Reproducibility and repeatability of MRI-based body composition analysis

被引:39
|
作者
Borga, Magnus [1 ,2 ,3 ]
Ahlgren, Andre [3 ]
Romu, Thobias [3 ]
Widholm, Per [2 ,3 ,4 ]
Leinhard, Olof Dahlqvist [2 ,3 ,4 ]
West, Janne [1 ,2 ,3 ]
机构
[1] Linkoping Univ, Dept Biomed Engn, SE-58183 Linkoping, Sweden
[2] Linkoping Univ, Ctr Med Image Sci & Visualizat, Linkoping, Sweden
[3] AMRA Med AB, Linkoping, Sweden
[4] Linkoping Univ, Dept Hlth Med & Caring Sci, Linkoping, Sweden
基金
瑞典研究理事会;
关键词
body composition analysis; chemical shift encoded MRI; fat fraction; MRI; repeatability; reproducibility; water-fat imaging; INCIDENT CARDIOVASCULAR-DISEASE; SUBCUTANEOUS ADIPOSE-TISSUE; TEST-RETEST RELIABILITY; WHOLE-BODY; MUSCLE VOLUME; VISCERAL FAT; ABDOMINAL FAT; NORMAL-WEIGHT; MASS INDEX; QUANTIFICATION;
D O I
10.1002/mrm.28360
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose There is an absence of reproducibility studies on MRI-based body composition analysis in current literature. Therefore, the aim of this study was to investigate the between-scanner reproducibility and the repeatability of a method for MRI-based body composition analysis. Methods Eighteen healthy volunteers of varying body mass index and adiposity were each scanned twice on five different 1.5T and 3T scanners from three different vendors. Two-point Dixon neck-to knee images and two additional liver scans were acquired with similar protocols. Visceral adipose tissue (VAT) volume, abdominal subcutaneous adipose tissue (ASAT) volume, thigh muscle volume, and muscle fat infiltration (MFI) in the thigh muscle were measured. Liver proton density fat fraction (PDFF) was assessed using two different methods, the scanner vendor's 6-point method and an in-house 2-point method. Within-scanner test-retest repeatability and between-scanner reproducibility were calculated using analysis of variance. Results Repeatability coefficients were 13 centiliters (cl) (VAT), 24 cl (ASAT), 17 cl (total thigh muscle volume), 0.53% (MFI), and 1.27-1.37% for liver PDFF. Reproducibility coefficients were 24 cl (VAT), 42 cl (ASAT), 31 cl (total thigh muscle volume), 1.44% (MFI), and 2.37-2.40% for liver PDFF. Conclusion For all measures except MFI, the within-scanner repeatability explained much of the overall reproducibility. The two methods for measuring liver fat had similar reproducibility. This study showed that the investigated method eliminates effects due to scanner differences. The results can be used for power calculations in clinical studies or to better understand the scanner-induced variability in clinical applications.
引用
收藏
页码:3146 / 3156
页数:11
相关论文
共 50 条
  • [1] Repeatability and reproducibility of MRI-based radiomic features in cervical cancer
    Fiset, Sandra
    Welch, Mattea L.
    Weiss, Jessica
    Pintilie, Melania
    Conway, Jessica L.
    Milosevic, Michael
    Fyles, Anthony
    Traverso, Alberto
    Jaffra, David
    Metser, Ur
    Xie, Jason
    Han, Kathy
    [J]. RADIOTHERAPY AND ONCOLOGY, 2019, 135 : 107 - 114
  • [2] Precision of MRI-based body composition measurements of postmenopausal women
    West, Janne
    Romu, Thobias
    Thorell, Sofia
    Lindblom, Hanna
    Berin, Emilia
    Holm, Anna-Clara Spetz
    Astrand, Lotta Lindh
    Karlsson, Anette
    Borga, Magnus
    Hammar, Mats
    Leinhard, Olof Dahlqvist
    [J]. PLOS ONE, 2018, 13 (02):
  • [3] Repeatability of MRI-based diffusion measurements of oesophageal cancer
    Van Lier, A.
    Van Rossum, P. S. N.
    Meijer, J.
    Van den Berg, C. A. T.
    Philippens, M. E. P.
    Lagendijk, J. J. W.
    Van Vulpen, M.
    Lips, I. M.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S106 - S107
  • [4] Reproducibility of Diffusion MRI-Based Tractography in the Fetal Brain
    Xiao, Jiaxin
    Sun, Cong
    Chen, Ruike
    Zhao, Zhiyong
    Wang, Guangbin
    Wu, Dan
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2024,
  • [5] Reproducibility of μ-MRI-based trabecular bone structure measurement.
    Weening, RH
    Wehrli, FW
    Gomberg, BR
    Hwang, SN
    Song, H
    Wright, AC
    [J]. JOURNAL OF BONE AND MINERAL RESEARCH, 2001, 16 : S343 - S343
  • [6] Repeatability and reproducibility of ADC measurements: a prospective multicenter whole-body-MRI study
    Nicolas F. Michoux
    Jakub W. Ceranka
    Jef Vandemeulebroucke
    Frank Peeters
    Pierre Lu
    Julie Absil
    Perrine Triqueneaux
    Yan Liu
    Laurence Collette
    Inneke Willekens
    Carola Brussaard
    Olivier Debeir
    Stephan Hahn
    Hubert Raeymaekers
    Johan de Mey
    Thierry Metens
    Frédéric E. Lecouvet
    [J]. European Radiology, 2021, 31 : 4514 - 4527
  • [7] Repeatability and reproducibility of ADC measurements: a prospective multicenter whole-body-MRI study
    Michoux, Nicolas F.
    Ceranka, Jakub W.
    Vandemeulebroucke, Jef
    Peeters, Frank
    Lu, Pierre
    Absil, Julie
    Triqueneaux, Perrine
    Liu, Yan
    Collette, Laurence
    Willekens, Inneke
    Brussaard, Carola
    Debeir, Olivier
    Hahn, Stephan
    Raeymaekers, Hubert
    de Mey, Johan
    Metens, Thierry
    Lecouvet, Frederic E.
    [J]. EUROPEAN RADIOLOGY, 2021, 31 (07) : 4514 - 4527
  • [8] MRI-based vertebral bone quality score: relationship with age and reproducibility
    Daniel Liu
    Aamir Kadri
    Diego Hernando
    Neil Binkley
    Paul A. Anderson
    [J]. Osteoporosis International, 2023, 34 : 2077 - 2086
  • [9] MRI-based vertebral bone quality score: relationship with age and reproducibility
    Liu, Daniel
    Kadri, Aamir
    Hernando, Diego
    Binkley, Neil
    Anderson, Paul A.
    [J]. OSTEOPOROSIS INTERNATIONAL, 2023, 34 (12) : 2077 - 2086
  • [10] THE REPRODUCIBILITY AND REPEATABILITY OF THE WITS ANALYSIS
    HAYNES, S
    CHAU, MNY
    [J]. AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 1995, 107 (06) : 640 - 647