Optimal plate fixation of distal femoral fractures in the presence of a well fixed cemented hip arthroplasty femoral stem

被引:3
|
作者
Kempthorne, Josh [1 ]
Kieser, David C. [1 ]
Walker, Cameron G. [2 ]
机构
[1] Univ Otago, Dept Orthopaed Surg & Musculoskeletal Med, Christchurch, New Zealand
[2] Univ Auckland, Dept Engn Sci, Auckland, New Zealand
关键词
Cement; fracture; hip; peri-prosthetic; TOTAL KNEE ARTHROPLASTY; PERIPROSTHETIC FRACTURES; FEMUR FRACTURE; EPIDEMIOLOGY; VANCOUVER;
D O I
10.1177/1120700018760243
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction: The requirement for lateral plate fixation in the presence of a hip arthroplasty stem is increasing, yet the optimal plate construct necessary to reduce inter-prosthetic strain and prevent subsequent fractures is unknown. Therefore, the purpose of this study was to determine the optimal position of a lateral femoral plate in relation to a femoral stem. Methods: We used 4th Generation Composite Sawbones (R), a collarless polished cemented femoral stem and a broad Peri-loc (TM) plate with varying overlap of the stem. Each construct was subjected to torsion, axial compression and 3-point lateral bending, with the strain measured at the tip of the femoral stem and the force-to-failure recorded. Results: In all three loading directions a plate, which extended at least two shaft diameters proximal to the tip of the stem, experienced the lowest strain (p < 0.001). Constructs with no overlap, and particularly those with a small gap between the tip of the stem and the proximal extent of the plate experienced the highest strain (p < 0.001). This high strain resulted in lower forces required to cause fracture in the clinically significant scenarios of femoral torsion and lateral bending. Conclusions: Optimal plate fixation is achieved by extending a lateral femoral plate at least two shaft diameters proximal to the tip of the stem and using a spread of proximal screws. Distal fixation increases the strain experienced at the tip of the stem and higher strains are noted the smaller the gap between the proximal extent of the femoral plate and the tip of stem.
引用
收藏
页码:657 / 662
页数:6
相关论文
共 50 条
  • [1] Fixation of Periprosthetic Femoral Shaft Fractures Adjacent to a Well-Fixed Femoral Stem With Reversed Distal Femoral Locking Plate
    Ebraheim, Nabil A.
    Gomez, Carlos
    Ramineni, Satheesh K.
    Liu, Jiayong
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2009, 66 (04): : 1152 - 1157
  • [2] Challenges of Plate Fixation for Vancouver Type-C fractures after a Well-fixed Hip Arthroplasty Femoral Stem
    Ganji, Reza
    ARCHIVES OF BONE AND JOINT SURGERY-ABJS, 2019, 7 (06): : 571 - 572
  • [3] The Mennen femoral plate for fixation of periprosthetic femoral fractures following hip arthroplasty
    Ahuja, S
    Chatterji, S
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2002, 33 (01): : 47 - 50
  • [4] Revisiting Cemented Femoral Fixation in Hip Arthroplasty
    Khanuja, Harpal S.
    Mekkawy, Kevin L.
    MacMahon, Aoife
    McDaniel, Claire M.
    Allen, Donald A.
    Moskal, Joseph T.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2022, 104 (11): : 1024 - 1033
  • [5] Cemented vs uncemented fixation in osteoporotic femoral neck fractures treated with hip arthroplasty
    Giannini, S
    Moroni, A
    Pegreffi, F
    Romagnoli, M
    Vannini, F
    OSTEOPOROSIS INTERNATIONAL, 2002, 13 : S19 - S19
  • [6] Mennen plate fixation for fractures of the femoral shaft after ipsilateral hip arthroplasty
    Uchio, Y
    Shu, N
    Nishikawa, U
    Takata, K
    Ochi, M
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 1997, 42 (06): : 1157 - 1160
  • [7] Distal Femoral Locking Compression Plate Fixation in Distal Femoral Fractures: Early Results
    Yeap, E. J.
    Deepak, A. S.
    MALAYSIAN ORTHOPAEDIC JOURNAL, 2007, 1 (01) : 12 - 17
  • [8] Proximal and distal femoral centralizers in modern cemented hip arthroplasty
    Goldberg, BA
    Al-Habbal, G
    Noble, PC
    Paravic, M
    Liebs, TR
    Tullos, HS
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1998, (349) : 163 - 173
  • [9] CEMENTED COMPARED WITH UNCEMENTED FEMORAL FIXATION IN THE ARTHROPLASTY TREATMENT OF DISPLACED FEMORAL NECK FRACTURES
    Chen, Kevin K.
    Nayyar, Samir
    Davidovitch, Roy I.
    Vigdorchik, Jonathan M.
    Iorio, Richard
    Macaulay, William
    JBJS REVIEWS, 2018, 6 (04)
  • [10] Locking attachment plate fixation around a well-fixed stem in periprosthetic femoral shaft fractures
    Min Bom Kim
    Jae-Woo Cho
    Young Ho Lee
    Won-Yong Shon
    Jung Wee Park
    Jinil Kim
    Jong-Keon Oh
    Archives of Orthopaedic and Trauma Surgery, 2017, 137 : 1193 - 1200