Data Transmission in Implantable Biomedical Microsystems by Pulse Harmonic Modulation: A New Structure

被引:0
|
作者
Amiri, Parviz [1 ]
Zinaty, Mohamad [1 ]
机构
[1] Shahid Rajaee Teacher Training Univ, Dept Elect Engn, Tehran, Iran
来源
2014 21th Iranian Conference on Biomedical Engineering (ICBME) | 2014年
关键词
Implantable Biomedical Microsystems; inductive link; intersymbol interference; Pulse Harmonic Modulation; telemetry;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
For data transmission from the Implantable Biomedical Microsystems (IBM) to outside the body by Pulse Harmonic Modulation (PHM), two narrow pulses with appropriate timing are used so as to increase the data rate and decrease the InterSymbol Interference (ISI). In this paper, a new structure based on clock width modification and its edge detection has been designed to generate pulses. To control the timing interval between the two pulses, one quantity is used, which is the advantage of this structure over the technology by ADS and HSPICE software, data transmission rate reaches 20 Mbps.
引用
收藏
页码:206 / 210
页数:5
相关论文
共 48 条
  • [1] An Enhancement in Data Transmission in Biomedical Implantable Microsystems: Uni-Pulse Harmonic Modulation
    Amiri, Parviz
    Zinaty, Mohamad
    2015 23RD IRANIAN CONFERENCE ON ELECTRICAL ENGINEERING (ICEE), 2015, : 27 - 31
  • [2] Implantable Biomedical Microsystems: A New Graduate Course in Biomedical Circuits and Systems
    Sodagar, Amir M.
    IEEE TRANSACTIONS ON EDUCATION, 2014, 57 (01) : 48 - 53
  • [3] Implantable Biomedical Microsystems: A New Graduate Course in Biomedical Circuits and Systems
    Sodagar, Amir M.
    2012 IEEE BIOMEDICAL CIRCUITS AND SYSTEMS CONFERENCE (BIOCAS): INTELLIGENT BIOMEDICAL ELECTRONICS AND SYSTEM FOR BETTER LIFE AND BETTER ENVIRONMENT, 2012, : 13 - 16
  • [4] A High-Data-Rate Area-Efficient Uni-Pulse Harmonic Modulation Transmitter for Implantable Neural Recording Microsystems
    Zinaty, Mohammad
    Amiri, Parviz
    Maghami, Mohammad Hossein
    JOURNAL OF CIRCUITS SYSTEMS AND COMPUTERS, 2020, 29 (04)
  • [5] High-Rate Ultrasonic Link for Data Telemetry to Implantable Biomedical Microsystems Using Pulse Excitation
    Keramatzadeh, Keivan
    Sodagar, Amir M.
    2018 IEEE LIFE SCIENCES CONFERENCE (LSC), 2018, : 17 - 20
  • [6] Capacitive Coupling for Power and Data Telemetry to Implantable Biomedical Microsystems
    Sodagar, Amir M.
    Amiri, Parviz
    2009 4TH INTERNATIONAL IEEE/EMBS CONFERENCE ON NEURAL ENGINEERING, 2009, : 404 - +
  • [7] Pulse-Based, Multi-Beam Optical Link for Data Telemetry to Implantable Biomedical Microsystems
    Alizadeh, Hanif
    Koolivand, Yarallah
    Sodagar, Amir M.
    2022 20TH IEEE INTERREGIONAL NEWCAS CONFERENCE (NEWCAS), 2022, : 529 - 532
  • [8] Data transmission for implantable microsystems using magnetic coupling
    Ahmadian, M
    Flynn, BW
    Murray, AF
    Cumming, DRS
    IEE PROCEEDINGS-COMMUNICATIONS, 2005, 152 (02): : 247 - 250
  • [9] Single-Pulse Harmonic Modulation for Short Range Biomedical Inductive Data Transfer
    Schormans, Matthew
    Valente, Virgilio
    Demosthenous, Andreas
    2017 IEEE BIOMEDICAL CIRCUITS AND SYSTEMS CONFERENCE (BIOCAS), 2017,
  • [10] Wideband Near-Field Data Transmission Using Pulse Harmonic Modulation
    Inanlou, Farzad
    Ghovanloo, Maysam
    IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS I-REGULAR PAPERS, 2011, 58 (01) : 186 - 195