Comparison of Marginal Fit and Internal Adaptation of Copings Fabricated with Polyetheretherketone and Zirconia - An In vitro Study

被引:5
|
作者
Amalorpavam, V [1 ]
Sreelal, T. [2 ]
Chandramohan, Giri [2 ]
Jithin, G. N. [3 ]
Ponjayanthi [4 ]
Kamalashankar [5 ]
机构
[1] Rajas Dent Coll & Hosp, Dept Prosthodont, Tirunelveli 627105, Tamil Nadu, India
[2] Sree Mookambika Inst Dent Sci, Dept Prosthodont, Kulasekaram, Kanya Kumari, India
[3] Smile Care Multispecial Dent Clin, Trivandrum, Kerala, India
[4] Vivekanadha Dent Coll Women, Dept Prosthodont, Tiruchengode, India
[5] Chettinad Dent Coll, Dept Prosthodont, Chennai, Tamil Nadu, India
来源
关键词
Copings; internal adaptation; marginal fit; polyetheretherketone; zirconia; CERAMIC CROWNS;
D O I
10.4103/jpbs.jpbs_328_21
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Context: Purpose: The aim of this in vitro study was to evaluate and compare the Marginal fit and Internal adaptation of copings fabricated with polyetheretherketone (PEEK) and Zirconia luted with resin cements. Materials and Methods: Maxillary first premolar was prepared to receive all ceramic restoration. It was duplicated using addition silicon impression material for fabricating Cobalt-Chromium metal die, which is used as a master die. Using the master die, 30 heat cure acrylic samples were fabricated for the heat cure acrylic tooth models on which 15 PEEK and 15 zirconia copings were made. Self-adhesive resin cement is used for luting and 30 copings were luted. After 24 h, luted copings were having a disc of thickness 0.01 mm cutting at high speed using a Tooth cutting lathe for all the 30 samples. Field Scanning Electron Microscopic study analysis for evaluating marginal fit and internal adaptation of two groups were observed. The values were then analyzed using one-way ANOVA (post hoc) followed by Dunnet t-test. Results: Among those two groups, PEEK copings group materials showed the lowest mean value of (30.3 +/- 5.1) for marginal gap, (29.1 +/- 5.8) for internal gap whereas the zirconia copings group showed a mean value of (50.26 +/- 16.02) and (32.8 +/- 5.2) respectively. Conclusion: Among these two groups, comparatively less marginal fit and internal adaptation is seen in zirconia copings when compared to the PEEK copings. While the marginal fit and internal adaptation of both PEEK and zirconia copings were in the acceptable clinical range.
引用
收藏
页码:S1199 / S1205
页数:7
相关论文
共 50 条
  • [1] Effect of Die Materials on Marginal and Internal Adaptation of Zirconia Copings: An In Vitro Study
    Al-Mussawi, Raja M.
    Farid, Farzaneh
    Haider, Julfikar
    OPEN DENTISTRY JOURNAL, 2021, 15 : 708 - 716
  • [2] Comparison of marginal and internal adaptation of copings fabricated from three different fabrication techniques: An in vitro study
    Arora, Aman
    Yadav, Avneet
    Upadhyaya, Viram
    Jain, Prachi
    Verma, Mrinalini
    JOURNAL OF INDIAN PROSTHODONTIC SOCIETY, 2018, 18 (02): : 102 - 107
  • [3] Marginal fit of zirconia copings fabricated after conventional impression making and digital scanning: An in vitro study
    Vaz, Ines Margarida Carrilho Baltazar
    Carracho, Jose Fausto Pimentel Coelho Lino
    JOURNAL OF PROSTHETIC DENTISTRY, 2020, 124 (02): : 223.e1 - 223.e6
  • [4] Three-dimensional analysis of marginal and internal fit of copings fabricated with polyetherketoneketone (PEKK) and zirconia
    Bae, So-Yeon
    Park, Jin-Young
    Jeong, Il-Do
    Kim, Hae-Young
    Kim, Ji-Hwan
    Kim, Woong-Chul
    JOURNAL OF PROSTHODONTIC RESEARCH, 2017, 61 (02) : 106 - 112
  • [5] Influence of preparation angle on marginal and internal fit of CAD/CAM-fabricated zirconia crown copings
    Beuer, Florian
    Aggstaller, Hans
    Richter, Juliane
    Edelhoff, Daniel
    Gernet, Wolfgang
    QUINTESSENCE INTERNATIONAL, 2009, 40 (03): : 243 - 250
  • [6] Effect of Preparation Depth Differences on the Marginal Fit of Zirconia Crown Copings: An In Vitro Study
    Azar, Mehdi Sattari
    Lehmann, Karl Martin
    Dietrich, Helmut
    Weibrich, Gernot
    Schmidtmann, Irene
    Scheller, Herbert
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2011, 24 (03) : 264 - 266
  • [7] Comparison of Marginal Fit of Zirconia Copings Produced by Different Systems and Materials
    Gultekin, Pinar
    Sen, Deniz
    Aydin, Murat
    JOURNAL OF ISTANBUL UNIVERSITY FACULTY OF DENTISTRY, 2013, 47 (01) : 28 - 37
  • [8] Evaluation of the Marginal and Internal Fit of Implant-Supported Metal Copings Fabricated with 3 Different Techniques: An In Vitro Study
    Yildirim, Bengisu
    Paken, Gamze
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2019, 28 (03): : 315 - 320
  • [9] In Vitro Evaluation of Marginal Adaptation of Polyether Ether Ketone and Zirconia Copings
    Chouksey, P.
    Yadav, N. S.
    Hazari, P.
    Saxena, V
    Mahajan, H.
    Narwani, S.
    Somkuwar, K.
    Alzahrani, A. H.
    Alqahtani, S. M.
    Robaian, A.
    Alamoudi, Ahmed
    Zidane, B.
    Albar, N.
    Baeshen, H. A.
    Patil, S.
    NIGERIAN JOURNAL OF CLINICAL PRACTICE, 2023, 26 (06) : 701 - 708
  • [10] In vitro evaluation of the internal and marginal misfit of CAD/CAM zirconia copings
    Lins, Leonardo
    Bemfica, Vinicius
    Queiroz, Celso
    Canabarro, Antonio
    JOURNAL OF PROSTHETIC DENTISTRY, 2015, 113 (03): : 205 - 211