a Tool for Determination of Coumarins by Multivariate Calibration
    Roman Poláček
    Pavel Májek
    Katarína Hroboňová
    Jana Sádecká
    Journal of Fluorescence, 2015, 25 : 297 - 303
  • [2] Simultaneous determination of albumin and immunoglobulin G with fluorescence spectroscopy and multivariate calibration
    Wiberg, K
    Sterner-Molin, A
    Jacobsson, SP
    TALANTA, 2004, 62 (03) : 567 - 574
  • [3] Chiral Selector as a Tool for Determination of Enantiomeric Ratio in Mixture by Molecular Spectroscopy with Multivariate Calibration
    Polacek, Roman
    Majek, Pavel
    CHEMICKE LISTY, 2016, 110 (01): : 18 - 25
  • [4] Determination of ochratoxin A in coffee and tea samples by coupling second- order multivariate calibration and fluorescence spectroscopy
    Gonzalez, Albani L.
    Lozano, Valeria A.
    Escandar, Graciela M.
    Bravo, Manuel A.
    TALANTA, 2020, 219
  • [5] Determination of total phenolic content and selected phenolic compounds in sweet wines by fluorescence spectroscopy and multivariate calibration
    Jakubikova, Michaela
    Sadecka, Jana
    Hrobonova, Katarina
    MICROCHEMICAL JOURNAL, 2022, 181
  • [6] A novel application of nylon membranes for tributyltin determination in complex environmental samples by fluorescence spectroscopy and multivariate calibration
    Bravo, Manuel A.
    Escandar, Graciela M.
    Olivieri, Alejandro C.
    Bardin, Emmanuelle
    Aguilar, Luis F.
    Quiroz, Waldo
    CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2015, 148 : 77 - 84
  • [7] Determination of fragrance content in perfume by Raman spectroscopy and multivariate calibration
    Godinho, Robson B.
    Santos, Mauricio C.
    Poppi, Ronei J.
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2016, 157 : 158 - 163
  • [8] The determination of moisture in tobacco by guided microwave spectroscopy and multivariate calibration
    Dane, AD
    Rea, GJ
    Walmsley, AD
    Haswell, SJ
    ANALYTICA CHIMICA ACTA, 2001, 429 (02) : 185 - 194
  • [9] Multivariate calibration for the determination of creatine in urine using UV absorption spectroscopy
    Hill, LM
    Pink, J
    Kaiser, C
    Burke, DG
    Smith-Palmer, T
    CANADIAN JOURNAL OF ANALYTICAL SCIENCES AND SPECTROSCOPY, 2003, 48 (05): : 308 - 313
  • [10] Determination of motor gasoline adulteration using FTIR spectroscopy and multivariate calibration
    Al-Ghouti, Mohammad A.
    Al-Degs, Yahya S.
    Amer, Mohammad
    TALANTA, 2008, 76 (05) : 1105 - 1112