Sirolimus-eluting stents versus standard stents in patients with stenosis in a native coronary artery

被引:3259
|
作者
Moses, JW
Leon, MB
Popma, JJ
Fitzgerald, PJ
Holmes, DR
O'Shaughnessy, C
Caputo, RP
Kereiakes, DJ
Williams, DO
Teirstein, PS
Jaeger, JL
Kuntz, RE
机构
[1] Lenox Hill Heart & Vasc Inst New York, New York, NY USA
[2] Brigham & Womens Hosp, Boston, MA 02115 USA
[3] Stanford Univ, Med Ctr, Stanford, CA 94305 USA
[4] Mayo Clin & Mayo Fdn, Rochester, MN 55905 USA
[5] N Ohio Heart Ctr, Elyria, OH USA
[6] St Josephs Hosp, Syracuse, NY USA
[7] Christ Hosp Lindner Res Ctr, Cincinnati, OH USA
[8] Rhode Isl Hosp, Providence, RI USA
[9] Scripps Clin, La Jolla, CA USA
[10] Cordis, Warren, NJ USA
来源
NEW ENGLAND JOURNAL OF MEDICINE | 2003年 / 349卷 / 14期
关键词
D O I
10.1056/NEJMoa035071
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: Preliminary reports of studies involving simple coronary lesions indicate that a sirolimus-eluting stent significantly reduces the risk of restenosis after percutaneous coronary revascularization. METHODS: We conducted a randomized, double-blind trial comparing a sirolimus-eluting stent with a standard stent in 1058 patients at 53 centers in the United States who had a newly diagnosed lesion in a native coronary artery. The coronary disease in these patients was complex because of the frequent presence of diabetes (in 26 percent of patients), the high percentage of patients with longer lesions (mean, 14.4 mm), and small vessels (mean, 2.80 mm). The primary end point was failure of the target vessel (a composite of death from cardiac causes, myocardial infarction, and repeated percutaneous or surgical revascularization of the target vessel) within 270 days. RESULTS: The rate of failure of the target vessel was reduced from 21.0 percent with a standard stent to 8.6 percent with a sirolimus-eluting stent (P<0.001) -- a reduction that was driven largely by a decrease in the frequency of the need for revascularization of the target lesion (16.6 percent in the standard-stent group vs. 4.1 percent in the sirolimus-stent group, P<0.001). The frequency of neointimal hyperplasia within the stent was also decreased in the group that received sirolimus-eluting stents, as assessed by both angiography and intravascular ultrasonography. Subgroup analyses revealed a reduction in the rates of angiographic restenosis and target-lesion revascularization in all subgroups examined. CONCLUSIONS: In this randomized clinical trial involving patients with complex coronary lesions, the use of a sirolimus-eluting stent had a consistent treatment effect, reducing the rates of restenosis and associated clinical events in all subgroups analyzed.
引用
下载
收藏
页码:1315 / 1323
页数:9
相关论文
共 50 条
  • [2] Sirolimus- versus paclitaxel-eluting stents in patients with stenosis in a native coronary artery
    Doggrell, SA
    EXPERT OPINION ON PHARMACOTHERAPY, 2004, 5 (06) : 1431 - 1434
  • [3] A comparison of clinical outcomes of Chinese sirolimus-eluting stents versus foreign sirolimus-eluting stents for the treatment of coronary artery disease
    M. Yu
    Y.-J. Zhou
    Z.-J. Wang
    D.-M. Shi
    Y.-Y. Liu
    Y.-X. Zhao
    Y.-H. Guo
    W.-J. Cheng
    Y.-P. Li
    H.-Y. Ma
    Netherlands Heart Journal, 2011, 19 : 418 - 422
  • [4] A comparison of clinical outcomes of Chinese sirolimus-eluting stents versus foreign sirolimus-eluting stents for the treatment of coronary artery disease
    Yu, M.
    Zhou, Y-J
    Wang, Z-J
    Shi, D-M
    Liu, Y-Y
    Zhao, Y-X
    Guo, Y-H
    Cheng, W-J
    Li, Y-P
    Ma, H-Y
    NETHERLANDS HEART JOURNAL, 2011, 19 (10) : 418 - 422
  • [5] Sirolimus-eluting stents versus Paclitaxel-eluting stents in the treatment of coronary artery disease in patients with diabetes mellitus
    Kuchulakanti, Pramod K.
    Chu, William W.
    Torguson, Rebecca
    Clavijo, Leonardo
    Wolfram, Roswitha
    Mishra, Slindeep
    Xue, Zhenyi
    Gevorkian, Natalie
    Suddath, William O.
    Satler, Lowell F.
    Kent, Kenneth M.
    Pichard, Augusto D.
    Waksman, Ron
    AMERICAN JOURNAL OF CARDIOLOGY, 2006, 98 (02): : 187 - 192
  • [6] Sirolimus-eluting coronary stents
    Mack, MJ
    NEW ENGLAND JOURNAL OF MEDICINE, 2004, 350 (04): : 413 - 413
  • [7] Sirolimus-eluting coronary stents
    Sharma, S
    Bhambi, B
    Nyitray, W
    NEW ENGLAND JOURNAL OF MEDICINE, 2002, 347 (16): : 1285 - 1285
  • [8] Kissing sirolimus-eluting stents for the treatment of left main coronary artery stenosis
    Cox, N
    Rogers, C
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2004, 61 (02) : 206 - 210
  • [9] Paclitaxel-eluting stents versus sirolimus-eluting stents in treatment of coronary vessels
    Kate Matthews
    Nature Clinical Practice Cardiovascular Medicine, 2006, 3 (5): : 236 - 236