Compact movable microwire array for long-term chronic unit recording in cerebral cortex of primates

被引:126
|
作者
Jackson, Andrew
Fetz, Eberhard E.
机构
[1] Univ Washington, Dept Physiol & Biophys, Newcastle Upon Tyne, Tyne & Wear, England
[2] Univ Washington, Washington Natl Primate Res Ctr, Newcastle Upon Tyne, Tyne & Wear, England
关键词
D O I
10.1152/jn.00569.2007
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
We describe a small, chronically implantable microwire array for obtaining long-term unit recordings from the cortex of unrestrained nonhuman primates. After implantation, the depth of microwires can be individually adjusted to maintain large-amplitude action potential recordings from single neurons over many months. We present data recorded from the primary motor cortex of two monkeys by autonomous on-board electronic circuitry. Waveforms of individual neurons remained stable for recording periods of several weeks during unrestrained behavior. Signal-to-noise ratios, waveform stability, and rates of cell loss indicate that this method may be particularly suited to experiments investigating the neural correlates of processes extending over multiple days, such as learning and plasticity.
引用
收藏
页码:3109 / 3118
页数:10
相关论文
共 50 条
  • [1] A bundled microwire array for long-term chronic single-unit recording in deep brain regions of behaving rats
    Tseng, Wan-Ting
    Yen, Chen-Tung
    Tsai, Meng-Li
    JOURNAL OF NEUROSCIENCE METHODS, 2011, 201 (02) : 368 - 376
  • [2] Long-term neural recording characteristics of wire microelectrode arrays implanted in cerebral cortex
    Williams, JC
    Rennaker, RL
    Kipke, DR
    BRAIN RESEARCH PROTOCOLS, 1999, 4 (03): : 303 - 313
  • [3] A Laser Doppler System for Long-Term Recording of Cerebral Microcirculation in the Neurointensive Care Unit
    Mauritzon, Stina
    Ginstman, Fredrik
    Wardell, Karin
    TRANSLATIONAL BIOPHOTONICS: DIAGNOSTICS AND THERAPEUTICS, 2021, 11919
  • [4] MICROWIRE TECHNIQUE FOR LONG-TERM RECORDING OF SINGLE UNITS IN BRAINS OF UNRESTRAINED ANIMALS
    PALMER, C
    JOURNAL OF PHYSIOLOGY-LONDON, 1976, 263 (01): : P99 - P101
  • [5] A MULTIPLE FLOATING MICROELECTRODE FOR CHRONIC IMPLANTATION AND LONG-TERM SINGLE UNIT RECORDING IN THE CAT
    LEGENDY, CR
    SALCMAN, M
    BRENNAN, N
    ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1984, 58 (03): : 285 - 288
  • [6] Consolidation of visual associative long-term memory in the temporal cortex of primates
    Miyashita, Y
    Kameyama, M
    Hasegawa, I
    Fukushima, L
    NEUROBIOLOGY OF LEARNING AND MEMORY, 1998, 70 (1-2) : 197 - 211
  • [7] LONG-TERM PREOPTIC UNIT RECORDING IN FREELY MOVING RATS
    KIYOHARA, T
    HORI, T
    SHIBATA, M
    NAKASHIMA, T
    YAMASAKI, M
    INTERNATIONAL JOURNAL OF BIOMETEOROLOGY, 1986, 30 (04) : 379 - 380
  • [8] Silicon-substrate intracortical microelectrode arrays for long-term recording of neuronal spike activity in cerebral cortex
    Kipke, DR
    Vetter, RJ
    Williams, JC
    Hetke, JF
    IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2003, 11 (02) : 151 - 155
  • [9] Long-Term Plasticity of Glutamatergic Synaptic Transmission in the Cerebral Cortex
    Crozier, Robert A.
    Philpot, Benjamin D.
    Sawtell, Nathaniel B.
    Bear, Mark F.
    COGNITIVE NEUROSCIENCES III, THIRD EDITION, 2004, : 109 - 126
  • [10] A carbon-fiber electrode array for long-term neural recording
    Guitchounts, Grigori
    Markowitz, Jeffrey E.
    Liberti, William A.
    Gardner, Timothy J.
    JOURNAL OF NEURAL ENGINEERING, 2013, 10 (04)