Optimizing ventilation-perfusion lung scintigraphy:: Parting with planar imaging

被引:0
|
作者
Reinartz, P [1 ]
Schirp, U [1 ]
Zimny, M [1 ]
Sabri, O [1 ]
Nowak, B [1 ]
Schäfer, W [1 ]
Cremerius, U [1 ]
Büll, U [1 ]
机构
[1] Aachen Univ Technol, Univ Hosp, Dept Nucl Med, D-52074 Aachen, Germany
来源
NUKLEARMEDIZIN-NUCLEAR MEDICINE | 2001年 / 40卷 / 02期
关键词
single photon emission computed tomography; SPECT; pulmonary embolism; lung scintigraphy;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Aim of the study was to introduce and verify a ventilation-perfusion (V/Q) acquisition protocol that incorporates new developments in scintigraphy in order to allow for a more balanced comparison with other diagnostic procedures. Methods: In 103 patients suspect of having pulmonary embolism, V/Q scans were acquired exclusively with SPECT technique. Ventilation was done with ultrafine aerosol. Planar images in eight directions were reconstructed through addition of three consecutive SPECT projections. Three referees examined the scans in regard to type, localization, and extent of V/Q defects. Results: Using this protocol, significantly more defects, especially of subsegmental size, were detected (p <0.01). Sensitivity, and diagnostic accuracy were also significantly improved (p <0.01) to 0.96, and 0.99, respectively. Furthermore, kappa values were increased up to 0.82 - a relevant enhancement in the ability to precisely localize V/Q defects. Conclusion: In conclusion this protocol provides high-resolution tomographic scans as well as high-quality planer images within a short acquisition time. Due to the significant increase in lesion detection, sensitivity, diagnostic accuracy, and anatomical localization of defects, it is a substantial improvement in the diagnosis of pulmonary embolism that will put V/Q scintigraphy on a par with other tomographic methods.
引用
收藏
页码:38 / 43
页数:6
相关论文
共 50 条
  • [1] SPECT/CT imaging of lung perfusion in the diagnosis of pulmonary embolism: Comparison with planar ventilation-perfusion lung scintigraphy
    Revel, C.
    Poisson, T.
    Revel, A.
    Daragon, N.
    Grandpierre, S.
    Netter, F.
    Scigliano, S.
    Djaballah, W.
    Olivier, P.
    Karcher, G.
    Marie, P. -Y.
    [J]. MEDECINE NUCLEAIRE-IMAGERIE FONCTIONNELLE ET METABOLIQUE, 2008, 32 (06): : 313 - 322
  • [2] VENTILATION-PERFUSION SCINTIGRAPHY
    WATERS, W
    [J]. NUCLEAR MEDICINE-NUKLEARMEDIZIN, 1987, 26 (03): : 111 - 119
  • [3] VENTILATION-PERFUSION MISMATCH - LUNG IMAGING
    WOOD, MJ
    [J]. CLINICAL NUCLEAR MEDICINE, 1983, 8 (04) : 181 - 181
  • [4] VENTILATION-PERFUSION MISMATCH - LUNG IMAGING
    DATZ, FL
    [J]. SEMINARS IN NUCLEAR MEDICINE, 1980, 10 (02) : 193 - 194
  • [5] OBSERVER VARIATION IN THE INTERPRETATION OF VENTILATION-PERFUSION LUNG SCINTIGRAPHY
    NIELSEN, HK
    HUSTED, SE
    KRUSELL, LR
    CHARLES, P
    FASTING, H
    HANSEN, HH
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1994, 21 (02): : 103 - 107
  • [6] CLINICAL VENTILATION-PERFUSION SCINTIGRAPHY
    FAZIO, F
    WOLLMER, P
    [J]. CLINICAL PHYSIOLOGY, 1981, 1 (04): : 323 - 337
  • [7] VENTILATION-PERFUSION SCINTIGRAPHY IN PNEUMOLOGY
    HUTTEMANN, U
    [J]. NUCLEAR MEDICINE-NUKLEARMEDIZIN, 1987, 26 (03): : 108 - 110
  • [8] How to use a gestalt interpretation for ventilation-perfusion lung scintigraphy
    Hagen, PJ
    Hartmann, LJC
    Hoekstra, OS
    Stokkel, MPM
    Teule, GJJ
    Prins, MH
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2002, 43 (10): : 1317 - 1323
  • [9] Contribution of CT scan to the performance of lung ventilation-perfusion scintigraphy
    Pilloy, W. J. G. E.
    Lens, V.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2009, 36 : S463 - S463
  • [10] VENTILATION-PERFUSION SCINTIGRAPHY IN AN ADULT WITH CONGENITAL UNILATERAL HYPERLUCENT LUNG
    WEGENER, WA
    VELCHIK, MG
    [J]. CLINICAL NUCLEAR MEDICINE, 1990, 15 (10) : 683 - 687