Efficacy of cryoballoon ablation in patients with paroxysmal atrial fibrillation without time to pulmonary vein isolation assessment

被引:9
|
作者
Stabile, Giuseppe [1 ]
Tondo, Claudio [2 ]
Curnis, Antonio [3 ]
Lunati, Maurizio [4 ]
Manfrin, Massimiliano [5 ]
Molon, Giulio [6 ]
Sciarra, Luigi [7 ]
Mantica, Massimo [8 ]
Iacopino, Saverio [9 ]
Arena, Giuseppe [10 ]
Landolina, Maurizio [11 ]
Arestia, Alberto [1 ]
Verlato, Roberto [12 ]
机构
[1] Clin Mediterranea, Naples, Italy
[2] Univ Milan, Cardiac Arrhythmia Res Ctr, Ctr Cardiol Monzino, IRCCS, Milan, Italy
[3] Azienda Osped Spedali Civili, Brescia, Italy
[4] Osped ASST GOM Niguarda, Milan, Italy
[5] Osped Civile Bolzano, Bolzano, Italy
[6] Osped Sacro Cuore Don Calabria, Negrar, Italy
[7] Policlin Casilino, Rome, Italy
[8] Ist Clin St Ambrogio, Milan, Italy
[9] Villa Maria Cecilia, Cotignola, RA, Italy
[10] Nuovo Osped Apuane, Massa, Italy
[11] Osped Maggiore Crema, Crema, Italy
[12] ULSS 6 Euganea, Camposampiero, Italy
关键词
Atrial fibrillation; Catheter ablation; Cryoballoon; Pulmonary vein isolation; Mid-term outcome; RADIOFREQUENCY ABLATION; SINGLE; 3-MINUTE; SHORT-TIP; CATHETER; RECORDINGS; STRATEGY; FREEZE; SAFETY;
D O I
10.1016/j.ijcard.2018.07.070
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Real-time visualization of the electrical activity of the pulmonary veins (PV) is not always possible in the setting of atrial fibrillation (AF) cryoballoon ablation. We investigated the relation between the effective documentation of time to PV isolation and the clinical outcome in a cohort of patients with paroxysmal AF who underwent cryoballoon ablation. Methods: One thousand forty two consecutive patients were enrolled. An inner lumen mapping catheter was typically used to visualize real-time electrical activity inside the PVs. Results: Time to PV isolation was documented in all targeted PVs in 391 patients (Group 1), in 651 patients it was not possible to record PV potentials and assess time to PV isolation in at least one PV (Group 2). In Group 1 a longer procedure duration and ablation time were observed, while a longer fluoroscopy time was observed in Group 2. After a mean follow-up of 14 +/- 11 months, 209/1042 (20%) patients had an atrial arrhythmia recurrence (202% in Group 1, 19.9% in Group 2, p = 025). Complications occurred in 54/1042 (5.2%) patients without any difference among the two study groups. Conclusion: In our retrospective analysis, in about two thirds of patients undergoing cryoballoon ablation it was not possible to acutely assess time to PV isolation in all PVs. However, one-year freedom from clinically symptomatic atrial tachyarrhythmia was similar to that of patients in which time to PV isolation was documented in all targeted veins. (C) 2018 Published by Elsevier B.V.
引用
收藏
页码:118 / 122
页数:5
相关论文
共 50 条
  • [1] Cryoballoon ablation for pulmonary vein isolation in patients with paroxysmal atrial fibrillation
    Kuehne, Michael
    Schaer, Beat
    Ammann, Peter
    Suter, Yves
    Osswald, Stefan
    Sticherling, Christian
    [J]. SWISS MEDICAL WEEKLY, 2010, 140 (15-16) : 214 - 221
  • [2] The assessment of the application and the efficacy of pulmonary vein isolation with cryoballoon for non-paroxysmal atrial fibrillation
    Nitta, G.
    Inaba, O.
    Kato, S.
    Kono, T.
    Ikenouchi, T.
    Murata, K.
    Matsuda, J.
    Kanoh, M.
    Inamura, Y.
    Takamiya, T.
    Negi, K.
    Sato, A.
    Yamato, T.
    Matsumura, Y.
    Nitta, J.
    [J]. EUROPEAN HEART JOURNAL, 2019, 40 : 1209 - 1209
  • [3] Efficacy and safety of cryoballoon pulmonary vein isolation for paroxysmal and persistent atrial fibrillation: A comparison with radiofrequency ablation
    Choi, Ji-Hoon
    Park, Seung-Jung
    Park, Kyoung-Min
    Kim, June Soo
    On, Young Keun
    [J]. PLOS ONE, 2022, 17 (07):
  • [4] Efficacy of pulmonary vein isolation by cryoballon ablation in patients with paroxysmal atrial fibrillation
    Klein, Gunnar
    Oswald, Hanno
    Gardiwal, Ajmal
    Luesebrink, Ulrich
    Lissel, Christoph
    Yu, Hong
    Drexler, Helmut
    [J]. HEART RHYTHM, 2008, 5 (06) : 802 - 806
  • [5] SAFETY AND EFFICACY PROFILE OF PULMONARY VEIN ISOLATION USING CRYOBALLOON ABLATION VERSUS LASER BALLOON ABLATION FOR PATIENTS WITH PAROXYSMAL ATRIAL FIBRILLATION
    Magdon, Dorota
    Mounir, Abdulghani
    Ali, Mahmoud
    Erickson, Lynn
    Adefisoye, James
    Kieu, Andy
    Malik, Abdullah
    Ajam, Tarek
    Premjee, Mohammed M.
    Jahangir, Arshad
    Mortada, M. Eyman
    Bhatia, Atul
    Niazi, Imran
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2024, 83 (13) : 68 - 68
  • [6] Reconnection Sites in Redo Ablation after Cryoballoon Pulmonary Vein Isolation in Patients with Paroxysmal Atrial Fibrillation
    Robledo Nolasco, Rogelio
    De Leon-Larios, Gerardo
    Eduardo Bazzini-Carranza, David
    Zavaleta, Elias
    Calixto-Vargas, Omar
    [J]. ARQUIVOS BRASILEIROS DE CARDIOLOGIA, 2021, 117 (01) : 100 - 105
  • [7] The efficacy of inducibility and circumferential ablation with pulmonary vein isolation in patients with paroxysmal atrial fibrillation
    Chang, Shih-Lin
    Tai, Ching-Tai
    Lin, Yenn-Jiang
    Wongcharoen, Wanwarang
    Lo, Li-Wei
    Tuan, Ta-Chuan
    Udyavar, Ameya R.
    Chang, Sheng-Hsiung
    Tsao, Hsuan-Ming
    Hsieh, Ming-Hsiung
    Hu, Yu-Feng
    Chen, Yi-Jen
    Chen, Shih-Ann
    [J]. JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2007, 18 (06) : 607 - 611
  • [8] Efficacy of Cryoballoon Pulmonary Vein Isolation in Patients With Persistent Atrial Fibrillation
    Guhl, Emily
    Siddoway, Donald
    Adelstein, Evan
    Saba, Samir
    Voigt, Andrew
    Jain, Sandeep K.
    [J]. CIRCULATION, 2015, 132
  • [9] Efficacy of Cryoballoon Pulmonary Vein Isolation in Patients With Persistent Atrial Fibrillation
    Guhl, Emily N.
    Siddoway, Donald
    Adelstein, Evan
    Voigt, Andrew
    Saba, Samir
    Jain, Sandeep K.
    [J]. JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2016, 27 (04) : 423 - 427
  • [10] Cryoballoon Pulmonary Vein Isolation for the Treatment of Paroxysmal Atrial Fibrillation.
    Furnkranz, A.
    Chun, J.
    Schmidt, B.
    Ouyang, F.
    Kuck, K. -H.
    [J]. JOURNAL FUR KARDIOLOGIE, 2010, 17 (5-6): : 154 - 156