Adaptive brachytherapy of cervical cancer, comparison of conventional point A and CT based individual treatment planning

被引:14
|
作者
Wanderas, Anne D. [1 ]
Sundset, Marit [2 ]
Langdal, Ingrid [1 ]
Danielsen, Signe [1 ]
Frykholm, Gunilla [1 ]
Marthinsen, Anne B. L. [1 ]
机构
[1] St Olavs Hosp, Dept Oncol, N-7006 Trondheim, Norway
[2] St Olavs Hosp, Dept Gynaecol Oncol, N-7006 Trondheim, Norway
关键词
DOSE-RATE BRACHYTHERAPY; INTRACAVITARY BRACHYTHERAPY; VOLUME PARAMETERS; COMPUTED-TOMOGRAPHY; RECOMMENDATIONS; OPTIMIZATION; APPLICATOR; CARCINOMA; ORGANS; TERMS;
D O I
10.3109/0284186X.2011.626446
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background. Locally advanced cervical cancer is commonly treated with external radiation therapy combined with local brachytherapy. The brachytherapy is traditionally given based on standard dose planning with prescription of dose to point A. Dosimetric aspects when changing from former standard treatment to individualized treatment plans based on computed tomography (CT) images are here investigated. Material and methods. Brachytherapy data from 19 patients with a total of 72 individual treatment fractions were retrospectively reviewed. Standard library plans were analyzed with respect to doses to organs at risk (OARs), and the result was compared to corresponding delivered individualized plans. The theoretical potential of further optimization based on prescription to target volumes was investigated. The treatments were performed with a Fletcher applicator. Results. For standard treatment planning, the tolerance dose limits were exceeded in the bladder, rectum and sigmoid in 26%, 4% and 15% of the plans, respectively. This was observed most often for the smallest target volumes. The individualized planning of the delivered treatment gave the possibility of controlling the dose to critical organs to below certain limits. The dose was still prescribed to point A. An increase in target dose coverage was achieved when additional individual optimization was performed, while still keeping the dose to the OARs below predefined limits. Relatively low average target coverage, especially for the largest volumes was however seen. Conclusion. The individualized delivered treatment plans ensured that doses to OARs were within acceptable limits. This was not the case in 42% of the corresponding standard plans. Further optimized treatment plans were found to give an overall better dose coverage. In lack of MR capacity, it may be favorable to use CT for planning due to possible protection of OARs. The CT based target volumes were, however, not equivalent to the volumes described in magnetic resonance imaging (MRI) based recommendations. Prescription and assessment of dose, when introducing such target volumes, should be evaluated and preferably compared to well known treatment regimens.
引用
收藏
页码:345 / 354
页数:10
相关论文
共 50 条
  • [1] CONVENTIONAL POINT A AND CT BASED INDIVIDUAL TREATMENT PLANNING FOR BRACHYTHERAPY OF CERVICAL CANCER
    Wanderas, A.
    Sundset, M.
    Langdal, I.
    Danielsen, S.
    Marthinsen, A. B.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S298 - S298
  • [2] Adaptive brachytherapy treatment planning for cervical cancer
    Lin, LL
    Mutic, S
    Low, DA
    LaForest, R
    Vicic, M
    Zoberi, I
    Miller, TR
    Grigsby, PW
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 63 (02): : S213 - S214
  • [3] Comparison of conventional and CT-based planning for intracavitary brachytherapy for cervical cancer: target volume coverage and organs at risk doses
    Cem Onal
    Gungor Arslan
    Erkan Topkan
    Berrin Pehlivan
    Melek Yavuz
    Ezgi Oymak
    Aydin Yavuz
    [J]. Journal of Experimental & Clinical Cancer Research, 28
  • [4] Comparison of conventional and CT-based planning for intracavitary brachytherapy for cervical cancer for target volume coverage and organs at risk doses
    Onal, C.
    Arslan, G.
    Topkan, E.
    Yavuz, M.
    Oymak, E.
    Yavuz, A.
    [J]. EJC SUPPLEMENTS, 2009, 7 (02): : 462 - 462
  • [5] Comparison of conventional and CT-based planning for intracavitary brachytherapy for cervical cancer: target volume coverage and organs at risk doses
    Onal, Cem
    Arslan, Gungor
    Topkan, Erkan
    Pehlivan, Berrin
    Yavuz, Melek
    Oymak, Ezgi
    Yavuz, Aydin
    [J]. JOURNAL OF EXPERIMENTAL & CLINICAL CANCER RESEARCH, 2009, 28
  • [6] The use of CT image based treatment planning in cervical brachytherapy
    Yuen, J.
    Davidson, M. T. M.
    D'Souza, D. P.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 69 (03): : S390 - S391
  • [7] Adaptive MRI Image Guided HDR Brachytherapy Treatment Planning for Cervical Cancer
    Apicelli, A. J.
    Dyk, P.
    Sun, B.
    Bertelsman, C.
    Kavanaugh, J.
    DeWees, T.
    Garcia-Ramirez, J.
    Richardson, S.
    Schwarz, J. K.
    Grigsby, P. W.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 84 (03): : S437 - S438
  • [8] Adaptive brachytherapy treatment planning for cervical cancer using FDG-PET
    Lin, Lilie L.
    Mutic, Sasa
    Low, Daniel A.
    LaForest, Richard
    Vicic, Milos
    Zoberi, Imran
    Miller, Tom R.
    Grigsby, Perry W.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 67 (01): : 91 - 96
  • [9] PET/CT Guided Brachytherapy Planning for Cervical Cancer
    Nam, H.
    Huh, S.
    Ju, S.
    Choi, J.
    Kim, B.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (03): : S421 - S421
  • [10] An overview on MRI-based treatment planning for brachytherapy of cervical cancer
    Kirisits, C
    [J]. RADIOTHERAPY AND ONCOLOGY, 2005, 76 : S4 - S5