A Case of False-positive Amphetamine Results on Urine Toxicology Testing Secondary to Imatinib

被引:4
|
作者
Meyers, Sarah [1 ]
Wachman, Elisha M. [1 ,2 ]
机构
[1] Boston Univ, Sch Med, Boston, MA 02118 USA
[2] Boston Med Ctr, Dept Pediat, Boston, MA 02119 USA
关键词
amphetamine; chronic myelocytic leukemia; false-positive; imatinib; postpartum drug testing; urine drug screen; urine toxicology screening; CLINICAL PHARMACOKINETICS; IMMUNOASSAYS;
D O I
10.1097/ADM.0000000000000766
中图分类号
R194 [卫生标准、卫生检查、医药管理];
学科分类号
摘要
In this case report, we describe a case of imatinib leading to a false-positive amphetamine result on urine drug testing. A 21-year-old female with chronic myelocytic leukemia and in recovery from opioid use disorder reinitiated imatinib maintenance therapy in her third trimester, after previous discontinuation at the beginning of pregnancy. Subsequently, she had multiple presumptive immunoassay-based urine drug tests that resulted positive for amphetamines. The infant's meconium testing was negative for amphetamines, as was maternal definitive testing using urine gas chromatography-mass spectrometry. She had no history of stimulant use and denied any substance use during her pregnancy. Imatinib and/or its metabolites may be responsible for cross-reactivity with urine drug immunoassays leading to a false-positive result for amphetamine.