摘要
Wireless measurement of ionizing radiation in close proximity or/and within an irradiated solid tumor is extremely valuable for dose verification and quality control in radiation oncology. For such applications, it is preferable to manufacture such sensors using passive components since high levels of ionizing radiation can damage active electronics. In addition, passive implementation can reduce the cost associated with fabrication and assembly. This paper reports on the development of an implantable micromachined passive LC transponder for in situ radiation measurement. Dose measurement is performed by monitoring the resonance frequency change associated with the decay of surface change of an electret upon exposure to radiation. This is achieved through a micromachned capacitor with a movable plate that is partially filled with a Teflon electret and connected in parallel with an inductor, thus forming a passive LC tank circuit. For an implantable prototype encapsulated in a glass capsule (2.5 mm in diameter, 2.8 cm in length), test results show that a dose of 30 Gy (from a Co-60 source) can produce 1.46 MHz frequency shift resulting in a sensitivity of 49 kHz/Gy.
引用
收藏
页码:1772 / 1775
页数:4
相关论文
共 50 条
  • [1] An implantable wireless microdosimeter for radiation oncology
    Son, C.
    Ziaie, B.
    MEMS 2008: 21ST IEEE INTERNATIONAL CONFERENCE ON MICRO ELECTRO MECHANICAL SYSTEMS, TECHNICAL DIGEST, 2008, : 256 - 259
  • [2] Implantable Wireless Dosimeters for Radiation Oncology
    Maleki, T.
    Son, C.
    Ziaie, B.
    2009 IEEE INTERNATIONAL ELECTRON DEVICES MEETING, 2009, : 547 - +
  • [3] A Wireless and Passive Implantable Pressure Sensor
    Tan, Ee Lim
    Pereles, Brandon D.
    Ong, Keat Ghee
    SENSOR LETTERS, 2009, 7 (01) : 57 - 63
  • [4] Wireless implantable passive strain sensor
    Gattiker, Felix
    Neuenschwander, Juerg
    Sennhauser, Urs
    Umbrecht, Florian
    Hierold, Christopher
    TM-TECHNISCHES MESSEN, 2008, 75 (02) : 110 - 119
  • [5] A wireless Implantable passive strain sensor system
    Umbrecht, F
    Wendlandt, M
    Juncker, D
    Hierold, C
    2005 IEEE SENSORS, VOLS 1 AND 2, 2005, : 20 - 23
  • [6] Wireless and Passive Nuclear Radiation Sensors
    Arenas, C.
    Philippe, J.
    Henry, D.
    Rumeau, A.
    Coustou, A.
    Aubert, H.
    Pons, P.
    2017 47TH EUROPEAN MICROWAVE CONFERENCE (EUMC), 2017, : 113 - 116
  • [7] Evaluation of an Implantable Passive Sensor for Wireless Intracranial Pressure Monitoring
    Behfar, Mohammad
    Moradi, Elham
    Bjorninen, Toni
    Sydanheimo, Lauri
    Ukkonen, Leena
    2015 IEEE INTERNATIONAL SYMPOSIUM ON ANTENNAS AND PROPAGATION & USNC/URSI NATIONAL RADIO SCIENCE MEETING, 2015, : 1201 - 1202
  • [8] Wireless implantable passive strain sensor: design, fabrication and characterization
    Umbrecht, F.
    Waegli, P.
    Dechand, S.
    Gattiker, F.
    Neuenschwander, J.
    Sennhauser, U.
    Hierold, Ch
    JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2010, 20 (08)
  • [9] Implantable real time microdosimeter system: Experimental methods and results
    Nakata, Eiko
    Yamada, Shogo
    Momose, Genki
    Kikuchi, Youhei
    Ogawa, Yoshihiro
    Mori, Issei
    Oishi, Mikio
    Ishii, Keizo
    FUTURE MEDICAL ENGINEERING BASED ON BIONANOTECHNOLOGY, PROCEEDINGS, 2006, : 473 - +
  • [10] Wireless switch for implantable medical devices based on passive RF receiver
    Jiang, H.
    Zhang, L.
    Zhang, C.
    Wang, Z.
    ELECTRONICS LETTERS, 2008, 44 (17) : 1006 - 1007