Iprodione Removal by UV-Light-, Zero-Valent Iron- and Zero-Valent Aluminium-Activated Persulfate Oxidation Processes in Pure Water and Simulated Tertiary Treated Urban Wastewater

被引:3
|
作者
Montazeri, Bahareh [1 ]
Koba-Ucun, Olga [1 ]
Arslan-Alaton, Idil [1 ]
Olmez-Hanci, Tugba [1 ]
机构
[1] Istanbul Tech Univ, Sch Civil Engn, Dept Environm Engn, Ayazaga Campus, TR-34469 Istanbul, Turkey
关键词
iprodione removal; UV-C-activated persulfate; zero-valent iron-activated persulfate; zero-valent aluminium-activated persulfate; performance in simulated urban wastewater; DICARBOXIMIDE FUNGICIDE; HYDROXYL RADICALS; ACUTE TOXICITY; BISPHENOL-A; HUMAN URINE; DEGRADATION; PESTICIDES; SULFATE; PHOTODEGRADATION; DICHLOROANILINES;
D O I
10.3390/w13121679
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The degradation of iprodione (IPR), a once frequently used but recently banned dicarboximide fungicide, by UV-C light-, zero-valent iron- (ZVI), and zero-valent aluminium (ZVA)-activated persulfate (PS) oxidation processes was comparatively studied in distilled (pure) water (DW) and simulated, tertiary treated urban wastewater (SWW). The performance of PS-activated oxidation processes was examined by following IPR (2-10 mg/L) removal, PS (0.01-1.00 mM) consumption, metal ion release (for the two heterogeneous catalytic oxidation processes), dissolved organic carbon (DOC) removal as well as hydroxylated aromatic and low molecular weight aliphatic degradation products. The effect of pH and PS concentrations on IPR removal was examined in DW. While the experiments in DW highlighted the superior performance of UV-C/PS treatment (with 78% DOC removal after 120 min at pH = 6.2), the performance of UV-C/PS treatment decreased sharply (to 24% DOC removal after 120 min at pH = 6.8) in the complex wastewater matrix (in SWW). Complete IPR (in 20 min) and 40% DOC (in 120 min) removals were obtained with ZVI/PS treatment (1 g/L ZVI, 1.5 mM PS, pH = 3.0), which was the most effective oxidation process in SWW. The treatment performance was strongly influenced by the SWW constituents, and UV-C/PS treatment appeared to be the most sensitive to it.
引用
收藏
页数:19
相关论文
共 50 条
  • [1] Treatment of industrial contaminants with zero-valent iron- and zero-valent aluminium-activated persulfate: a case study with 3,5-dichlorophenol and 2,4-dichloroaniline
    Koba Ucun, Olga
    Montazeri, Bahareh
    Arslan Alaton, Idil
    Olmez Hanci, Tugba
    TURKISH JOURNAL OF CHEMISTRY, 2021, 45 (02) : 269 - +
  • [2] UV and Zero-Valent Iron (ZVI) Activated Continuous Flow Persulfate Oxidation of Municipal Wastewater
    Kanafin, Yerkanat N. N.
    Abdirova, Perizat
    Kanafina, Dinara
    Arkhangelsky, Elizabeth
    Kyzas, George Z. Z.
    Poulopoulos, Stavros G. G.
    CATALYSTS, 2023, 13 (01)
  • [3] Simultaneous removal of bisphenol A and phosphate in zero-valent iron activated persulfate oxidation process
    Zhao, Li
    Ji, Yuefei
    Kong, Deyang
    Lu, Junhe
    Zhou, Quansuo
    Yin, Xiaoming
    CHEMICAL ENGINEERING JOURNAL, 2016, 303 : 458 - 466
  • [4] Degradation of Tetracycline in Wastewater by Persulfate Activated by Sulfidated Nanometer Zero-valent Iron
    Ye, Qiuyue
    Hu, Zhengchun
    Wang, Ziyi
    Xu, Wen
    Zhao, Shiyi
    Deng, Xuying
    Guo, Minghao
    Guo, Na
    Liao, Bing
    Gongcheng Kexue Yu Jishu/Advanced Engineering Sciences, 2024, 56 (04): : 35 - 45
  • [5] Oxidation of phenol by persulfate activated by zero-valent iron-biochar composites
    Nguyen, Thi-Hai Anh
    Oh, Seok-Young
    CHEMICAL ENGINEERING COMMUNICATIONS, 2022, 209 (11) : 1542 - 1552
  • [6] Biochar-mediated oxidation of phenol by persulfate activated with zero-valent iron
    Thi-Hai Anh Nguyen
    Oh, Seok-Young
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2019, 258
  • [7] Biochar-mediated oxidation of phenol by persulfate activated with zero-valent iron
    Thi-Hai Anh Nguyen
    Oh, Seok-Young
    JOURNAL OF CHEMICAL TECHNOLOGY AND BIOTECHNOLOGY, 2019, 94 (12) : 3932 - 3940
  • [8] Advanced oxidation processes based on zero-valent aluminium for treating textile wastewater
    Khatri, Jayraj
    Nidheesh, P. V.
    Singh, S. Anantha
    Kumar, M. Suresh
    CHEMICAL ENGINEERING JOURNAL, 2018, 348 : 67 - 73
  • [9] Zero-valent iron (ZVI) activation of persulfate (PS) for oxidation of bentazon in water
    Wei, Xingya
    Gao, Naiyun
    Li, Changjun
    Deng, Yang
    Zhou, Shiqing
    Li, Lei
    CHEMICAL ENGINEERING JOURNAL, 2016, 285 : 660 - 670
  • [10] Simultaneous removal of chromium(VI) and tetracycline hydrochloride from simulated wastewater by nanoscale zero-valent iron/copper–activated persulfate
    Guangzhou Qu
    Rongjie Chu
    Hui Wang
    Tiecheng Wang
    Zengqiang Zhang
    Hong Qiang
    Dongli Liang
    Shibin Hu
    Environmental Science and Pollution Research, 2020, 27 : 40826 - 40836