The beam emission spectroscopy diagnostic on the DIII-D tokamak

被引:195
|
作者
McKee, G [1 ]
Ashley, R
Durst, R
Fonck, R
Jakubowski, M
Tritz, K
Burrell, K
Greenfield, C
Robinson, J
机构
[1] Univ Wisconsin, Madison, WI 53706 USA
[2] Gen Atom Co, San Diego, CA 92186 USA
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 1999年 / 70卷 / 01期
关键词
D O I
10.1063/1.1149416
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A beam emission spectroscopy system has been installed on DIII-D to provide localized density fluctuation measurements for long-wavelength turbulent modes with k less than or equal to 3 cm(-1) which are typically associated with anomalous radial transport. High signal-to-noise fluctuations measurements are accomplished through use of high speed electronics to maintain a frequency response of over 500 KHz and cryogenically cooled amplifiers and detectors to reduce electronic noise. The optics and neutral beam-sightline geometry have been optimized to allow for spatial resolution of Delta r less than or equal to 1 cm. In addition, a half-scale two-dimensional (2D) fiber array to measure the 2D turbulent density field, necessary to measure the full S(k(r),k(theta)) wavenumber spectra, has been implemented and initial results obtained. (C) 1999 American Institute of Physics. [S0034-6748(99)65801-4].
引用
收藏
页码:913 / 916
页数:4
相关论文
共 50 条
  • [1] The beam emission spectroscopy diagnostic on the DIII-D tokamak (vol 70, pg 913, 1999)
    McKee, G
    Ashley, R
    Durst, R
    Fonck, R
    Jakubowski, M
    Tritz, K
    Burrell, K
    Greenfield, C
    Robinson, J
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1999, 70 (04): : 2179 - 2179
  • [2] Spatial transfer function for the beam emission spectroscopy diagnostic on DIII-D
    Shafer, M. W.
    Fonck, R. J.
    McKee, G. R.
    Schlossberg, D. J.
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2006, 77 (10):
  • [3] Upgrades to the ion cyclotron emission diagnostic on the DIII-D tokamak
    DeGrandchamp, G. H.
    Thome, K. E.
    Heidbrink, W. W.
    Holmes, I.
    Pinsker, R. I.
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2021, 92 (03):
  • [4] Magnetic diagnostic system of the DIII-D tokamak
    Strait, EJ
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2006, 77 (02):
  • [5] DEVELOPMENT OF LITHIUM BEAM EMISSION-SPECTROSCOPY AS AN EDGE FLUCTUATION DIAGNOSTIC FOR DIII-D (INVITED)
    THOMAS, DM
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1995, 66 (01): : 806 - 811
  • [6] Central ion cyclotron emission in the DIII-D tokamak
    Thome, K. E.
    Pace, D. C.
    Pinsker, R., I
    Van Zeeland, M. A.
    Heidbrink, W. W.
    Austin, M. E.
    [J]. NUCLEAR FUSION, 2019, 59 (08)
  • [7] RESULTS OF COUNTERNEUTRAL BEAM INJECTION ON THE DIII-D TOKAMAK
    SCHISSEL, DP
    ALLEN, SL
    BURRELL, KH
    DEBOO, JC
    GROEBNER, RJ
    KELLMAN, AG
    OHYABU, N
    PETERSEN, PI
    SAGER, GT
    SNIDER, RT
    WOOD, RD
    [J]. PHYSICS OF FLUIDS B-PLASMA PHYSICS, 1989, 1 (09): : 1843 - 1849
  • [8] VERTICAL-VIEWING ELECTRON-CYCLOTRON EMISSION DIAGNOSTIC FOR THE DIII-D TOKAMAK
    JAMES, R
    JANZ, S
    ELLIS, R
    BOYD, D
    LOHR, J
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1988, 59 (08): : 1611 - 1613
  • [9] CARBONIZATION OF THE DIII-D TOKAMAK
    JACKSON, GL
    WINTER, J
    LIPPMANN, S
    PETRIE, TW
    DEBOO, JC
    SCHISSEL, DP
    TAYLOR, TS
    [J]. JOURNAL OF NUCLEAR MATERIALS, 1990, 176 : 311 - 318
  • [10] CARBONIZATION OF THE DIII-D TOKAMAK
    JACKSON, GL
    WINTER, J
    LIPPMANN, S
    PETRIE, TW
    DEBOO, JC
    SCHISSEL, DP
    TAYLOR, TS
    [J]. JOURNAL OF NUCLEAR MATERIALS, 1991, 185 (01) : 139 - 146