Magnetic immunoassays utilizing magnetic markers and a high-TC SQUID

被引:23
|
作者
Enpuku, K [1 ]
Inoue, K
Soejima, K
Yoshinaga, K
Kuma, H
Hamasaki, N
机构
[1] Kyushu Univ, Res Inst Superconductor Sci & Syst, Fukuoka 8128581, Japan
[2] Kyushu Inst Technol, Dept Appl Chem, Kitakyushu, Fukuoka 8048550, Japan
[3] Kyushu Univ, Dept Med Sci, Fukuoka 8128582, Japan
关键词
high-T-C SQUID; immunoassay; magnetic nanoparticle; remanence;
D O I
10.1109/TASC.2005.849991
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Magnetic immunoassays utilizing magnetic markers and a high-T-c SQUID have been performed. We first showed a design of the SQUID for the sensitive detection of the magnetic signal from the marker, where the spatial distribution of the signal field was taken into account. Using the design, we can obtain the relationship between the magnetization of the maker and the signal flux detected with the SQUID. This relationship is important for quantitative evaluation of the immunoassay. Next, we detected biological materials called IgE with a remanence measurement method, where a marker made of Fe3O4 particles with diameter of 25 nm was used. We showed that 2 atto-mol of IgE can be detected, which shows high sensitivity of the present method.
引用
收藏
页码:660 / 663
页数:4
相关论文
共 50 条
  • [1] Liquid phase immunoassays utilizing magnetic markers and SQUID magnetometer
    Kuma, Hiroyuki
    Oyamada, Hiroko
    Tsukamoto, Akira
    Mizoguchi, Takako
    Kandori, Akihiko
    Sugiura, Yoshinori
    Yoshinaga, Kohji
    Enpuku, Keiji
    Hamasaki, Naotaka
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2010, 48 (09) : 1263 - 1269
  • [2] Superconducting magnetic shield for high-Tc squid
    Kantser, V
    Konopko, L
    Panaitov, G
    SENSORS AND ACTUATORS A-PHYSICAL, 1997, 59 (1-3) : 313 - 315
  • [3] High-Tc rf SQUID for magnetic microscopy
    Khvostov, SS
    Timofeev, VP
    Garbuz, AS
    Shnyrkov, VI
    LOW TEMPERATURE PHYSICS, 2003, 29 (02) : 155 - 158
  • [4] High-Tc SQUID system for biological immunoassays
    Enpuku, K
    Hotta, M
    Nakahodo, A
    PHYSICA C-SUPERCONDUCTIVITY AND ITS APPLICATIONS, 2001, 357 : 1462 - 1465
  • [5] High-Tc SQUID gradiometer system for immunoassays
    Oisjoen, F.
    Magnelind, P.
    Kalabukhov, A.
    Winkler, D.
    SUPERCONDUCTOR SCIENCE & TECHNOLOGY, 2008, 21 (03):
  • [6] High Tc SQUID system and magnetic marker for biological immunoassays
    Enpuku, K
    Kuroda, D
    Yang, TQ
    Yoshinaga, K
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2003, 13 (02) : 371 - 376
  • [7] Detection of magnetic nanoparticles with high Tc SQUID and application to biological immunoassays
    Minotani, T
    Gima, T
    Enpuku, K
    ADVANCES IN SUPERCONDUCTIVITY XII, 2000, : 1030 - 1032
  • [8] High-Tc SQUID gradiometer for mobile magnetic anomaly detection
    Clem, TR
    Overway, DJ
    Purpura, JW
    Bono, JT
    Koch, RH
    Rozen, JR
    Keefe, GA
    Willen, S
    Mohling, RA
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2001, 11 (01) : 871 - 875
  • [9] Bio-application of high-Tc SQUID magnetic sensor
    Tanaka, Saburo
    Aspanut, Zarina
    Kurita, Hirofumi
    Toriyabe, Chika
    Hatuskade, Yoshimi
    Katsura, Shinji
    JOURNAL OF MAGNETISM AND MAGNETIC MATERIALS, 2006, 300 (01) : E315 - E319
  • [10] Measuring the absolute magnetic field using high-Tc SQUID
    He, D. F.
    Itozaki, H.
    7TH EUROPEAN CONFERENCE ON APPLIED SUPERCONDUCTIVITY (EUCAS'05), 2006, 43 : 1227 - 1230