ATOMS (Adjustable Transobturator Male System) Is an Effective and Safe Second-Line Treatment Option for Recurrent Urinary Incontinence after Implantation of an AdVance/AdVance XP Fixed Male Sling? A Multicenter Cohort Analysis

被引:5
|
作者
Queissert, Fabian [1 ]
Rourke, Keith [2 ]
Schoenburg, Sandra [3 ]
Giammo, Alessandro [4 ]
Gonsior, Andreas [5 ]
Gonzalez-Enguita, Carmen [6 ]
Romero, Antonio [7 ]
Schrader, Andres J. [1 ]
Cruz, Francisco [8 ,9 ]
Martins, Francisco E. [10 ]
Dorado, Juan F. [11 ]
Angulo, Javier C. [12 ]
机构
[1] Univ Munster, Dept Urol & Pediat Urol, Schlosspl 2, D-48149 Munster, Germany
[2] Alberta Univ, Dept Urol, 116 St & 85 Ave, Edmonton, AB T6G 2R3, Canada
[3] Martin Luther Univ Halle Wittenberg, Dept Urol & Kidney Transplantat, Univ 10, D-06108 Halle, Saale, Germany
[4] AOU Citta Salute Sci Torino, Spinal Cord Unit, Dept Neurourol, CTO, Via Gianfranco Zuretti 29, I-10126 Turin, Italy
[5] Univ Leipzig, Klin & Pol Urol, Augustuspl 10, D-04109 Leipzig, Germany
[6] Hosp Univ Fdn Jimenez Diaz, Dept Urol, Av Reyes Catolicos 2, Madrid 28040, Spain
[7] Hosp Univ Morales Meseguer, Dept Urol, Av Marques Velez S-N, Murcia 30008, Spain
[8] Ctr Hosp Sao Joao, Fac Med Porto, Alameda Prof Hernani Monteiro, P-4200319 Porto, Portugal
[9] I3S Inst, Alameda Prof Hernani Monteiro, P-4200319 Porto, Portugal
[10] Univ Lisboa Norte, Ctr Hosp, Hosp Santa Maria, Av Prof Egas Moniz MB, P-1649028 Lisbon, Portugal
[11] PeRTICA Stat Solut, Av Leonardo Da Vinci 8,OF217, Madrid 28906, Spain
[12] Univ Europea Madrid, Fac BioMed Sci, Clin Dept, Carretera Toledo,Km 12-500, Madrid 28905, Spain
关键词
adjustable transobturator male system; stress urinary incontinence; artificial urinary sphincter; fixed male sling; sling failure; SPHINCTER; FAILURE;
D O I
10.3390/jcm11010081
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
(1) Background: This study examined outcomes of second-line ATOMS implantation after failure of the fixed male sling (FMS) AdVance/AdVance XP. (2) Methods: A retrospective multicenter cohort analysis was carried out in men implanted with an ATOMS between 2011 and 2020 after failure of an AdVance/AdVance XP. Success was assessed on the basis of objective (dryness, 0-1 pad/24 h or >20 g/24 h pad test) and subjective results (PGI-I). We performed the Wilcoxon rank sum test, Fisher's exact test, logistic regression, and multivariate analysis. (3) Results: The study included 88 patients from 9 centers with a mean age of 71.3 years. No Clavien-Dindo > II complications occurred within the first 3 months after ATOMS implantation. A total of 10 cases (9%) required revision in the ensuing clinical course. After a mean follow-up of 42.5 months, 76.1% achieved social continence, and 56.8% used no pads at all. Mean urine leakage/24 h dropped from 422 g (3.9 pads) to 38 g (0.69 pads) and the mean ICIQ-SF decreased from 16.25 to 5.3 (p < 0.0001). PROMs (patient-reported outcome measures) showed improvement in 98.9% of cases, and 63.6% gave a "very much better" PGI-I rating. Multivariate analysis identified a lower probability of achieving maximum satisfaction for the following factors: the AdVance XP as first-line therapy (OR 0.35), a lower ICIQ-SF question 1 (OR 0.26), status post-irradiation (OR 0.14), and more severe pain prior to ATOMS implantation (OR 0.51). (4) Conclusions: Implantation of an ATOMS is an effective and safe second-line treatment option for recurrent urinary incontinence after implantation of an AdVance/AdVance XP sling. High patient satisfaction was demonstrated in a long-term follow-up.
引用
收藏
页数:11
相关论文
共 17 条
  • [1] The advance male sling system: A new treatment option to improve male stress urinary incontinence significantly
    Amend, B.
    Horstmann, M.
    Gakis, G.
    Renninger, M.
    Sturm, W.
    Stenzl, A.
    Sievert, K. D.
    [J]. EUROPEAN UROLOGY SUPPLEMENTS, 2008, 7 (03) : 88 - 88
  • [2] Treatment of Recurrent Urinary Incontinence After Artificial Urinary Sphincter Placement Using the AdVance Male Sling
    Christine, Brian
    Knoll, L. Dean
    [J]. UROLOGY, 2010, 76 (06) : 1321 - 1324
  • [3] Extended follow-up of the AdVance XP male sling in the treatment of male urinary stress incontinence after 48 months: Results of a prospective and multicenter study
    Grabbert, Markus
    Mumm, Jan-Niclas
    Klehr, Benedikt
    Kretschmer, Alexander
    Gebhartl, Peter
    Gozzi, Christian
    Homberg, Roland
    May, Florian
    Rehder, Peter
    Stief, Christian G.
    Bauer, Ricarda M.
    [J]. NEUROUROLOGY AND URODYNAMICS, 2019, 38 (07) : 1973 - 1978
  • [4] Treatment of Recurrent Urinary Incontinence After Artificial Urinary Sphincter Placement Using the AdVance Male Sling Editorial Comment
    Morey, Allen F.
    [J]. JOURNAL OF UROLOGY, 2011, 186 (02): : 586 - 586
  • [5] Treatment of Recurrent Urinary Incontinence After Artificial Urinary Sphincter Placement Using the AdVance Male Sling EDITORIAL COMMENT
    Voelzke, Bryan
    [J]. UROLOGY, 2010, 76 (06) : 1324 - 1325
  • [6] Effectiveness and Complications of the AMS AdVance™ Male Sling System for the Treatment of Stress Urinary Incontinence: A Prospective Multicenter Study
    Ye, Haixia
    Haab, Francois
    de Bidder, Dirk
    Chauveau, Philippe
    Becker, Armin
    Arano, Pedro
    Haillot, Olivier
    Fassi-Fehri, Hakim
    [J]. UROLOGY, 2018, 120 : 197 - 204
  • [7] Single institution experience with the transobturator sling suspension system AdVance® in the treatment of male urinary incontinence: mid-term results
    Berger, Andreas P.
    Strasak, Alexander
    Seitz, Christian
    Rein, Patrick
    Hobisch, Alfred
    [J]. INTERNATIONAL BRAZ J UROL, 2011, 37 (04): : 488 - 494
  • [8] Treatment of stress urinary incontinence after prostatectomy with the adjustable transobturator male system (ATOMS®) with preattached scrotal port
    Esquinas, C.
    Arance, I.
    Pamplona, J.
    Moraga, A.
    Dorado, J. F.
    Angulo, J. C.
    [J]. ACTAS UROLOGICAS ESPANOLAS, 2018, 42 (07): : 473 - 482
  • [9] ADJUSTABLE TRANSOBTURATOR MALE SYSTEM (ATOMS®) - A NOVEL TREATMENT OPTION IN MEN WITH STRESS URINARY INCONTINENCE: THE FIRST EXPERIENCE IN THE UNITED KINGDOM
    Yang, Bob
    Jelley, Clare
    Foley, Steve
    [J]. JOURNAL OF UROLOGY, 2019, 201 (04): : E662 - E662
  • [10] Outcomes with the Adjustable Transobturator Male System (ATOMS) for the Treatment of Male Stress Urinary Incontinence After Prostate Surgery and the Impact of Previous Radiotherapy
    Roth, Ingunn
    Juliebo-Jones, Patrick
    Moen, Christian Arvei
    Beisland, Christian
    Hjelle, Karin M.
    [J]. EUROPEAN UROLOGY OPEN SCIENCE, 2024, 62 : 68 - 73