Electrochemical Immunoassay with Dual-Signal Amplification for Redox Cycling within a Nanoscale Gap

被引:5
|
作者
Ito, Kentaro [1 ]
Inoue, Kumi Y. [1 ,3 ]
Ito-Sasaki, Takahiro [1 ]
Ino, Kosuke [2 ]
Shiku, Hitoshi [2 ]
机构
[1] Tohoku Univ, Grad Sch Environm Studies, Sendai, Miyagi 9808579, Japan
[2] Tohoku Univ, Dept Biomol Engn, Grad Sch Engn, Sendai, Miyagi 9808579, Japan
[3] Univ Yamanashi, Fac Engn Grad Fac Interdisciplinary Res, Ctr Basic Educ, Kofu, Yamanashi 4008511, Japan
基金
日本学术振兴会; 日本科学技术振兴机构;
关键词
electrochemical immunosensor; redox cycling; Limulus amebocyte lysate reaction; endotoxin; ENDOTOXIN; SENSITIVITY; SENSOR; FLUCTUATIONS; MOLECULES; STRATEGY; SYSTEM; ARRAYS;
D O I
10.1021/acsanm.1c02837
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Here, we report a highly sensitive and easy-to-use electrochemical immunoassay using a dual-signal amplification strategy of redox cycling within a nanoscale gap and the Limulus amebocyte lysate (LAL) cascade reaction. After the antigen-antibody reaction using an endotoxin-labeled antibody, the LAL reaction was induced by endotoxin as the first signal amplification. Subsequently, p-aminophenol (pAP) liberated from peptideconjugated pAP (Boc-Leu-Gly-Arg-pAP; LGR-pAP), at the last step of the LAL reaction, was detected with redox cycling within a nanoscale gap using a fabricated device as the second signal amplification. First, an electrochemical immunoassay for goat immunoglobulin G (IgG), used as a model analyte, was performed with an endotoxin-labeled antibody using a 96-well plate. The results indicated that the endotoxin-labeled antibody was usable for immunoassays. However, a high background was observed. To decrease the background and increase the efficiency of the reactions, magnetic beads in an endotoxin-free test tube were used for the immunosorbent assay. After optimization of the condition, goat IgG was successfully detected with single-signal amplification of the cascade reaction at concentrations as low as 10 pg/mL (67 fM) using a Au disc electrode. Finally, an immunoassay for goat IgG on magnetic beads using a redox cycling-inducing device was performed. With the dual-signal amplification strategies of redox cycling within a nanoscale gap and LAL reactions, the detection limit was 70 fg/mL (470 aM). Our highly sensitive and easy-to-use immunoassay strategy provides a platform for clinical diagnosis to detect early-stage infections.
引用
收藏
页码:12393 / 12400
页数:8
相关论文
共 50 条
  • [1] High-Sensitivity Amperometric Dual Immunoassay Using Two Cascade Reactions with Signal Amplification of Redox Cycling in Nanoscale Gap
    Ito, Kentaro
    Inoue, Kumi Y.
    Ino, Kosuke
    Shiku, Hitoshi
    ANALYTICAL CHEMISTRY, 2022, 94 (47) : 16451 - 16460
  • [2] Nanoscale Electrochemical Sensor Arrays: Redox Cycling Amplification in Dual-Electrode Systems
    Wolfrum, Bernhard
    Kaetelhoen, Enno
    Yakushenko, Alexey
    Krause, Kay J.
    Adly, Nouran
    Hueske, Martin
    Rinklin, Philipp
    ACCOUNTS OF CHEMICAL RESEARCH, 2016, 49 (09) : 2031 - 2040
  • [3] SWCNTs@GQDs composites as nanocarriers for enzyme-free dual-signal amplification electrochemical immunoassay of cancer biomarker
    Luo, Yanan
    Wang, Yuxin
    Yan, Hongye
    Wu, Yu
    Zhu, Chengzhou
    Du, Dan
    Lin, Yuehe
    ANALYTICA CHIMICA ACTA, 2018, 1042 : 44 - 51
  • [4] Electrochemical immunosensors based on the solubility difference of electroactive probe and the dual signal amplification of nanocarrier plus redox cycling
    Chang, Yong
    Wang, Yajun
    Fan, Xueqian
    Zhou, Jia
    Lv, Yunhe
    Xia, Ning
    BIOELECTROCHEMISTRY, 2025, 162
  • [5] Imaging sensor array coupled with dual-signal amplification strategy for ultrasensitive chemiluminescence immunoassay of multiple mycotoxins
    Zong, Chen
    Jiang, Fan
    Wang, Xiaoyu
    Li, Ping
    Xu, Linru
    Yang, Hua
    BIOSENSORS & BIOELECTRONICS, 2021, 177
  • [6] Alkaline phosphatase-triggered dual-signal immunoassay for colorimetric and electrochemical detection of zearalenone in cornmeal
    Shang, Cuiling
    Li, Yansong
    Zhang, Qi
    Tang, Song
    Tang, Xiaoqian
    Ren, Honglin
    Hu, Pan
    Lu, Shiying
    Li, Peiwu
    Zhou, Yu
    SENSORS AND ACTUATORS B-CHEMICAL, 2022, 358
  • [7] Alkaline phosphatase-triggered dual-signal immunoassay for colorimetric and electrochemical detection of zearalenone in cornmeal
    Shang, Cuiling
    Li, Yansong
    Zhang, Qi
    Tang, Song
    Tang, Xiaoqian
    Ren, Honglin
    Hu, Pan
    Lu, Shiying
    Li, Peiwu
    Zhou, Yu
    Sensors and Actuators B: Chemical, 2022, 358
  • [8] Dual-signal heterodyne lock-in amplification with lasers
    Witteman, W. J.
    LASER PHYSICS, 2006, 16 (01) : 202 - 210
  • [9] Rapid quantitative detection of capsaicinoids in serum based on an electrochemical immunosensor with a dual-signal amplification strategy
    Qingxue Zhao
    Yuxiang Wu
    Xiaojie Shi
    Haowei Dong
    Huimin Liu
    Yan Zheng
    Qingqing Yang
    Xia Sun
    Yemin Guo
    Shancang Zhao
    Journal of Solid State Electrochemistry, 2021, 25 : 671 - 681
  • [10] Dual-signal based immunoassay for colorimetric and photothermal detection of furazolidone
    Su, Lihong
    Chen, Yaqian
    Wang, Lulu
    Zhang, Han
    Sun, Jing
    Wang, Jianlong
    Zhang, Daohong
    SENSORS AND ACTUATORS B-CHEMICAL, 2021, 331