The Noncoronary Cusp as a Site for Successful Ablation of Accessory Pathways: Electrogram Characteristics in Three Cases

被引:17
|
作者
Suleiman, Mahmoud [3 ]
Brady, Peter A.
Asirvatham, Samuel J. [1 ,2 ]
Friedman, Paul A.
Munger, Thomas M.
机构
[1] Mayo Clin, Coll Med, Dept Internal Med, Div Cardiovasc Dis, Rochester, MN 55905 USA
[2] Mayo Clin, Coll Med, Dept Pediat & Adolescent Med, Div Pediat Cardiol, Rochester, MN 55905 USA
[3] Rambam Hlth Care Campus, Dept Cardiol, Haifa, Israel
关键词
accessory pathway; aortic valve; noncoronary cusp; supravalvar; SVT; WPW; PARKINSON-WHITE-SYNDROME; RIGHT ATRIAL APPENDAGE; CATHETER ABLATION; CORRELATIVE ANATOMY; RIGHT VENTRICLE; AORTIC-VALVE; ELECTROPHYSIOLOGIST; CRYOABLATION; TACHYCARDIA; CONNECTION;
D O I
10.1111/j.1540-8167.2010.01811.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Noncoronary Cusp Accessory Pathway Ablation. Radiofrequency ablation is the treatment of choice to cure symptomatic patients with atrioventricular accessory pathways (APs). Septal APs are challenging because of the proximity of the normal conduction system. In some patients, despite aggressive lesion creation on the right anteroseptal region pathway, ablation is unsuccessful. We report 3 cases where the successful ablation site was in the noncoronary cusp of the aortic valve and discuss possible defining features of this variant of septal APs and an approach for successful ablation. (J Cardiovasc Electrophysiol, Vol. 22, pp. 203-209, February 2011).
引用
收藏
页码:203 / 209
页数:7
相关论文
共 50 条
  • [1] Unipolar electrogram characteristics predictive of successful radiofrequency catheter ablation of accessory pathways
    Barlow, MA
    Klein, GJ
    Simpson, CS
    Murgatroyd, FD
    Yee, R
    Krahn, AD
    Skanes, AC
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2000, 11 (02) : 146 - 154
  • [2] Successful catheter ablation of accessory pathway from noncoronary cusp of aorta: an alternative approach
    Kihcaslan, Fethi
    Uz, Omer
    Isilak, Zafer
    Tokatli, Alptug
    TURK KARDIYOLOJI DERNEGI ARSIVI-ARCHIVES OF THE TURKISH SOCIETY OF CARDIOLOGY, 2012, 40 (06): : 540 - 543
  • [3] ANALYSIS OF LOCAL ELECTROGRAM CHARACTERISTICS CORRELATED WITH SUCCESSFUL RADIOFREQUENCY CATHETER ABLATION OF ACCESSORY ATRIOVENTRICULAR PATHWAYS
    SILKA, MJ
    KRON, J
    HALPERIN, BD
    GRIFFITH, K
    CRANDALL, B
    OLIVER, RP
    WALANCE, CG
    MCANULTY, JH
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1992, 15 (07): : 1000 - 1007
  • [4] Electrogram patterns associated with successful radiofrequency ablation of accessory pathways in children
    Schwartz, SM
    Dick, M
    Dorostkar, PC
    Serwer, GA
    LeRoy, S
    PEDIATRIC CARDIOLOGY, 1996, 17 (03) : 137 - 142
  • [5] ELECTROGRAM PATTERNS PREDICTIVE OF SUCCESSFUL RADIOFREQUENCY CATHETER ABLATION OF ACCESSORY PATHWAYS
    HAISSAGUERRE, M
    FISCHER, B
    WARIN, JF
    DARTIGUES, JF
    LEMETAYER, P
    EGLOFF, P
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1992, 15 (11): : 2138 - 2145
  • [6] CHARACTERISTICS OF LOCAL ELECTROGRAM PREDICTING SUCCESSFUL TRANSCATHETER RADIOFREQUENCY ABLATION OF LEFT-SIDED ACCESSORY PATHWAYS
    XU, C
    BORGGREFE, M
    SHENASA, M
    HAVERKAMP, W
    HINDRICKS, G
    BREITHARDT, G
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1992, 20 (03) : 656 - 665
  • [7] Successful cryoablation in the noncoronary aortic cusp for a left anteroseptal accessory pathway
    Suleiman, Mahmoud
    Powell, Brian D.
    Munger, Thomas M.
    Asirvatham, Samuel J.
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2008, 23 (03) : 205 - 211
  • [8] RADIOFREQUENCY ABLATION OF ACCESSORY ATRIOVENTRICULAR PATHWAYS - PREDICTIVE VALUE OF LOCAL ELECTROGRAM CHARACTERISTICS FOR THE IDENTIFICATION OF SUCCESSFUL TARGET SITES
    BASHIR, Y
    HEALD, SC
    KATRITSIS, D
    HAMMOUDA, M
    CAMM, AJ
    WARD, DE
    BRITISH HEART JOURNAL, 1993, 69 (04): : 315 - 321
  • [9] Successful cryoablation in the noncoronary aortic cusp for a left anteroseptal accessory pathway
    Mahmoud Suleiman
    Brian D. Powell
    Thomas M. Munger
    Samuel J. Asirvatham
    Journal of Interventional Cardiac Electrophysiology, 2008, 23 : 205 - 211
  • [10] ELECTROGRAM PATTERNS PREDICTIVE OF SUCCESSFUL CATHETER ABLATION OF ACCESSORY PATHWAYS - VALUE OF UNIPOLAR RECORDING MODE
    HAISSAGUERRE, M
    DARTIGUES, JF
    WARIN, JF
    LEMETAYER, P
    MONTSERRAT, P
    SALAMON, R
    CIRCULATION, 1991, 84 (01) : 188 - 202