Analysis of the influence of electromagnetic interference of transmission lines on the data quality and positioning accuracy of Beidou deformation monitoring

被引:0
|
作者
Mao, Xiaopo [1 ]
Feng, Zhiqiang [1 ]
Deng, Xiaoguo [2 ]
Yu, Zhijun [3 ]
He, Dongsheng [2 ]
机构
[1] Elect Power Res Inst, State Grid Hubei Elect Power Co Ltd, Wuhan 430077, Hubei, Peoples R China
[2] State Grid Zhuzhou Power Supply Co, Zhuzhou 412000, Hunan, Peoples R China
[3] State Grid Enshi Elect Power Supply Co, Enshi 445000, Hubei, Peoples R China
关键词
GPS;
D O I
10.1063/5.0098038
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
In this paper, aiming at the application of geological disaster monitoring of transmission lines, by analyzing the data quality and positioning accuracy of Beidou original observation data, the influence of the electromagnetic environment of transmission lines on Beidou satellite monitoring data is obtained. According to the Beidou monitoring data of 500 kV transmission line for 23 days, the analysis results show that: in the case of strong electromagnetic interference/no electromagnetic interference, the difference of data integrity is less than 1%, the difference of multipath effect is less than 0.1 m, the difference of signal-to-noise ratio is less than 0.3 dB Hz, and the difference of cycle hop ratio is less than 150. The relative difference in positioning accuracy is less than 5%. In general, the electromagnetic environment of transmission lines has no significant impact on the data quality and positioning accuracy of Beidou deformation monitoring. (c) 2022 Author(s).
引用
收藏
页数:9
相关论文
共 19 条
  • [1] Data quality assessment and the positioning performance analysis of BeiDou in Hong Kong
    Xu, Y.
    Ji, S.
    SURVEY REVIEW, 2015, 47 (345) : 446 - 457
  • [2] Analysis on the Influence of Transmission Lines span on Passive Interference in Shortwave
    Lu Ying
    Zhao Zhibin
    Zhang Jian Gong
    Gan Zheyuan
    2018 3RD INTERNATIONAL CONFERENCE ON POWER AND RENEWABLE ENERGY (ICPRE), 2018, 64
  • [3] Accuracy analysis of continuous deformation monitoring using BeiDou Navigation Satellite System at middle and high latitudes in China
    Jiang, Weiping
    Xi, Ruijie
    Chen, Hua
    Xiao, Yugang
    ADVANCES IN SPACE RESEARCH, 2017, 59 (03) : 843 - 857
  • [4] Analysis of the influence of surface deformation on the stability of overhead transmission lines and countermeasures
    Meng, Xiaokai
    Xu, Siqing
    Hu, Fan
    Wang, Shuai
    Lu, Zhumao
    AIP ADVANCES, 2025, 15 (01)
  • [5] Deformation Monitoring for High-Voltage Transmission Lines Using Sentinel-1A Data
    Wang, Wenxian
    Wu, Liping
    Gong, Hao
    Fan, Peng
    Wu, Weiqing
    Zhou, Yuantao
    Zhang, Zhengjia
    2018 4TH INTERNATIONAL CONFERENCE ON ENVIRONMENTAL SCIENCE AND MATERIAL APPLICATION, 2019, 252
  • [6] Analysis of transient electromagnetic interference between medium voltage AC and DC overhead transmission lines and cables
    Uhl, Robert
    Monti, Antonello
    Lichtinghagen, Julian
    Moser, Albert
    2016 IEEE INTERNATIONAL ENERGY CONFERENCE (ENERGYCON), 2016,
  • [7] The influence of partition walls inside rooms on the distribution of the electromagnetic field and the quality of transmission data
    Butrylo, Boguslaw
    Choroszucho, Agnieszka
    PRZEGLAD ELEKTROTECHNICZNY, 2009, 85 (07): : 15 - 20
  • [8] Transmission lines fault location estimation based on artificial neural networks and power quality monitoring data
    Hubana, Tank
    2018 IEEE PES INNOVATIVE SMART GRID TECHNOLOGIES CONFERENCE EUROPE (ISGT-EUROPE), 2018,
  • [9] Altitude Correction of Radio Interference of HVdc Transmission Lines Part II: Measured Data Analysis and Altitude Correction
    Zhao, Luxing
    Cui, Xiang
    Xie, Li
    Lu, Jiayu
    He, Kun
    Ju, Yong
    IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 2017, 59 (01) : 284 - 292
  • [10] Statistic analysis of long-term measured data of radio interference on UHV AC demonstration project transmission lines
    Zhang, Yemao
    Zhang, Jiangong
    Wu, Xiong
    Li, Ni
    Xie, Huichun
    Liu, Xingfa
    Gaodianya Jishu/High Voltage Engineering, 2015, 41 (11): : 3708 - 3714