Three-Axis Magnetometer Calibration Using Total Least Squares

被引:11
|
作者
Crassidis, John L. [1 ]
Cheng, Yang [2 ]
机构
[1] Univ Buffalo State Univ New York, Dept Mech & Aerosp Engn, Amherst, NY 14260 USA
[2] Mississippi State Univ, Dept Aerosp Engn, Mississippi State, MS 39762 USA
关键词
Attitude determination - Attitude independents - Calibration algorithm - Calibration parameters - Calibration problems - Least-squares approach - Real world situations - Three-axis magnetometer;
D O I
10.2514/1.G005305
中图分类号
V [航空、航天];
学科分类号
08 ; 0825 ;
摘要
In this paper attitude-independent three-axis magnetometer (TAM) sensor calibration algorithms are presented from a total least squares approach. One algorithm estimates biases only, whereas the other performs full calibration, which includes biases, scale factors, and nonorthogonality corrections. All calibration parameters are assumed to be constant. It is shown that the TAM calibration problem using a standard least squares point of view is statistically inconsistent because the effective measurement variance is a function of the calibration parameters. This inconsistency is overcome by using the total least squares formulation. The error covariance of the calibration parameters is also derived, which is shown to be equivalent to the standard least squares formation to within first-order terms. Also, the covariance of the measurement-to-estimate residual vector is derived, which cannot be accomplished using a standard least squares approach. This covariance is useful to quantify the effects of the measurement covariance for attitude determination in real-world situations. Both simulated and experimental results are shown to assess the performance of the TAM calibration algorithms, as well as the derived covariance expressions.
引用
收藏
页码:1410 / 1424
页数:15
相关论文
共 50 条
  • [1] Constrained Total Least Squares Algorithm Applied to Three-axis Magnetometer Calibration
    Wu, Zhitian
    Hu, Xiaoping
    Wu, Meiping
    ADVANCES IN MECHATRONICS AND CONTROL ENGINEERING, PTS 1-3, 2013, 278-280 : 968 - 973
  • [2] Calibration of vehicular three-axis magnetometer via truncated total least squares algorithm
    Zhang, Ying
    Yang, Ren-Nong
    Li, Ming-Yang
    Zuo, Jia-Liang
    Chen, Xing-Yi
    2015, China Ordnance Industry Corporation (36): : 427 - 432
  • [3] Constrained total least-squares calibration of three-axis magnetometer for vehicular applications
    Wu, Zhitian
    Hu, Xiaoping
    Wu, Meiping
    Cao, Juliang
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2013, 24 (09)
  • [4] Comment on 'Constrained total least-squares calibration of three-axis magnetometer for vehicular applications'
    Chang, Guobin
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2014, 25 (12)
  • [5] On Calibration of Three-Axis Magnetometer
    Wu, Yuanxin
    Shi, Wei
    IEEE SENSORS JOURNAL, 2015, 15 (11) : 6424 - 6431
  • [6] Spacecraft attitude determination and three-axis magnetometer calibration
    Huang, Lin
    Jing, Wu-Xing
    Yuhang Xuebao/Journal of Astronautics, 2008, 29 (03): : 854 - 859
  • [7] A Calibration Method of Three-Axis Magnetometer With Noise Suppression
    Song Zhongguo
    Zhang Jinsheng
    Zhang Xuehui
    Xi Xiaoli
    IEEE TRANSACTIONS ON MAGNETICS, 2014, 50 (11)
  • [8] Novel Calibration Algorithm for a Three-Axis Strapdown Magnetometer
    Liu, Yan Xia
    Li, Xi Sheng
    Zhang, Xiao Juan
    Feng, Yi Bo
    SENSORS, 2014, 14 (05): : 8485 - 8504
  • [9] Calibration of Three-Axis Magnetometer Using Stretching Particle Swarm Optimization Algorithm
    Wu, Zhitian
    Wu, Yuanxin
    Hu, Xiaoping
    Wu, Meiping
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2013, 62 (02) : 281 - 292
  • [10] Complete Calibration of Three-Axis Strapdown Magnetometer in Mounting Frame
    Ousaloo, H. S.
    Sharifi, G.
    Mahdian, J.
    Nodeh, M. T.
    IEEE SENSORS JOURNAL, 2017, 17 (23) : 7886 - 7893