Bolted Connection of an End-Plate Cantilever Beam: The Distribution of Operating Force

被引:9
|
作者
Oman, Simon [1 ]
Nagode, Marko [1 ]
机构
[1] Univ Ljubljana, Fac Mech Engn, Askerceva 6, SI-1000 Ljubljana, Slovenia
关键词
bolted connection; endplate connection; operating force; bolt pretension; structural steel; finite element method; COLUMN CONNECTIONS; BEHAVIOR; JOINTS; SIMULATION;
D O I
10.5545/sv-jme.2017.4638
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
This paper presents an alternative method for calculating the operating forces on bolts in the bolted connections of the end-plate cantilever beams. Since operating force reduces pressure between the joined surfaces the influence of the operating force needs to be considered when determining the clamping force. Therefore, correctly defined operational force on each bolt is a base for all further calculations. To evaluate proposed method, results of four existing analytical methods for calculating the operating forces in the bolted connections of the end-plate cantilever beams are compared with the results of the alternative method and the results gained by finite element analyses. Because finite element analysis take into account all influential parameters it is expected that the results obtained by finite element analyses are a good approximation to reality and can serve as a reference when comparing different analytical methods. It turns out that the results of the proposed method coincide with the results of finite element analyses the most. Only the proposed method correctly determines which bolts in the connection are subjected to the highest additional loads.
引用
收藏
页码:617 / 627
页数:11
相关论文
共 50 条
  • [1] On the assessment of a new steel bolted flush end-plate beam splice connection
    Keikha, H.
    Mofid, M.
    SCIENTIA IRANICA, 2017, 24 (04) : 1735 - 1750
  • [2] COMPUTER MODELING OF AN EXTENDED END-PLATE BOLTED CONNECTION
    BAHAARI, MR
    SHERBOURNE, AN
    COMPUTERS & STRUCTURES, 1994, 52 (05) : 879 - 893
  • [3] Application of superelasticity of SMAs in bolted end-plate connection
    Ma, Hongwei
    Cho, Chongdu
    PROGRESSES IN FRACTURE AND STRENGTH OF MATERIALS AND STRUCTURES, 1-4, 2007, 353-358 : 3039 - +
  • [4] Modeling of end-plate bolted composite connection in fire considering axial force effects
    Li, Guo-Qiang
    Chen, Ling-Zhu
    Li, Jiao-Ting
    Lou, Guo-Biao
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2012, 76 : 133 - 143
  • [5] Post-earthquake fire resistance of bolted end-plate connection joint with end-plate and web stiffeners
    Xu, Jixiang
    Wang, Jianjun
    Mohamed, Hazem Samih
    Han, Jianping
    Han, Zhaolong
    Tu, Jiahuang
    Li, Zhanjie
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2021, 185
  • [6] Nonlinear analysis of force distribution in bolted flush end plate moment connection
    Dept. of Structural Engineering, Faculty of Engineering, Cairo University, Giza, Egypt
    J. Eng. Appl. Sci., 4 (399-422):
  • [7] Experimental study on a new type of assembly bolted end-plate connection
    Li, Shufeng
    Li, Qingning
    Jiang, Haotian
    Zhang, Hao
    Yan, Lei
    Jiang, Weishan
    STEEL AND COMPOSITE STRUCTURES, 2018, 26 (04): : 463 - 471
  • [8] Experimental investigation on flush end-plate bolted composite connection in fire
    Li, Jiao-Ting
    Li, Guo-Qiang
    Lou, Guo-Biao
    Chen, Ling-zhu
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2012, 76 : 121 - 132
  • [9] Seismic performance of bolted connection of H-beam to HSS-column with web end-plate
    Liu, Xue Chun
    Cui, Fu Yuan
    Zhan, Xin Xin
    Yu, Cheng
    Jiang, Zi Qin
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2019, 156 : 167 - 181
  • [10] Parametric study of Stub-Beam Bolted Extended End-Plate connection to box-columns
    Behrooz, Sasan Mahjoob
    Erfani, Saeed
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2020, 171 (171)