Application of a 3D display system for biplane cerebral angiography

被引:0
|
作者
Ooe, Y [1 ]
Ishihara, K [1 ]
Otsuka, H [1 ]
Yamada, K [1 ]
Inoue, M [1 ]
机构
[1] Osaka Natl Hosp, Clin Res Inst, Chuo Ku, Osaka 540, Japan
关键词
biplane angiography; cerebral angiography; 3D display system; 3D reconstruction;
D O I
暂无
中图分类号
R-058 [];
学科分类号
摘要
To improve the total safety for the biplane cerebral angiographic examination we have developed a new three dimensional (3D) display system. By applying this system, shortening the examination rime and reducing the risk of infection and embolization were achieved. We added just one graphic-workstation far 3D reconstruction to an ordinary biplane digital-cine-angiography system. This system can process the images of angiogram extempore in a short time and display the run of arterial vessels to the examiner. Biplane images were taken from the digital-cine-angiography system into the workstation through a video display. Three dimensional positions were calculated and displayed on a CRT monitor. It took from 15 to 45 seconds for the calculation. This system could display instantly the run of arterial vessels from any angle by using the computer mouse. Our system doesn't disturb the examination but helps us to understand the run of the arterial vessels. This system was useful in cases where the arteries wound their way around or overlapped each other.
引用
收藏
页码:1013 / 1016
页数:4
相关论文
共 50 条
  • [1] Development of 3D display system for biplane cerebral angiography
    Ooe, Y
    Ishihara, K
    Nagakura, T
    Otsuka, H
    Inoue, M
    [J]. CAR '98 - COMPUTER ASSISTED RADIOLOGY AND SURGERY, 1998, 1165 : 962 - 962
  • [2] Development of a 3D display system for biplane cerebral angiography
    Ooe, Y
    Kusuoka, H
    Nakanishi, E
    Furukawa, S
    Etani, H
    Isaka, Y
    Imaizumi, M
    Nagakura, T
    Inoue, M
    [J]. IEEE-EMBS ASIA PACIFIC CONFERENCE ON BIOMEDICAL ENGINEERING - PROCEEDINGS, PTS 1 & 2, 2000, : 493 - 494
  • [3] Development of a 3D display system for biplane cerebral angiography, using a Personal Computer (PC) system
    Ooe, Y
    Ishihara, K
    Otsuka, H
    Yamada, K
    Inoue, M
    [J]. PROCEEDINGS OF THE 20TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 20, PTS 1-6: BIOMEDICAL ENGINEERING TOWARDS THE YEAR 2000 AND BEYOND, 1998, 20 : 544 - 547
  • [4] 3D Angiography Reconstruction Techniquefrom Biplane Projections
    Xia Shunren(Dept. of Life Science and Biomedical EngineeringZhejiang University
    [J]. Chinese Journal of Biomedical Engineering, 1997, (03) : 131 - 132
  • [5] 3D reconstruction of coronary artery using biplane angiography
    Law, AKW
    Zhu, H
    Chan, FHY
    [J]. PROCEEDINGS OF THE 25TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4: A NEW BEGINNING FOR HUMAN HEALTH, 2003, 25 : 533 - 536
  • [6] Registration of biplane angiography and intravascular ultrasound for 3D vessel reconstruction
    Weichert, F
    Wawro, M
    Müller, H
    Wilke, C
    [J]. METHODS OF INFORMATION IN MEDICINE, 2004, 43 (04) : 398 - 402
  • [7] BIPLANE STEREOSCOPIC CEREBRAL ANGIOGRAPHY
    STAUFFER, HM
    MURTAGH, F
    MOKROHISKY, JF
    PAUL, RE
    [J]. ACTA RADIOLOGICA, 1956, 46 (1-2) : 262 - 272
  • [8] Computer aided 3D display system and its application in 3D vision test
    Shen, XY
    Ma, L
    Hou, CP
    Wang, JN
    Tang, D
    Li, C
    [J]. DISPLAY DEVICES AND SYSTEMS II, 1998, 3560 : 139 - 145
  • [9] Determination of 3D vessel trees from biplane images for coronary angiography
    Hoffmann, KR
    Sen, A
    Lan, L
    Metz, CE
    Chua, KG
    Williams, BB
    Esthappan, J
    Fiebich, M
    Mazzucco, M
    Doi, K
    [J]. CAR '97 - COMPUTER ASSISTED RADIOLOGY AND SURGERY, 1997, 1134 : 162 - 165
  • [10] HoloVizio 3D display system
    Balogh, Tibor
    Kovacs, Peter Tamas
    Barsi, Attila
    [J]. 2007 3DTV CONFERENCE, 2007, : 17 - 20