Removal of Cr(VI) and electricity production by constructed wetland combined with microbial fuel cell (CW-MFC): Influence of filler media

被引:37
|
作者
Mu, Chunxia [1 ]
Wang, Lin [1 ]
Wang, Li [2 ]
机构
[1] Ocean Univ China, Coll Environm Sci & Engn, Qingdao 266100, Peoples R China
[2] Harbin Inst Technol, Sch Energy Sci & Engn, Harbin 150001, Peoples R China
关键词
CW-MFC; Filler; Cr(VI) removal; Electricity production; Microbial community; WASTE-WATER TREATMENT; BIOELECTRICITY GENERATION; PERFORMANCE ASSESSMENT; HEXAVALENT CHROMIUM; MODIFIED ZEOLITE; REDUCTION; MECHANISMS; FEASIBILITY; MACROPHYTE; RESISTANCE;
D O I
10.1016/j.jclepro.2021.128860
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Due to the high mobility and toxicity of Cr(VI), it is of significance to develop a low-cost and effective method to treat Cr(VI) contained wastewater. Currently, constructed wetland combined with microbial fuel cell (CW-MFC) technique has exhibited the possibilities in Cr(VI) removal. However, the influence of filler media was still unclear. In this study, the up-flow CW-MFC systems with different fillers were constructed to investigate Cr(VI) removal and electricity generation, including bio-ceramic (CW-MFC1), zeolite (CW-MFC2), calcite (CW-MFC3), and volcanic rock (CW-MFC4). Cr(VI) absorption ability of fillers was negligible during the long operation period. Over 93% COD removal was observed in all systems, and Cr(VI) removal rate was as follow: CW-MFC4 (99.0%) > CW-MFC2 (95.5%) > CW-MFC3 (89.7%) > CW-MFC1 (72.2%). Most of Cr(VI) ions were converted to Cr(III) precipitation and immobilized in the anode layer, followed by the bottom layer. There was a competitive relationship between the bottom microbes and anode layer microbes. Bio-ceramic is easy to realize immobilization of microorganisms, which as filler (CW-MFC1) showed the lowest removal rate of Cr(VI) in CW-MFC1 system, due to superabundant organic matter consumed by microorganisms of filler layer weakening the action of anodic microbes. Besides, calcite with lower specific surface area and less porous structure than volcanic rock and zeolite was unbeneficial to microbial living, leading to bottom layer lower Cr(VI) removal in CW-MFC3. Both output voltage and maximum power density of CW-MFC system were as the following order: CW-MFC3 > CW-MFC 4 > CW-MFC2 > CW-MFC1. This was mainly because higher organic matter were consumed (higher COD removal rate) in anode layers, more electricity was generated by exoelectmgenic microbes. Therefore, volcanic rock as fillers was the best choice, which could maximize Cr(VI) removal (99.0%) and obtain the preferable electricity generation (0.595 +/- 0.019 V of output voltage, 0.462 W/m(3) of power density). In addition, microbial communities analysis indicated that microbial richness of cathode was higher than anode due to the long Cr(VI) stress, and Acetoanaerobium and Exiguobacterium were the dominant genera in anode and cathode, respectively.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Improving the Performance of Constructed Wetland Microbial Fuel Cell (CW-MFC) for Wastewater Treatment and Electricity Generation
    Abdulwahab, Yussur D.
    Mohammed, Alaa Kareem
    Abbas, Talib R.
    [J]. BAGHDAD SCIENCE JOURNAL, 2021, 18 (01) : 7 - 17
  • [2] Role of electrode materials on performance and microbial characteristics in the constructed wetland coupled microbial fuel cell (CW-MFC): A review
    Huang, Xiao
    Duan, Chongsen
    Duan, Weiyan
    Sun, Feiyun
    Cui, Hongwu
    Zhang, Shuai
    Chen, Xi
    [J]. JOURNAL OF CLEANER PRODUCTION, 2021, 301
  • [3] Effect of vegetation type on treatment performance and bioelectric production of constructed wetland modules combined with microbial fuel cell (CW-MFC) treating synthetic wastewater
    Çağdaş Saz
    Cengiz Türe
    Onur Can Türker
    Anıl Yakar
    [J]. Environmental Science and Pollution Research, 2018, 25 : 8777 - 8792
  • [4] Effect of vegetation type on treatment performance and bioelectric production of constructed wetland modules combined with microbial fuel cell (CW-MFC) treating synthetic wastewater
    Saz, Cagdas
    Ture, Cengiz
    Turker, Onur Can
    Yakar, Anil
    [J]. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2018, 25 (09) : 8777 - 8792
  • [5] The electrode strategy and its coordination mechanism in constructed wetland-microbial fuel cell (CW-MFC): a review
    An R.
    Guan J.
    Li G.
    Li Z.
    Sheng L.
    Bian H.
    Lu N.
    [J]. Carbon Research, 3 (1):
  • [6] Constructed wetland - Microbial fuel cell (CW-MFC) packed with suspended fillers to enhance denitrification with Acorus calamus biomass addition
    Tao, Mengni
    Kong, Yu
    Cao, Shiwei
    Jing, Zhaoqian
    Guan, Lin
    Jia, Qiusheng
    Li, Yu -You
    [J]. CHEMICAL ENGINEERING JOURNAL, 2024, 487
  • [7] Influence of Cr (VI) concentration on Cr (VI) reduction and electricity production in microbial fuel cell
    Zhang, Xiuling
    Liu, Yuanfeng
    Li, Congju
    [J]. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2021, 28 (38) : 54170 - 54176
  • [8] Influence of Cr (VI) concentration on Cr (VI) reduction and electricity production in microbial fuel cell
    Xiuling Zhang
    Yuanfeng Liu
    Congju Li
    [J]. Environmental Science and Pollution Research, 2021, 28 : 54170 - 54176
  • [9] Studies on Cr (VI) removal by constructed wetland integrated microbial fuel cell: Effect of electrodes
    Kumari, Divyani
    Dutta, Kasturi
    [J]. JOURNAL OF ENVIRONMENTAL CHEMICAL ENGINEERING, 2024, 12 (04):
  • [10] The new report of domestic wastewater treatment and bioelectricity generation using Dieffenbachia seguine constructed wetland coupling microbial fuel cell (CW-MFC)
    Chaijak, Pimprapa
    Sola, Phachirarat
    [J]. ARCHIVES OF ENVIRONMENTAL PROTECTION, 2023, 49 (01) : 57 - 62