Pulmonary effects of methylprednisolone in patients undergoing coronary artery bypass grafting and early tracheal extubation

被引:98
|
作者
Chaney, MA
Nikolov, MP
机构
[1] Loyola Univ, Med Ctr, Foster G McGaw Hosp, Dept Anesthesiol, Maywood, IL 60153 USA
[2] Loyola Univ, Med Ctr, Foster G McGaw Hosp, Dept Thorac & Cardiovasc Surg, Maywood, IL 60153 USA
来源
ANESTHESIA AND ANALGESIA | 1998年 / 87卷 / 01期
关键词
D O I
10.1097/00000539-199807000-00007
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Numerous clinical studies suggest that methylprednisolone may facilitate early tracheal extubation after cardiac surgery, yet no investigation has rigorously examined the use of the drug in this setting. In this prospective, randomized, double-blind, placebo-controlled study, we examined the pulmonary effects of methylprednisolone in patients undergoing coronary artery bypass grafting (CABG) and early tracheal extubation. Sixty patients undergoing elective CABG and early tracheal extubation were randomized into two groups. Group MP patients received TV methylprednisolone (30 mg/kg during sternotomy and 30 mg/kg during initiation of cardiopulmonary bypass) and Group NS patients received IV placebo at the same two times. Perioperative management was standardized. Alveolar-arterial (A-a) oxygen gradient, lung compliance, shunt, and dead space were determined four times perioperatively. Postoperative tracheal extubation was accomplished at the earliest appropriate time. Both groups exhibited significant postoperative increases in A-a oxygen gradient and shunt (P < 0.000001 for each group) and significant postoperative decreases in dynamic lung compliance (P < 0.000001 for each group). Patients in Group MP exhibited significantly larger increases in postoperative A-a oxygen gradient (P = 0.001) and shunt (P = 0.001) compared with patients in Group NS. Postoperative alterations in dynamic lung compliance, static lung compliance, and dead space were not statistically significant between the groups. The time to postoperative tracheal extubation was prolonged in Group MP patients compared with Group NS patients (769 +/- 294 vs 604 +/- 315 min, respectively; P = 0.05). Methylprednisolone was associated with larger increases in postoperative A-a oxygen gradient and shunt, was unable to prevent postoperative decreases in lung compliance, and prolonged extubation time, which indicate that use of the drug may hinder early tracheal extubation in patients after cardiac surgery. Implications: Traditionally, methylprednisolone has been administered to patients undergoing cardiac surgery to decrease postoperative pulmonary dysfunction. This study revealed that the drug is associated with larger increases in postoperative alveolar-arterial oxygen gradient and shunt and prolonged tracheal extubation time in patients undergoing coronary artery bypass grafting, which indicate that use of the drug may hinder early tracheal extubation.
引用
收藏
页码:27 / 33
页数:7
相关论文
共 50 条
  • [1] Methylprednisolone does not benefit patients undergoing coronary artery bypass grafting and early tracheal extubation
    Chaney, MA
    Durazo-Arvizu, RA
    Nikolov, MP
    Blakeman, BP
    Bakhos, M
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2001, 121 (03): : 561 - 569
  • [2] Methylprednisolone for coronary artery bypass grafting and early extubation
    Chaney, MA
    Nikolov, MP
    Slogoff, S
    ANESTHESIA AND ANALGESIA, 1998, 86 (2S):
  • [3] Early tracheal extubation after coronary artery bypass grafting
    Juca, R
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1997, 114 (04): : 687 - 687
  • [4] Early Tracheal Extubation after On-Pump Coronary Artery Bypass Grafting
    Sato, Manabu
    Suenaga, Etsuro
    Koga, Shugo
    Matsuyama, Shigefumi
    Kawasaki, Hiromitsu
    Maki, Fumie
    ANNALS OF THORACIC AND CARDIOVASCULAR SURGERY, 2009, 15 (04) : 239 - 242
  • [5] Predictive risk factors for delayed extubation in patients undergoing coronary artery bypass grafting
    Y. Suematsu
    Hajime Sato
    Toshiya Ohtsuka
    Yutaka Kotsuka
    Shunichi Araki
    Shinichi Takamoto
    Heart and Vessels, 2000, 15 : 214 - 220
  • [6] Predictive risk factors for delayed extubation in patients undergoing coronary artery bypass grafting
    Suematsu, Y
    Sato, H
    Ohtsuka, T
    Kotsuka, Y
    Araki, S
    Takamoto, S
    HEART AND VESSELS, 2000, 15 (05) : 214 - 220
  • [7] Postoperative pulmonary function in coronary artery bypass graft surgery patients undergoing early tracheal extubation: A comparison between short-term mechanical ventilation and early extubation
    Nicholson, DJ
    Kowalski, SE
    Hamilton, GA
    Meyers, MP
    Serrette, C
    Duke, PC
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2002, 16 (01) : 27 - 31
  • [8] Intrathecal morphine for coronary artery bypass grafting and early extubation
    Chaney, MA
    Furry, PA
    Fluder, EM
    Slogoff, S
    ANESTHESIA AND ANALGESIA, 1997, 84 (02): : 241 - 248
  • [9] Hemodynamic effects of cisatracurium in patients undergoing coronary artery bypass grafting
    Carroll, MT
    O'Hare, R
    Elliott, P
    Gibson, FM
    Mirakhur, RK
    ANESTHESIOLOGY, 1998, 89 (3A) : U850 - U850
  • [10] The effects of pulmonary hypertension on early outcomes in patients undergoing coronary artery bypass surgery
    Akca, Baris
    Donmez, Koksal
    Disli, Olcay Murat
    Akgul Erdil, Feray
    Colak, Mehmet Cengiz
    Aydemir, Ilhan Koray
    Battaloglu, Bektas
    Erdil, Nevzat
    TURKISH JOURNAL OF MEDICAL SCIENCES, 2016, 46 (04) : 1162 - 1167