Axial length shortening after orthokeratology and its relationship with myopic control

被引:13
|
作者
Wang, Anken [1 ]
Yang, Chenhao [1 ]
Shen, Li [1 ]
Wang, Jiaying [1 ]
Zhang, Zhehuan [1 ]
Yang, Weiming [1 ]
机构
[1] Fudan Univ, Dept Ophthalmol, Childrens Hosp, Shanghai, Peoples R China
关键词
Myopia; Orthokeratology; Axial length; Myopia control; CHOROIDAL THICKNESS; OVERNIGHT ORTHOKERATOLOGY; LENS WEAR; CHILDREN; PROGRESSION; ELONGATION; CORNEAL; ASTIGMATISM; DIAMETER;
D O I
10.1186/s12886-022-02461-4
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose To determine the pattern of axial variation in subjects with initial shortened axial length during the entire period of orthokeratology and to discuss the possibility of shortened AL after one month of orthokeratology becoming a predictor of myopia control. Method This study retrospectively included 106 children with myopia aged 8 to 14 wearing OK lenses. Fifty-four eyes with shortened axial length (AL) at the first-month visit were enrolled in the axial length shortening (ALS) group, and fifty-two eyes without shortened AL were enrolled in the no axial length shortening (NALS) group. Axial length and refractive error at baseline and within the entire period of orthokeratology (20 months), including fitting, washout period and re-wear, were measured. Eighty-five children who started wearing single vision spectacle were also included as a control group. Results In the ALS group, AL became longer after shortening and slowly exceeded baseline; afterward, AL experienced a rebound during the washout period and shortened again if OK lenses were re-worn. After washout period, significant difference in AL (ALS:0.28 +/- 0.19 mm, NALS: 0.52 +/- 0.17 mm) and spherical equivalent (ALS:-0.43 +/- 0.44D, NALS:-0.91 +/- 0.40D) between the two groups were found(P<0.05). The changes in AL and SE were both significantly correlated with the changes in AL at the first-month visit (P<0.05). Conclusion After AL is shortened in the initial stage of orthokeratology, it will experience a rapid rebound during the washout period, and the shortening can reappear when re-wearing OK lenses. Hence, the evaluation of orthokeratology will be more objective and accurate after the wash-out period. In addition, the existence and degree of axial shortening can be used as a predictor of long-term myopia development.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Axial length shortening after orthokeratology and its relationship with myopic control
    Anken Wang
    Chenhao Yang
    Li Shen
    Jiaying Wang
    Zhehuan Zhang
    Weiming Yang
    [J]. BMC Ophthalmology, 22
  • [2] Axial Length Control Is Associated With a Choroidal Thickness Increase in Myopic Adolescents After Orthokeratology
    Wang, Zhiqian
    Chen, Jingyi
    Kang, Jingxiong
    Niu, Tongtong
    Guo, Lei
    Fan, Liying
    [J]. EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2023, 49 (12): : 512 - 520
  • [3] The relationship between baseline axial length and axial elongation in myopic children undergoing orthokeratology
    Lin, Weiping
    Li, Na
    Lu, Kunpeng
    Li, Zhaochun
    Zhuo, Xiaohua
    Wei, Ruihua
    [J]. OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2023, 43 (01) : 122 - 131
  • [4] Effects of orthokeratology on axial length growth in myopic anisometropes
    Chen, Zhi
    Zhou, Jiaqi
    Qu, Xiaomei
    Zhou, Xingtao
    Xue, Feng
    [J]. CONTACT LENS & ANTERIOR EYE, 2018, 41 (03): : 263 - 266
  • [5] Correlation among Myopic Correction, Axial Length and Aberration after Orthokeratology Lens Treatment in Myopic Patients
    Lee, Dong Hyun
    Lee, Ji Eun
    [J]. JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2016, 57 (07): : 1050 - 1055
  • [6] Long-Term Axial Length Shortening in Myopic Orthokeratology: Incident Probability, Time Course, and Influencing Factors
    Hu, Yin
    Ding, Xiaohu
    Jiang, Jinyun
    Yu, Mengting
    Chen, Linxing
    Zhai, Zhou
    Zhang, Hening
    Fang, Binglan
    Wang, Huarong
    Yu, Shuiming
    He, Mingguang
    Zeng, Junwen
    Zeng, Yangfa
    Yang, Xiao
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2023, 64 (15)
  • [7] Photopic pupil size change in myopic orthokeratology and its influence on axial length elongation
    Zhu, Meng-Jun
    Ding, Li
    Du, Lin-Lin
    Chen, Jun
    He, Xian-Gui
    Li, Shan-Shan
    Zou, Hai-Dong
    [J]. INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2022, 15 (08) : 1322 - 1330
  • [8] Photopic pupil size change in myopic orthokeratology and its influence on axial length elongation
    Meng-Jun Zhu
    Li Ding
    Lin-Lin Du
    Jun Chen
    Xian-Gui He
    Shan-Shan Li
    Hai-Dong Zou
    [J]. International Journal of Ophthalmology, 2022, 15 (08) : 1322 - 1330
  • [9] Validity of Axial Length Measurements for Monitoring Myopic Progression in Orthokeratology
    Cheung, Sin-Wan
    Cho, Pauline
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (03) : 1613 - 1615
  • [10] Central and Peripheral Corneal Power Change in Myopic Orthokeratology and Its Relationship With 2-Year Axial Length Change
    Zhong, Yuanyuan
    Chen, Zhi
    Xue, Feng
    Miao, Huamao
    Zhou, Xingtao
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (08) : 4514 - 4519