Evaluation of brain perfusion SPECT using an easy Z-score imaging system (eZIS) as an adjunct to early-diagnosis of neurodegenerative diseases

被引:65
|
作者
Waragai, Masaaki
Yamada, Tatsuo
Matsuda, Hiroshi
机构
[1] JR Tokyo Gen Hosp, Div Neurol, Shibuya Ku, Tokyo 1518528, Japan
[2] Fukuoka Univ, Sch Med, Dept Internal Med 5, Fukuoka 8140180, Japan
[3] Saitama Med Univ Hosp, Dept Nucl Med, Saitama 3500495, Japan
关键词
SPECT; regional cerebral blood flow (rCBF); neurodegenerative disease; easy Z-score imaging system (eZIS);
D O I
10.1016/j.jns.2007.03.027
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
The eZIS allows computer-assisted statistical analysis of brain perfusion SPECT images. We evaluated the diagnostic value of brain perfusion SPECT using eZIS in patients with various neurodegenerative diseases at a very early stage, within one year from onset. Methods: SPECT using eZIS was performed for patients with Alzheimer disease (AD), dementia with Lewy bodies (DLB), frontotemporal dementia (FTD,), idiopathic Parkinson disease (PD) and vascular Parkinsonism (VP), multiple systemic atrophy of the cerebellar type (MSA-C), cortical cerebellar atrophy (CCA) and amyotrophic lateral sclerosis (ALS). Results: Decreased rCBF was observed in the posterior cingulate cortex, precuneus and parietal cortex in AD; in the frontal gyrus and insula in FTD; in the occipital lobe, precuneus gyrus and posterior cingulate cortex in DLB; in the striatum and the thalamus in VP; in the cerebellum in CCA; in the cerebellum and pons in MSA-C and in the frontal cortex including the central sulcus in ALS. Increased rCBF in the striatum, thalamus and cerebellar dentate nuclei were observed in PD. Conclusions: A specific rCBF pattern was observed for each disease using eZIS analysis, consistent with previous reports. Our results showed eZIS can be easily used as an adjunct to early-diagnosis of neurodegenerative diseases in any hospital. (C) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:57 / 64
页数:8
相关论文
共 25 条
  • [1] Two-Layer Appearance on Brain Perfusion SPECT in Idiopathic Normal Pressure Hydrocephalus: A Qualitative Analysis by Using Easy Z-Score Imaging System, eZIS
    Kobayashi, Seiju
    Tateno, Masaru
    Utsumi, Kumiko
    Takahashi, Akira
    Morii, Hidetoshi
    Saito, Toshikazu
    [J]. DEMENTIA AND GERIATRIC COGNITIVE DISORDERS, 2009, 28 (04) : 330 - 337
  • [2] Two-layer appearance on brain perfusion SPECT in idiopathic normal pressure hydrocephalus: A qualitative analysis by using easy Z-score imaging system, eZIS
    Kobayashi, Seiju
    Tateno, Masaru
    Utsumi, Kumiko
    Morii, Hidetoshi
    Saito, Toshikazu
    [J]. ASIA-PACIFIC PSYCHIATRY, 2012, 4 : 140 - 140
  • [3] The evaluation of brain perfusion SPECT using an easy Z-score imaging system in the mild cognitive impairment subjects with brain amyloid-β deposition
    Takemaru, Makoto
    Kimura, Noriyuki
    Abe, Yoshitake
    Goto, Megumi
    Matsubara, Etsuro
    [J]. CLINICAL NEUROLOGY AND NEUROSURGERY, 2017, 160 : 111 - 115
  • [4] Examination of volume change in anatomical standardization with the easy Z-score Imaging System (eZIS)
    Kimura, T.
    Matsuura, M.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2011, 38 : S445 - S445
  • [5] An easy Z-score imaging system for discrimination between very early Alzheimer's disease and controls using brain perfusion SPECT in a multicentre study
    Matsuda, Hiroshi
    Mizumura, Sunao
    Nagao, Takehiko
    Ota, Tsuneyoshi
    Iizuka, Tomomichi
    Nemoto, Kiyotaka
    Kimura, Michihiro
    Tateno, Amane
    Ishiwata, Akiko
    Kuji, Ichiei
    Arai, Heii
    Homma, Akira
    [J]. NUCLEAR MEDICINE COMMUNICATIONS, 2007, 28 (03) : 199 - 205
  • [6] THE FINDINGS OF NARCOLEPSY ON TC-99M ECD BRAIN PERFUSION SPECT AS ANALYZED BY EASY Z-SCORE IMAGING SYSTEM
    Lin, Wei
    Wei, Cheng Yu
    Matsuda, Hiroshi
    Hung, Guang Uei
    [J]. SLEEP, 2019, 42
  • [7] Evaluation of the difference-correction effect of the gamma camera systems used by easy Z-score Imaging System (eZIS) analysis
    Yamamoto, Yasushi
    Onoguchi, Masahisa
    Kawakami, Kazunori
    Haramoto, Masuo
    Wake, Rei
    Horiguchi, Jun
    Kitagaki, Hajime
    [J]. ANNALS OF NUCLEAR MEDICINE, 2014, 28 (03) : 263 - 275
  • [8] Evaluation of the difference-correction effect of the gamma camera systems used by easy Z-score Imaging System (eZIS) analysis
    Yasushi Yamamoto
    Masahisa Onoguchi
    Kazunori Kawakami
    Masuo Haramoto
    Rei Wake
    Jun Horiguchi
    Hajime Kitagaki
    [J]. Annals of Nuclear Medicine, 2014, 28 : 263 - 275
  • [9] Cerebral hypoperfusion in reversible cerebral vasoconstriction syndrome(RCVS): Single photon emission computed tomography (SPECT) analysis with an easy Z-score imaging system (eZIS)
    Iwata, M.
    Ogura, A.
    Inagaki, R.
    Furukawa, S.
    Suzuki, J.
    Nishida, S.
    Ito, Y.
    [J]. JOURNAL OF THE NEUROLOGICAL SCIENCES, 2017, 381 : 431 - 431
  • [10] Classification of cerebellar atrophy using voxel-based morphometry and SPECT with an easy Z-score imaging system
    Nanri, K.
    Koizumi, K.
    Mitoma, H.
    Taguchi, T.
    Takeguchi, M.
    Ishiko, T.
    Mizusawa, H.
    [J]. MOVEMENT DISORDERS, 2010, 25 (07) : S196 - S196