Dynamic 11C-Choline PET/CT for the primary diagnosis of prostate cancer

被引:0
|
作者
Golan, Shay [1 ]
Nidam, Meital [2 ]
Bernstine, Hanna [2 ]
Baniel, Jack [1 ]
Groshar, David [2 ]
机构
[1] Sackler Fac Med, Beilinson Hosp, Inst Urol, Rabin Med Ctr, Petah Tiqwa, Israel
[2] Sackler Fac Med, Beilinson Hosp, Dept Nucl Med, Rabin Med Ctr, Petah Tiqwa, Israel
来源
INTERNATIONAL BRAZ J UROL | 2018年 / 44卷 / 05期
关键词
Positron-Emission Tomography; Tomography; Prostatic Neoplasms; X-Ray Computed; LOCALIZATION; THERAPY; TRENDS;
D O I
10.1590/S1677-5538.IBJU.2018.0035
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Objectives: To test the ability of dynamic C-11-PET/CT to discriminate cancerous tissue from background tissue in patients with localized prostate cancer. Materials and Methods: Twenty-four consecutive patients with prostate cancer were prospectively evaluated with dynamic C-11-choline PET/CT prior to radical prostatectomy. The PET/CT scan was divided into 18 sequences of 5 seconds each, followed by 9 sequences of 60 seconds each. Whole-mount sections of harvested prostates served as reference standards. Volumes of interest were positioned on the dynamic PET/CT images and the following quantitative variables were calculated: perfusion coefficient (K1), washout constant (K2), area under the curve (AUC) at 175 and 630 seconds, and average and maximum standardized uptake values (SUVavg, and SUVmax). Wilcoxon signed-ranks test was used to compare benign and cancerous areas of the prostate. Results: Areas of cancerous tissue were characterized by higher SUVavg and SUVmax than areas of benign tissue (3.67 +/- 2.7 vs. 2.08 +/- 1.3 and 5.91 +/- 4.4 vs. 3.71 +/- 3.7, respectively, P < 0.001), in addition to a higher K1 (0.95 +/- 0.58 vs. 0.43 +/- 0.24, P < 0.001) and greater cumulative tracer uptake, represented by the AUC at 175 and 630 seconds (P <0.001). No associations were found between dynamic parameters and preoperative prostate specific antigen level or Gleason score. Conclusions: In this pilot study, C-11-choline PET/CT demonstrated increased tracer uptake with higher values of static and dynamic parameters in areas of prostate cancer compared to areas of benign tissue. Larger studies are warranted to validate these results and examine the potential applicability of C-11-choline dynamic PET/CT for the diagnosis of prostate cancer.
引用
收藏
页码:900 / 905
页数:6
相关论文
共 50 条
  • [1] Performance diagnosis of 11c-choline pet/ct in prostate cancer
    Samper Ots, P. M.
    Luis Cardo, A.
    Cabeza Rodriguez, M. A.
    Vallejo Ocana, C.
    Glaria Enriquez, L. A.
    Couselo Paniagua, M. L.
    Olivera Vegas, J.
    RADIOTHERAPY AND ONCOLOGY, 2017, 123 : S709 - S709
  • [2] 11C-Choline PET/CT in the primary diagnosis of prostate cancer: impact on treatment planning
    Garcia, J. R.
    Jorcano, S.
    Soler, M.
    Linero, D.
    Moragas, M.
    Riera, E.
    Miralbell, R.
    Lomena, F.
    QUARTERLY JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2015, 59 (03): : 342 - 350
  • [3] 11C-Choline PET-CT and multiparametric NMR in the diagnosis of primary prostate cancer
    Hernandez, Miguel
    Quiceno, Hernan
    Rodriguez-Fraile, Macarena
    Solorzano, Jose
    Tienza, Antonio
    Vigil, Carmen
    Ribelles, Maria
    Benito, Alberto
    Pascual, Ignacio
    Richter, Jose
    JOURNAL OF NUCLEAR MEDICINE, 2014, 55
  • [4] Evaluation of 11C-choline PET/CT in the diagnosis and staging of prostate cancer
    Xin, L.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2006, 33 : S208 - S208
  • [5] 11C-Choline PET/CT in the diagnosis of primary prostate cancer. Impact on treatment planning
    Riera, E.
    Garcia, J. R.
    Jorcano, S.
    Soler, M.
    Valls, E.
    Moragas, M.
    Miralbell, R.
    Lomena, F.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2012, 39 : S462 - S462
  • [6] Imaging prostate cancer with 11C-choline PET/CT
    Reske, Sven N.
    Blumstein, Norbert M.
    Neumaier, Bernd
    Gottfried, Hans-Werner
    Finsterbusch, Frank
    Kocot, Darius
    Moeller, Peter
    Glatting, Gerhard
    Perner, Sven
    JOURNAL OF NUCLEAR MEDICINE, 2006, 47 (08) : 1249 - 1254
  • [7] 11C-Choline PET/CT in Recurrent Prostate Cancer
    不详
    JOURNAL OF NUCLEAR MEDICINE, 2013, 54 (01) : 24N - 24N
  • [8] Effectiveness of 11C-choline PET/CT in prostate cancer surveillance
    Martinez-Rodriguez, I.
    de Arcocha-Torres, M.
    Gomez de la Fuente, F. J.
    Jimenez-Bonilla, J.
    Sanchez-Salmoen, A.
    Martinez-Amador, N.
    Mendi-Barcina, V.
    Andres-Pacheco, J.
    Gutierrez-Gonzalez, A.
    Pombo-Lopez, M.
    Bota-Bota, A.
    Rodil-Gallego, M.
    Garcia-Ruiz, A.
    Quirce, R.
    REVISTA ESPANOLA DE MEDICINA NUCLEAR E IMAGEN MOLECULAR, 2023, 42 (02): : 93 - 99
  • [9] Diagnostic Performance of 11C-choline PET/CT and FDG PET/CT in Prostate Cancer
    Kitajima, Kazuhiro
    Yamamoto, Shingo
    Odawara, Soichi
    Kobayashi, Kaoru
    Fujiwara, Masayuki
    Kamikonya, Norihiko
    Fukushima, Kazuhito
    Nakanishi, Yukako
    Hashimoto, Takahiko
    Yamada, Yusuke
    Suzuki, Toru
    Kanematsu, Akihiro
    Nojima, Michio
    Yamakado, Koichiro
    ACTA MEDICA OKAYAMA, 2018, 72 (03) : 289 - 296
  • [10] Value of 11C-choline PET and PET/CT in patients with suspected prostate cancer
    Seitz, M
    Gratzke, C
    Schlenker, B
    Reich, O
    Stief, CG
    Scher, B
    JOURNAL OF UROLOGY, 2006, 175 (04): : 483 - 484