Application of Dynamic Fault Tree Analysis to Prioritize Electric Power Systems in Nuclear Power Plants

被引:13
|
作者
Baek, Sejin [1 ]
Heo, Gyunyoung [1 ]
机构
[1] Kyung Hee Univ, Dept Nucl Engn, 1732 Deogyeong Daero, Yongin 17104, Gyeonggi Do, South Korea
关键词
dynamic fault tree; station blackout; Alternate AC Diesel Generator; multi-unit; SOFTWARE PACKAGE; RELIABILITY; TOOL;
D O I
10.3390/en14144119
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Because the scope of risk assessments at nuclear power plants (NPPs) is being extended both spatially and temporally, conventional, or static fault trees might not be able to express failure mechanisms, or they could be unnecessarily conservative in their expression. Therefore, realistic assessment techniques are needed to adequately capture accident scenarios. In multi-unit probabilistic safety assessment (PSA), fault trees naturally become more complex as the number of units increases. In particular, when considering a shared facility between units of the electric power system (EPS), static fault trees (SFTs) that prioritize a specific unit are limited in implementing interactions between units. However, dynamic fault trees (DFTs) can be available without this limitation by using dynamic gates. Therefore, this study implements SFTs and DFTs for an EPS of two virtual NPPs and compares their results. In addition, to demonstrate the dynamic characteristics of the shared facilities, a station blackout (SBO), which causes the power system to lose its function, is assumed-especially with an inter-unit shared facility, AAC DG (Alternate AC Diesel Generator). To properly model the dynamic characteristics of the shared EPS in DFTs, a modified dynamic gate and algorithm are introduced, and a Monte Carlo simulation is adopted to quantify the DFT models. Through the analysis of the DFT, it is possible to confirm the actual connection priority of AAC DG according to the situation of units in a site. In addition, it is confirmed that some conservative results presented by the SFT can be evaluated from a more realistic perspective by reflecting this.
引用
收藏
页数:17
相关论文
共 50 条
  • [1] REVIEW OF APPLICATION ON DYNAMIC FAULT TREE METHOD IN NUCLEAR POWER PLANTS
    Wu Guohua
    Yuan Diping
    Xiao Yiqing
    Wang Jiaxin
    [J]. PROCEEDINGS OF THE 2020 INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING (ICONE2020), VOL 2, 2020,
  • [2] ELECTRIC POWER SYSTEMS OF FOREIGN NUCLEAR POWER PLANTS
    VINCENS, E
    [J]. NUCLEAR SAFETY, 1964, 5 (03): : 240 - &
  • [3] Modelling of Safety Functions of Nuclear Power Plants Powered by Fault Tree Analysis
    Kamenicky, Jan
    [J]. PROCEEDINGS OF THE 13TH INTERNATIONAL SCIENTIFIC CONFERENCE ELECTRIC POWER ENGINEERING 2012, VOLS 1 AND 2, 2012, : 1305 - 1307
  • [4] The application of principal of information diffusion to fault analysis of electric power systems
    Li, Z
    Li, KT
    [J]. System Simulation and Scientific Computing, Vols 1 and 2, Proceedings, 2005, : 1258 - 1263
  • [5] Application of genetic algorithms to fault diagnosis in nuclear power plants
    Zhou, YP
    Zhou, BQ
    Wu, DX
    [J]. RELIABILITY ENGINEERING & SYSTEM SAFETY, 2000, 67 (02) : 153 - 160
  • [6] SIMPLE FAULT TREE HANDLING-SYSTEM FOR SAFETY ANALYSIS OF NUCLEAR-POWER PLANTS
    WILD, A
    [J]. PROCEEDINGS ANNUAL RELIABILITY AND MAINTAINABILITY SYMPOSIUM, 1981, (NSYM): : 69 - 74
  • [7] Research on fault simulation and fault diagnosis of electric gate valves in nuclear power plants
    Huang, Xue-Ying
    Liu, Yong-Kuo
    Xia, Hong
    Shan, Long-Fei
    [J]. ANNALS OF NUCLEAR ENERGY, 2024, 208
  • [8] APPLICATION OF DIGITAL COMPUTER SYSTEMS IN NUCLEAR POWER PLANTS
    BEVILACQUA, F
    YUILE, EA
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1969, NS16 (01) : 196 - +
  • [10] Fault Tree Analysis for an Inspection Robot in a Nuclear Power Plant
    Ferguson, Thomas A.
    Lu, Lixuan
    [J]. 2ND INTERNATIONAL CONFERENCE ON AUTOMATION, CONTROL AND ROBOTICS ENGINEERING (CACRE 2017), 2017, 235