Accuracy of 3D fluoro-navigated anterior transpedicular screws in the subaxial cervical spine: an experimental study on human specimens

被引:6
|
作者
Bredow, Jan [1 ,2 ]
Meyer, C. [2 ]
Siedek, F. [3 ]
Neiss, W. F. [4 ]
Loehrer, L. [1 ]
Mueller, L. P. [2 ]
Eysel, P. [2 ]
Stein, G. [2 ]
机构
[1] Schon Klin Dusseldorf SE & Co KG, Ctr Spinal Surg, Schon Klin Dusseldorf, Heerdter Krankenhaus 2, D-40549 Dusseldorf, Germany
[2] Univ Hosp Cologne, Dept Orthopaed & Trauma Surg, Cologne, Germany
[3] Univ Hosp Cologne, Dept Radiol, Cologne, Germany
[4] Univ Cologne, Fac Med, Dept Anat 1, Cologne, Germany
关键词
Anterior transpedicular screws; Navigated screw insertion; Accuracy of screw insertion; Spine surgery; PEDICLE SCREW; POSTERIOR INSTRUMENTATION; CLINICAL ARTICLE; FIXATION; COMPLICATIONS; PLACEMENT; INSERTION; MULTICENTER; CORPECTOMY; SURGERY;
D O I
10.1007/s00586-017-5238-9
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Pedicle screw stabilization, the standard technique in the thoracic and lumbar spine, is increasingly used in the cervical spine. Initial studies on the use of anterior pedicle screws (ATPS) in the cervical spine have been recently published. ATPS use has theoretical advantages over posterior stabilization. We have already established a 3D-fluoroscopy navigation setup in a study of artificial bones. The aim of the current study was to evaluate the positioning quality/accuracy of ATPS introduced to human specimens. 36 cannulated screws (3.5 mm) were implanted anteriorly into the C3-C7 segments of four spines (unfixed, frozen, cadaveric specimens) using a 3D-fluoroscopy navigation system. Placement accuracy was evaluated using a recently published classification on postoperative CT scans. Grade 1 is perfect position with pedicle wall perforation < 1 mm, grade 2 is perforation < 2 mm, etc., and finally grade 5 is cortical perforation of > 4 mm and/or transverse foramen entry. 36 anterior pedicle screws were inserted into four human cervical spine specimens. Of these, seven screws were introduced to C3, five to C4 and eight each to C5, C6, and C7. Classified with the modified G&R, 21 of 36 (58.3%) were grade 1. Ten screws (27.8%) were grade 2. Grade 4 was assessed for two screws and grade 5 for three. Customary "good" positioning, combining grades 1 and 2, was thus found in 86.1%. Five screws (13.9%) did not meet this criterion (grade ae<yen>3). With 86.1% of good positioning (grade 2 or better), a 3D-fluoroscopy navigation of ATPS screws into human c-spine specimens achieved a satisfying results. These are at least comparable to results presented in the literature for posteriorly introduced subaxial pedicle screws.
引用
收藏
页码:2934 / 2940
页数:7
相关论文
共 50 条
  • [1] Accuracy of 3D fluoro-navigated anterior transpedicular screws in the subaxial cervical spine: an experimental study on human specimens
    Jan Bredow
    C. Meyer
    F. Siedek
    W. F. Neiss
    L. Löhrer
    L. P. Müller
    P. Eysel
    G. Stein
    European Spine Journal, 2017, 26 : 2934 - 2940
  • [2] Accuracy of 3D fluoroscopy-navigated anterior transpedicular screw insertion in the cervical spine: an experimental study
    Bredow, Jan
    Meyer, Carolin
    Scheyerer, Max Joseph
    Siedek, Florian
    Mueller, Lars Peter
    Eysel, Peer
    Stein, Gregor
    EUROPEAN SPINE JOURNAL, 2016, 25 (06) : 1683 - 1689
  • [3] Accuracy of 3D fluoroscopy-navigated anterior transpedicular screw insertion in the cervical spine: an experimental study
    Jan Bredow
    Carolin Meyer
    Max Joseph Scheyerer
    Florian Siedek
    Lars Peter Müller
    Peer Eysel
    Gregor Stein
    European Spine Journal, 2016, 25 : 1683 - 1689
  • [4] The accuracy of 3D fluoroscopy-navigated screw insertion in the upper and subaxial cervical spine
    Bredow, J.
    Oppermann, J.
    Kraus, B.
    Schiller, P.
    Schiffer, G.
    Sobottke, R.
    Eysel, P.
    Koy, T.
    EUROPEAN SPINE JOURNAL, 2015, 24 (12) : 2967 - 2976
  • [5] The accuracy of 3D fluoroscopy-navigated screw insertion in the upper and subaxial cervical spine
    J. Bredow
    J. Oppermann
    B. Kraus
    P. Schiller
    G. Schiffer
    R. Sobottke
    P. Eysel
    T. Koy
    European Spine Journal, 2015, 24 : 2967 - 2976
  • [6] Anterior transpedicular screws in conjunction with plate fixation and fusion for the treatment of subaxial cervical spine diseases
    Jie Li
    Liujun Zhao
    Wangmi Liu
    Weihu Ma
    Rongming Xu
    Wei-yu Jiang
    Yongjie Gu
    Liangjie Lu
    Liang Yu
    Feng Qi
    European Spine Journal, 2015, 24 : 1681 - 1690
  • [7] Anterior transpedicular screws in conjunction with plate fixation and fusion for the treatment of subaxial cervical spine diseases
    Li, Jie
    Zhao, Liujun
    Liu, Wangmi
    Ma, Weihu
    Xu, Rongming
    Jiang, Wei-yu
    Gu, Yongjie
    Lu, Liangjie
    Yu, Liang
    Qi, Feng
    EUROPEAN SPINE JOURNAL, 2015, 24 (08) : 1681 - 1690
  • [8] Anterior cervical transpedicular screw fixation system in subaxial cervical spine: A finite element comparative study
    Li, Jie
    Gan, Kaifeng
    Chen, Binhui
    Chen, Yilei
    Hong, Jinjiong
    Bei, Dikai
    Fan, Tengdi
    Zheng, Minzhe
    Zhao, Liujun
    Zhao, Fengdong
    MEDICINE, 2022, 101 (29) : E29316
  • [9] Accuracy of a patient-specific 3D printed drill guide for placement of cervical transpedicular screws
    Hamilton-Bennett, Sinead E.
    Oxley, Bill
    Behr, Sebastien
    VETERINARY SURGERY, 2018, 47 (02) : 236 - 242
  • [10] 3D-Navigated Implantation of Pedicle Screws in the Cervical Spine Experience and Analysis of Complications
    Schiffer, G.
    Goldmann, S.
    Faymonville, C.
    Mueller, L.
    Stein, G.
    ZEITSCHRIFT FUR ORTHOPADIE UND UNFALLCHIRURGIE, 2016, 154 (05): : 483 - 487