The Influence of the Azimuth RCS Pattern of Calibrator on SAR Absolute Calibration

被引:2
|
作者
Du, Shaoyan [1 ,2 ]
Hong, Jun [1 ]
Wang, Yu [1 ]
Xing, Kaichu [1 ,2 ]
Qiu, Tian [1 ,2 ]
Huang, Jianjun [3 ,4 ]
机构
[1] Chinese Acad Sci, Aerosp Informat Res Inst, Natl Key Lab Sci & Technol Microwave Imaging, Beijing 100094, Peoples R China
[2] Univ Chinese Acad Sci, Sch Elect Elect & Commun Engn, Beijing 100049, Peoples R China
[3] Beihang Univ, Sch Elect & Informat Engn, Beijing 100191, Peoples R China
[4] Beijing Inst Remote Sensing Informat, Beijing 100089, Peoples R China
基金
中国国家自然科学基金;
关键词
Azimuth; Synthetic aperture radar; Calibration; Microwave radiometry; Radar polarimetry; Numerical models; Microwave imaging; Absolute radiometric calibration; radar cross section (RCS); synthetic aperture radar (SAR);
D O I
10.1109/LGRS.2021.3120433
中图分类号
P3 [地球物理学]; P59 [地球化学];
学科分类号
0708 ; 070902 ;
摘要
The realization of radiometric calibration relies on the known artificial point targets as the reference, such as corner reflectors. One of the criteria of the calibrator is that the 3 dB-beamwidth of the azimuth radar cross section (RCS) pattern needs to be larger than the synthetic aperture radar (SAR) antenna 3-dB beamwidth to ensure the SAR antenna, which has a narrow azimuth beamwidth, can align to the calibrator while also making the nominal RCS value of the calibrator approximately constant during the radiometric calibration. However, the RCS of the calibrator is actually inconstant within a synthetic aperture period, especially when the SAR antenna beamwidth is wide. The simplified treatment will introduce errors to calibration. In this letter, the azimuth RCS pattern is taken into account. The error caused by the constant RCS is modeled. Based on the error model, an improved criterion of the calibrator is discussed. The experiments use the known SAR system parameters for numerical simulation based on dihedral corner reflectors (DCRs) with different sizes. The results verify the error model and indicate that when the SAR beamwidth is larger than the beamwidth of the calibrator, and the introduced error cannot be ignored. The relationship between the size of the calibrator and the SAR beamwidth is further analyzed through the experiments.
引用
收藏
页数:5
相关论文
共 50 条
  • [1] SAR Image Absolute Radiometric Calibration Based on RCS Modeling of Communication Tower
    Li J.
    Li Y.
    Zhao Q.
    Jiang H.
    Hong Y.
    [J]. Wuhan Daxue Xuebao (Xinxi Kexue Ban)/Geomatics and Information Science of Wuhan University, 2021, 46 (11): : 1746 - 1755
  • [2] REMOTE PROGRAMMABLE TEMPERATURE STABILIZED POLARIMETRIC ACTIVE RADAR CALIBRATOR WITH RCS AGILITY FOR AIRBORNE AND SPACEBORNE SAR CALIBRATION
    Kashanianfard, M.
    Sarabandi, K.
    Nashashibi, A.
    Sarabandi, A.
    Duan, X.
    Chapman, B.
    [J]. IGARSS 2018 - 2018 IEEE INTERNATIONAL GEOSCIENCE AND REMOTE SENSING SYMPOSIUM, 2018, : 9204 - 9207
  • [3] Robust absolute calibration for SAR
    Crisp, David J.
    [J]. 2018 INTERNATIONAL CONFERENCE ON RADAR (RADAR), 2018,
  • [4] Absolute calibration of the Landsat Thematic Mapper using the Internal Calibrator
    Helder, D
    Boncyk, W
    Morfitt, R
    [J]. IGARSS '98 - 1998 INTERNATIONAL GEOSCIENCE AND REMOTE SENSING SYMPOSIUM, PROCEEDINGS VOLS 1-5: SENSING AND MANAGING THE ENVIRONMENT, 1998, : 2716 - 2718
  • [5] ABSOLUTE RADIOMETRIC CALIBRATION OF THE CCRS SAR
    ULANDER, LMH
    HAWKINS, RK
    LIVINGSTONE, CE
    LUKOWSKI, TI
    [J]. IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 1991, 29 (06): : 922 - 933
  • [6] Improved channel error calibration method for the azimuth multichannel SAR
    Zuo S.
    Sun G.
    Xing M.
    [J]. 1600, Science Press (44): : 13 - 18
  • [7] AZIMUTH BEAM PATTERN SYNTHESIS FOR AIRBORNE SAR SYSTEM OPTIMIZATION
    Lim, S. H.
    Han, J. H.
    Kim, S. Y.
    Myung, N. H.
    [J]. PROGRESS IN ELECTROMAGNETICS RESEARCH-PIER, 2010, 106 : 295 - 309
  • [8] Improved Channel Error Calibration Algorithm for Azimuth Multichannel SAR Systems
    Guo, Xiaojiang
    Gao, Yesheng
    Wang, Kaizhi
    Liu, Xingzhao
    [J]. IEEE GEOSCIENCE AND REMOTE SENSING LETTERS, 2016, 13 (07) : 1022 - 1026
  • [9] COSMO-SkyMed Active Calibrator: a sophisticated tool for SAR image calibration
    Falzini, S.
    Speziale, V.
    De Viti, E.
    [J]. IGARSS: 2007 IEEE INTERNATIONAL GEOSCIENCE AND REMOTE SENSING SYMPOSIUM, VOLS 1-12: SENSING AND UNDERSTANDING OUR PLANET, 2007, : 1577 - 1580
  • [10] Phase Mismatch Calibration of the Multichannel SAR Based on Azimuth Cross Correlation
    Feng, Jin
    Gao, Canguan
    Zhang, Yi
    Wang, Robert
    [J]. IEEE GEOSCIENCE AND REMOTE SENSING LETTERS, 2013, 10 (04) : 903 - 907