Analytical evaluation of the Dade Behring Dimension RxL automated N-terminal proBNP (NT-proBNP) method and comparison with the Roche Elecsys 2010

被引:38
|
作者
Di Serio, F [1 ]
Ruggieri, V [1 ]
Varraso, L [1 ]
De Sario, R [1 ]
Mastrorilli, A [1 ]
Pansini, N [1 ]
机构
[1] Policlin Bari, Unita Operat Patol Clin 1, Bari, Italy
关键词
brain natriuretic peptide (BNP); heart failure; natriuretic peptides; N-terminal proBNP (NTproBNP);
D O I
10.1515/CCLM.2005.217
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Methods to quantify B-type natriuretic peptide (BNP) and N-terminal-propeptide (NT-proBNP) in plasma or serum samples are well established. We assessed the analytical performance of the Dimension RxL NT-proBNP method (Dade-Behring). Evaluation of different sample types was carried out. Controls and heparin plasma pools were used to determine the detection limit, precision, and linearity. Sample stability and the effect of interfering substances on the NT-proBNP concentrations were evaluated. Agreement between Dimension RxL and Elecsys 2010 (Roche Diagnostics) NT-proBNP methods was assessed. The influence of age and sex on NT-proBNP concentrations was evaluated in healthy subjects. Heparin plasma should be the matrix of choice. The detection limit was 2.0 ng/L. The total imprecision was 2.6-3.6% for concentrations from 231 to 9471 ng/L; mean NT-proBNP concentrations of 21 and 15 ng/L were associated with coefficients of variation of 9.9% and 14.7%, respectively. The method was linear up to 32,650 ng/L. There was no effect of temperature, freeze-thaw cycles and interfering substances. A bias was detected when Dimension RxL and Elecsys 2010 NT-proBNP methods were compared. Age and sex were significantly and independently related to N proBNP concentrations. The Dimension RxL NT-proBNP method, like the Elecsys 2010, is suitable for routine use in the diagnosis of heart failure.
引用
收藏
页码:1263 / 1273
页数:11
相关论文
共 50 条
  • [1] Analytical evaluation of the Dade Behring Stratus CSN-terminal proBNP (NT-proBNP) method and comparison with the dimension RxL
    Di Serio, F.
    Ruggieri, V.
    De Sario, R.
    Varraso, L.
    Pansini, N.
    CLINICAL CHEMISTRY, 2006, 52 (06) : A125 - A125
  • [2] NT-PROBNP on Dimension®-HM (Dade Behring):: Evaluation of the analytical performance characteristics and correlation with Roche Elecsys assay
    Benoit, MO
    Dautezac, F
    Paul, JL
    CLINICA CHIMICA ACTA, 2005, 355 : S226 - S226
  • [3] Evaluation of the analytical performance characteristics of NT-proBNP immunoassay on Dimension® RxL-HM (Dade Behring)
    Benoit, MO
    Dautezac, F
    Taccoen, M
    Paul, JL
    ANNALES DE BIOLOGIE CLINIQUE, 2005, 63 (04) : 411 - 416
  • [4] NT-proBNP measurement on Immulite 2500® (DPC):: analytical performance and comparison with Roche Diagnostics and Dade-Behring NT-proBNP immunoassays
    Cauliez, B.
    Boucher, S.
    Duflo-Leroy, A.
    Lavoinne, A.
    ANNALES DE BIOLOGIE CLINIQUE, 2007, 65 (01) : 93 - 98
  • [5] Development of an automated immunoassay for NT-proBNP on the Dade Behring Dimension® clinical chemistry system
    Wei, T
    Tuhy, P
    Bantum, L
    Posey, A
    Miller, L
    Singh, P
    Duffy, J
    Pierson-Perry, J
    CLINICAL CHEMISTRY, 2004, 50 (06) : A13 - A14
  • [6] Comparison of Abbott AxSYM and Roche Elecsys 2010 for measurement of BNP and NT-proBNP
    Chien, Tzu-I
    Chen, Hui-hou
    Kao, Jau-Tsuen
    CLINICA CHIMICA ACTA, 2006, 369 (01) : 95 - 99
  • [7] Comparison of Abbott AxSYM and Roche elecsys 2010 for measurement of BNP and NT-proBNP
    Shih, Jessie
    Olson, Robert M.
    CLINICA CHIMICA ACTA, 2006, 373 (1-2) : 191 - 191
  • [8] Evaluation of NT-proBNP assay on the Roche Elecsys 1010 and 2010 analyzers.
    Yeo, KT
    Lavalley, K
    Tobias, SM
    Brough, TJ
    Putz, GR
    CLINICAL CHEMISTRY, 2003, 49 (06) : A67 - A67
  • [9] Preliminary evaluation of NT-proBNP determination on the Elecsys 2010 and 1010.
    Barnes, SC
    Gaze, DC
    Collinson, PO
    CLINICAL CHEMISTRY, 2001, 47 (06) : A207 - A207
  • [10] Analytical and clinical performance of the NT-proBNP assay on the Dade Behring Dimension® clinical chemistry system and the Stratus® CSSTAT Fluorometric Analyzer
    Christenson, RH
    Scott, MG
    Hock, KG
    Jones, HL
    Figgs, TR
    CLINICAL CHEMISTRY, 2005, 51 : A19 - A20