Combination of ultrasound and acousto-optical imaging using a pulsed-ultrasound scanner.

被引:0
|
作者
Bossy, E [1 ]
Sui, L [1 ]
Murray, TW [1 ]
Roy, RA [1 ]
机构
[1] Boston Univ, Dept Aerosp & Mech Engn, Boston, MA 02215 USA
关键词
acousto-optical imaging; photorefractive crystal; pulsed ultrasound; diffusive media;
D O I
10.1117/12.589444
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The acousto-optical sensing (AOS) of a turbid medium is based on the interaction of multiply-scattered coherent laser light with an ultrasonic field. A phase-modulated photon field emanates from the interaction region and carries with it information about the acousto-optical properties of the media. Using a novel technique based on a photorefiractive crystal interferometer, it is possible to detect the ultrasound-modulated optical signals generated by short ultrasound pulses. As opposed to continuous-wave (CW) ultrasound, pulsed ultrasound directly provides resolution along the ultrasonic propagation axis. In this work, a commercial ultrasound scanner (Analogic AN2300) was used in pulse mode (5 MHz central frequency) to generate both conventional ultrasound and AO images. Gel-based highly diffusive ( mu(s)'=10 cm(-1)) tissue-mimicking phantoms were fabricated, with embedded targets possessing acoustical and/or optical contrast. AO images of 26-mm thick phantoms were generated from optical signals averaged in the time-domain, without further signal processing, and were superimposed on the top of the ultrasound images. Good quality AO images of optical absorbers, intrinsically co-registered with the ultrasound images, were obtained within minutes. The axial resolution of the AO images was given by the spatial length of the ultrasound pulse, typically on the order of one turn in the MHz range. These results show that AO signals can be excited in pulse mode using a commercial scanner, and combined to conventional ultrasound images to provide more information related to the optical properties of the medium.
引用
收藏
页码:145 / 153
页数:9
相关论文
共 50 条
  • [1] Fusion of conventional ultrasound imaging and acousto-optic sensing by use of a standard pulsed-ultrasound scanner
    Bossy, E
    Sui, L
    Murray, TW
    Roy, RA
    OPTICS LETTERS, 2005, 30 (07) : 744 - 746
  • [2] Acousto-optical coherence tomography using random phase jumps on ultrasound and light
    Lesaffre, M.
    Farahi, S.
    Gross, M.
    Delaye, P.
    Boccara, A. C.
    Ramaz, F.
    OPTICS EXPRESS, 2009, 17 (20): : 18211 - 18218
  • [3] HARDWARE DESIGN OF AN ULTRASOUND CT SCANNER.
    Dick, Donald E.
    Bay, H.Paul
    Carson, Paul L.
    Biomedical Sciences Instrumentation, 1977, 13 : 31 - 35
  • [4] NDT BY ACOUSTO-OPTICAL IMAGING
    APRAHAMI.R
    BHUTA, PG
    MATERIALS EVALUATION, 1970, 28 (09) : A34 - &
  • [5] NDT BY ACOUSTO-OPTICAL IMAGING
    APRAHAMIAN, R
    BHUTA, PG
    MATERIALS EVALUATION, 1971, 29 (05) : 112 - +
  • [6] Ultrasound-mediated biophotonic imaging: A review of acousto-optical tomography and photo-acoustic tomography
    Wang, LHV
    DISEASE MARKERS, 2003, 19 (2-3) : 123 - 138
  • [7] Theoretical study of acousto-optical coherence tomography using random phase jumps on ultrasound and light
    Lesaffre, M.
    Farahi, S.
    Boccara, A. C.
    Ramaz, F.
    Gross, M.
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2011, 28 (07) : 1436 - 1444
  • [8] Acousto-optical tomography by coaxial detection with frequency-swept ultrasound modulation
    Yong, Y
    Xing, D
    Ueda, K
    BIOMEDICAL OPTOACOUSTICS III, 2002, 4618 : 1 - 6
  • [9] Acousto-optical imaging using a powerful long pulse laser
    Rousseau, Guy
    Blouin, Alain
    Monchalin, Jean-Pierre
    PHOTONICS NORTH 2008, 2008, 7099
  • [10] Acousto-optical TV projection systems with pulsed lasers
    Gulyaev, YV
    Kazaryan, MA
    Mokrushin, YM
    Prokhorov, AM
    Shakin, OV
    LASER PHYSICS, 2002, 12 (11) : 1368 - 1380