Structural evaluation of all-GFRP cable-stayed footbridge after 20 years of service life

被引:7
|
作者
Gorski, Piotr [1 ]
Stankiewicz, Beata [1 ]
Tatara, Marcin [1 ]
机构
[1] Opole Univ Technol, Fac Civil Engn & Architecture, Dept Rd & Bridges, Katowicka 48 St, PL-45061 Opole, Poland
来源
STEEL AND COMPOSITE STRUCTURES | 2018年 / 29卷 / 04期
关键词
GFRP bridge structure; finite element analysis; free-decay vibration; dynamic characteristics; dynamic mechanical analysis; structural stiffness; PULTRUDED GFRP; CONCRETE BRIDGE; IDENTIFICATION; DURABILITY; BEHAVIOR; EXPOSURE; PANELS; FORCE;
D O I
10.12989/scs.2018.29.4.527
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The paper presents the study on a change in modal parameters and structural stiffness of cable-stayed Fiberline Bridge made entirely of Glass Fiber Reinforced Polymer (GFRP) composite used for 20 years in the fjord area of Kolding, Denmark. Due to this specific location the bridge structure was subjected to natural aging in harsh environmental conditions. The flexural properties of the pultruded GFRP profiles acquired from the analyzed footbridge in 1997 and 2012 were determined through three-point bending tests. It was found that the Young's modulus increased by approximately 9%. Moreover, the influence of the temperature on the storage and loss modulus of GFRP material acquired from the Fiberline Bridge was studied by the dynamic mechanical analysis. The good thermal stability in potential real temperatures was found. The natural vibration frequencies and mode shapes of the bridge for its original state were evaluated through the application of the Finite Element (FE) method. The initial FE model was created using the real geometrical and material data obtained from both the design data and flexural test results performed in 1997 for the intact composite GFRP material. Full scale experimental investigations of the free-decay response under human jumping for the experimental state were carried out applying accelerometers. Seven natural frequencies, corresponding mode shapes and damping ratios were identified. The numerical and experimental results were compared. Based on the difference in the fundamental natural frequency it was again confirmed that the structural stiffness of the bridge increased by about 9% after 20 years of service life. Data collected from this study were used to validate the assumed FE model. It can be concluded that the updated FE model accurately reproduces the dynamic behavior of the bridge and can be used as a proper baseline model for the long-term monitoring to evaluate the overall structural response under service loads. The obtained results provided a relevant data for the structural health monitoring of all-GFRP bridge.
引用
收藏
页码:527 / 544
页数:18
相关论文
共 38 条
  • [1] Vibration serviceability of all-GFRP cable-stayed footbridge under various service excitations
    Gorski, Piotr
    Tatara, Marcin
    Stankiewicz, Beata
    MEASUREMENT, 2021, 183
  • [2] Vibration serviceability of all-GFRP cable-stayed footbridge under various service excitations
    Górski, Piotr
    Tatara, Marcin
    Stankiewicz, Beata
    Measurement: Journal of the International Measurement Confederation, 2021, 183
  • [3] Modal parameter identification of all-GFRP composite cable-stayed footbridge in Denmark
    Gorski, Piotr
    Stankiewicz, Beata
    Tatara, Marcin
    DYNAMICS OF CIVIL ENGINEERING AND TRANSPORT STRUCTURES AND WIND ENGINEERING (DYN-WIND'2017), 2017, 107
  • [4] A theoretical and experimental evaluation of the modal properties of a cable-stayed footbridge
    Drygala, Izabela J.
    Dulinska, Joanna M.
    X INTERNATIONAL CONFERENCE ON STRUCTURAL DYNAMICS (EURODYN 2017), 2017, 199 : 2937 - 2942
  • [5] Assessment of the structural condition of a cable-stayed footbridge based on dynamic tests
    Nunes, Danilo de Santana
    de Brito, Jose Luis Vital
    Doz, Graciela Nora
    LATIN AMERICAN JOURNAL OF SOLIDS AND STRUCTURES, 2024, 21 (02)
  • [6] Evaluation on Vibration Serviceability of a Cable-stayed Footbridge through Field Measurement
    Cai, Hui
    Chen, Bo
    Xie, Weiping
    Zhao, Na
    ADVANCES IN ENVIRONMENTAL VIBRATION, 2011, : 568 - 574
  • [7] Concept and Preliminary Analysis of Novel Movable Structural System for Cable-Stayed Footbridge
    Zhang, Tianhao
    Kawaguchi, Ken'ichi
    Wu, Minger
    JOURNAL OF BRIDGE ENGINEERING, 2019, 24 (04)
  • [8] Structural behavior of cable-stayed bridges after cable failure
    Kim, Seungjun
    Kang, Young Jong
    STRUCTURAL ENGINEERING AND MECHANICS, 2016, 59 (06) : 1095 - 1120
  • [9] Dynamic tests for structural evaluation and repair of cable-stayed bridges
    Prato, CA
    Casas, JR
    Ceballos, MA
    Gerbaudo, CF
    ADVANCES IN STRUCTURAL DYNAMICS, VOLS I & II, 2000, 10 : 1077 - 1084
  • [10] Stay Cable Damage Detection and Structural Safety Evaluation for Cable-Stayed Bridge After Fire Exposure
    XU Zhao F.
    Chen Y.
    Li Y.
    Zhang J.
    Bridge Construction, 2024, 54 (02) : 48 - 56