Simultaneous voltammetric detection of ascorbic acid, dopamine and uric acid using a pyrolytic graphite electrode modified into dopamine solution

被引:156
|
作者
da Silva, Robson P. [1 ]
Lima, Antonio William O. [1 ]
Serrano, Silvia H. P. [1 ]
机构
[1] Univ Sao Paulo, Inst Chem, BR-05513970 Sao Paulo, Brazil
基金
巴西圣保罗研究基金会;
关键词
pyrolytic graphite modified; electrode; uric and ascorbic acids; dopamine; biological fluids; differential pulse voltammetry;
D O I
10.1016/j.aca.2008.02.017
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Pyrolytic graphite electrodes (PGE) were modified into dopamine solutions using phosphate buffer solutions, pH 10 and 6.5, as supporting electrolyte. The modification process involved a previous anodization of the working electrode at +1. 5 V into 0. 1 mol-L-1 NaOH followed by other anodization step, in the same experimental conditions, into dopamine (DA) solutions. pH of the supporting electrolyte performed an important role in the production of a superficial melanin polymeric film, which permitted the simultaneous detection of ascorbic acid (AA), (DA) and uric acid (UA), Delta EAA-DA = 222 mV-, Delta EAA-UA = 360 mV and Delta EDA-UA=138mV, avoiding the superficial poisoning effects. The calculated detection limits were: 1.4 x 10(-6) mol L-1 for uric acid, 1.3x10-(5) molL(-1) for ascorbic acid and 1.1 X 10(-7) mol L-1 for dopamine, with sensitivities of (7.7 +/- 0.5), (0.061 +/- 0.001) and (9.5 +/- 0.05)A mol(-1) cm(-2), respectively, with no mutual interference. Uric acid was determined in urine, blood and serum human samples after dilution in phosphate buffer and no additional sample pre-treatment was necessary. The concentration of uric acid in urine was higher than the values found in blood and serum and the recovery tests (92-102%) indicated that no matrix effects were observed. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:89 / 98
页数:10
相关论文
共 50 条
  • [1] A mesoporous carbon nanofiber-modified pyrolytic graphite electrode used for the simultaneous determination of dopamine, uric acid, and ascorbic acid
    Yue, Ying
    Hu, Guangzhi
    Zheng, Mingbo
    Guo, Yong
    Cao, Jieming
    Shao, Shijun
    CARBON, 2012, 50 (01) : 107 - 114
  • [2] Detection of Uric Acid in the Presence of Dopamine and High Concentration of Ascorbic Acid Using PDDA Modified Graphite Electrode
    Manjunatha, Hanumanthrayappa
    Nagaraju, Doddahalli Hanumantharayudu
    Suresh, Gurukar Shivappa
    Venkatesha, Thimmappa Venkatarangaiah
    ELECTROANALYSIS, 2009, 21 (20) : 2198 - 2206
  • [3] Simultaneous voltammetric detection of dopamine, ascorbic acid and uric acid using a poly(2-(Nmorpholine) ethane sulfonic acid)/RGO modified electrode
    Zhang, Keying
    Zhang, Na
    Zhang, Li
    Wang, Hongyan
    Shi, Hongwei
    Liu, Qiao
    RSC ADVANCES, 2018, 8 (10): : 5280 - 5285
  • [4] Simultaneous detection of dopamine, tyrosine and ascorbic acid using NiO/graphene modified graphite electrode
    Swamy, Budde Kumar
    Shiprath, Kudekallu
    Rakesh, Gunnam
    Ratnam, K. Venkata
    Manjunatha, H.
    Janardan, S.
    Naidu, K. Chandra Babu
    Ramesh, S.
    Suresh, Kothanlasu
    Ratnamala, A.
    BIOINTERFACE RESEARCH IN APPLIED CHEMISTRY, 2020, 10 (03): : 5599 - 5609
  • [5] Simultaneous determination of dopamine and ascorbic acid at glutamic acid modified graphite electrode
    Lin, XQ
    Zhang, L
    ANALYTICAL LETTERS, 2001, 34 (10) : 1585 - 1601
  • [6] Poly(thionine)-modified GC Electrode for Simultaneous Detection of Dopamine and Uric Acid in the Presence of Ascorbic Acid
    Yuan, Yong
    Ahammad, A. J. Saleh
    Xu, Guang-Ri
    Kim, Sunghyun
    Lee, Jae-Joon
    BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2008, 29 (10) : 1883 - 1884
  • [7] Solar graphene modified glassy carbon electrode for the voltammetric resolution and detection of dopamine, ascorbic acid and uric acid
    Nancy, T. E. Mary
    Anithakumary, V.
    Swamy, B. E. Kumara
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2014, 720 : 107 - 114
  • [8] Poly(thionine)-modified GC electrode for simultaneous detection of dopamine and uric acid in the presence of ascorbic acid
    Yuan, Yong
    Ahammad, A. J. Saleh
    Xu, Guang-Ri
    Kim, Sunghyun
    Lee, Jae-Joon
    1883, Korean Chemical Society, Seoul, 135-703, South Korea (29)
  • [9] Simultaneous Detection of Ascorbic Acid, Dopamine, Uric Acid and Tryptophan on the PEI-graphene Modified Electrode
    Li Chong
    Jia Liping
    Ma Rongna
    Jia Wenli
    Wang Huaisheng
    Yang Haitao
    Guo Aixiang
    CHEMICAL JOURNAL OF CHINESE UNIVERSITIES-CHINESE, 2015, 36 (07): : 1282 - 1290
  • [10] Simultaneous determination of dopamine, ascorbic acid, and uric acid using helical carbon nanotubes modified electrode
    Cui, Rongjing
    Wang, Xueying
    Zhang, Genhua
    Wang, Chen
    SENSORS AND ACTUATORS B-CHEMICAL, 2012, 161 (01): : 1139 - 1143