ETDRS-Fast: Implementing psychophysical adaptive methods to standardized visual acuity measurement with ETDRS charts

被引:6
|
作者
Camparini, M
Cassinari, P
Ferrigno, L
Macaluso, C
机构
[1] Univ Parma, Inst Ophthalmol, I-43100 Parma, Italy
[2] Ist Super Sanita, Epidemiol & Biostat Lab, I-00161 Rome, Italy
关键词
D O I
暂无
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. TO measure visual acuity (VA) on Early Treatment Diabetic Retinopathy Study (ETDRS) charts with a modified faster procedure (ETDRS-Fast), based on adaptive psychophysics methods and to assess the method's validity and reproducibility. METHODS. Whereas the standard method for measuring VA with the ETDRS charts requires that the subject read all the letters beginning with the top row, in the ETDRS-Fast procedure, the subject is asked to read only one letter per row until a mistake is made. Then, following simple rules, the examiner finds a row from which the subject can begin reading all the letters downward, thus making the method identical with the standard method near threshold. VA determination was performed twice with both methods in 57 subjects in two separate sessions to assess validity and reproducibility. RESULTS. In both sessions the correlation between the two procedures was high (intraclass correlation coefficient 0.95), confirming the validity of the ETDRS-Fast procedure. Reproducibility was good for both procedures, with intraclass correlation coefficients of 0.94 for the standard and 0.96 for the ETDRS-Fast method. The ETDRS-Fast procedure allowed a significantly shorter test duration (-30%; P < 0.0001). CONCLUSIONS. Adaptive procedures allow accurate and fast determination of psychophysical thresholds by reducing the number of stimulus presentations when the subject is far from threshold. In the ETDRS-Fast method a few simple rules applied to optotype chart reading allow adaptation to each patient's level of VA. The ETDRS-Fast procedure significantly reduces test time and still yields results that are as accurate as those obtained with the standard method.
引用
收藏
页码:1226 / 1231
页数:6
相关论文
共 26 条
  • [1] Efficient standardized visual acuity measurement with ETDRS charts by implementing adaptive psychophysical methods: the ETDRS-Fast procedure.
    Macaluso, C
    Cassinari, P
    Camparini, M
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2001, 42 (04) : S862 - S862
  • [2] C-Fast: standardized visual acuity measurement in children with Landolt-C "ETDRS-style" charts implementing adaptive psychophysical methods.
    Camparini, M
    Cassinari, P
    Ambrosoli, D
    Porta, R
    Macaluso, C
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2001, 42 (04) : S384 - S384
  • [3] Validation of Electronic Visual Acuity Measurement Against Standardised ETDRS Charts In Retinal Disease
    Jolly, Jasleen Kaur
    Juenemann, Kristin
    Boagey, Heather
    Moschandreas, Joanna
    Nadsady, Marie
    Bridge, Holly
    MacLaren, Robert E.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019, 60 (09)
  • [4] Repeatability and Concordance of Visual Acuity Measured with ETDRS Number, ETDRS Landolt C, and Original ETDRS Alphabet Charts in Normal Eyes or Eyes with Sight-threatening Conditions
    Chaikitmongkol, Voraporn
    Nanegrungsunk, Onnisa
    Patikulsila, Direk
    Ruamviboonsuk, Paisan
    Bressler, Neil
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)
  • [5] Validation of an automated-ETDRS near and intermediate visual acuity measurement
    Pang, Yi
    Sparschu, Lauren
    Nylin, Elyse
    [J]. CLINICAL AND EXPERIMENTAL OPTOMETRY, 2020, 103 (05) : 663 - 667
  • [6] Reproducibility of visual acuity measurement using the ETDRS chart in daily clinical practice
    Nicolas, C.
    Debellemaniere, G.
    Boissier, F.
    Girard, C.
    Schwartz, C.
    Delbosc, B.
    Saleh, M.
    [J]. JOURNAL FRANCAIS D OPHTALMOLOGIE, 2016, 39 (08): : 700 - 705
  • [7] Validation of a computerised logMAR visual acuity measurement system (COMPlog): comparison with ETDRS and the electronic ETDRS testing algorithm in adults and amblyopic children
    Laidlaw, D. A. H.
    Tailor, V.
    Shah, N.
    Atamian, S.
    Harcourt, C.
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 2008, 92 (02) : 241 - 244
  • [8] Age-related course of visual acuity obtained with ETDRS 2000 charts in persons with healthy eyes
    Radner, Wolfgang
    Benesch, Thomas
    [J]. GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2019, 257 (06) : 1295 - 1301
  • [9] Age-related course of visual acuity obtained with ETDRS 2000 charts in persons with healthy eyes
    Wolfgang Radner
    Thomas Benesch
    [J]. Graefe's Archive for Clinical and Experimental Ophthalmology, 2019, 257 : 1295 - 1301
  • [10] Comparison Between Visual Acuity Testing Using Snellen and Etdrs Charts in Patients With and Without Macular Disease
    Pellegrini, G. A.
    Bordon, A. F.
    Harasawa, M.
    d Silveira, L. Q. S.
    Afonso, V. C. C.
    Ramos, G. Z.
    Raskin, A.
    Moreira, C.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)