Neutron-induced background in charge-coupled device detectors

被引:14
|
作者
Jaanimagi, PA [1 ]
Boni, R [1 ]
Keck, RL [1 ]
机构
[1] Univ Rochester, Laser Energet Lab, Rochester, NY 14623 USA
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2001年 / 72卷 / 01期
关键词
D O I
10.1063/1.1319871
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The inertial confinement fusion (ICF) community must become more cognizant of the neutron-induced background levels in charge-coupled device (CCD) detectors that are replacing film as the recording medium in many ICF diagnostics. This background degrades the signal-to-noise ratio (SNR) of the recorded signals and for the highest-yield shots comprises a substantial fraction of the pixel's full well capacity. CCD detectors located anywhere in the OMEGA Target Bay are precluded from recording high precision signals (SNR > 30) for deuterium-tritium neutron yields greater than 10(13). CCDs make excellent calibrated neutron detectors. The average CCD background level is proportional to the neutron yield, and we have measured a linear response over four decades. The spectrum of deposited energy per pixel is heavily weighted to low energies, < 50 keV, with a few isolated saturated pixels. Most of the background recorded by the CCDs is due to secondary radiation produced by interactions of the primary neutrons with all the materials in the Target Bay as well as the shield walls and the floor. Since the noise source comes from all directions it is very difficult to shield. The fallback position of using film instead of CCD cameras for high-neutron-yield target shots is flawed, as we have observed substantially increased fog levels on our x-ray recording film as a function of the neutron yield. (C) 2001 American Institute of Physics.
引用
收藏
页码:801 / 804
页数:4
相关论文
共 50 条
  • [1] THE CAPABILITIES OF CHARGE-COUPLED DEVICE (CCD) DETECTORS
    PURLL, DJ
    OBSERVATORY, 1981, 101 (1044): : 138 - 138
  • [2] Charge-coupled device-based area detectors
    Westbrook, EM
    Naday, I
    MACROMOLECULAR CRYSTALLOGRAPHY, PT A, 1997, 276 : 244 - 268
  • [3] Experimental study on neutron-induced charge transfer degradation of linear charge coupled device
    Xiao, Zhi-Gang
    Tang, Ben-Qi
    Li, Jun-Li
    Zhang, Yong
    Liu, Min-Bo
    Wang, Zu-Jun
    Huang, Shao-Yan
    Yuanzineng Kexue Jishu/Atomic Energy Science and Technology, 2007, 41 (01): : 117 - 120
  • [4] Charge-coupled device area x-ray detectors
    Gruner, SM
    Tate, MW
    Eikenberry, EF
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2002, 73 (08): : 2815 - 2842
  • [5] ELECTRON BOMBARDED CHARGE-COUPLED DEVICE (CCD) DETECTORS FOR THE VACUUM ULTRAVIOLET
    LOWRANCE, JL
    CARRUTHERS, GR
    PROCEEDINGS OF THE SOCIETY OF PHOTO-OPTICAL INSTRUMENTATION ENGINEERS, 1981, 279 : 123 - 128
  • [6] Calibration procedures for charge-coupled device x-ray detectors
    Barna, S.L.
    Tate, M.W.
    Gruner, S.M.
    Eikenberry, E.F.
    Review of Scientific Instruments, 70 (07):
  • [7] Calibration procedures for charge-coupled device x-ray detectors
    Barna, SL
    Tate, MW
    Gruner, SM
    Eikenberry, EF
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1999, 70 (07): : 2927 - 2934
  • [8] USE OF CHARGE-COUPLED DEVICE (CCD) DETECTORS FOR IMAGING IN THE VACUUM ULTRAVIOLET
    MICHELS, D
    BURSTEIN, P
    PROCEEDINGS OF THE SOCIETY OF PHOTO-OPTICAL INSTRUMENTATION ENGINEERS, 1981, 279 : 140 - 145
  • [9] A CHARGE-COUPLED DEVICE FOR AMATEURS
    BUIL, C
    SKY AND TELESCOPE, 1985, 69 (01): : 71 - 73
  • [10] UNIPHASE CHARGE-COUPLED DEVICE
    GELBERGER, PP
    SALAMA, CAT
    PROCEEDINGS OF THE INSTITUTE OF ELECTRICAL AND ELECTRONICS ENGINEERS, 1972, 60 (06): : 721 - +