Adsorptive stripping voltammetric determination of cefepime at the mercury electrode in human urine and cerebrospinal fluid, and differential pulse polarographic determination in serum

被引:24
|
作者
Palacios, FJJ
Mochón, MC
Sánchez, JCJ
Carranza, JH
机构
[1] Univ Seville, Fac Chem, Dept Analyt Chem, E-41012 Seville, Spain
[2] Univ Seville, Fac Pharm, Dept Pharm & Pharm Technol, E-41012 Seville, Spain
关键词
cefepime determination; adsorptive stripping voltammetry; urine; serum; cerebrospinal fluid;
D O I
10.1002/jps.10438
中图分类号
R914 [药物化学];
学科分类号
100701 ;
摘要
The cephalosporin cefepime has been studied by adsorptive stripping voltammetric on the hanging mercury drop electrode, followed by linear sweep voltammetry (staircase). The adsorptive stripping response was evaluated with respect to preconcentration dependence and other variables. The drug is strongly adsorbed in acid media, with maximum adsorption at pH 5.8. The detection limit found was 4.8 x 10(-10) M, with 120-s preconcentration. The relative standard deviation at the 10(-7) M level was 0.93%. This method was applied to the determination of cefepime in human urine and cerebrospinal fluid. Differential pulse polarography has been applied to determination in human serum. (C) 2003 Wiley-Liss, Inc. and the American Pharmacists Association.
引用
收藏
页码:1854 / 1859
页数:6
相关论文
共 50 条
  • [1] DIFFERENTIAL PULSE ADSORPTIVE STRIPPING VOLTAMMETRIC DETERMINATION OF CEFTRIAXONE AT A STATIC MERCURY DROPPING ELECTRODE
    ALTINOZ, S
    TEMIZER, A
    [J]. JOURNAL OF PHARMACEUTICAL SCIENCES, 1990, 79 (04) : 351 - 353
  • [2] Differential pulse adsorptive stripping voltammetric determination of permethrin using hanging mercury drop electrode
    Thriveni, T
    Sreedhar, NY
    [J]. BULLETIN OF ELECTROCHEMISTRY, 2004, 20 (11): : 517 - 523
  • [3] DIFFERENTIAL-PULSE ADSORPTIVE STRIPPING VOLTAMMETRIC DETERMINATION OF SODIUM CROMOGLYCATE AT A HANGING MERCURY DROP ELECTRODE
    MOREIRA, JC
    FOSTER, SE
    RODRIGUES, JA
    FOGG, AG
    [J]. ANALYST, 1992, 117 (06) : 989 - 991
  • [4] Differential pulse adsorptive stripping voltammetric determination of dinoseb and dinoterb at a modified electrode
    Sreedhar, M
    Reddy, LM
    Sirisha, KR
    Reddy, SRJ
    [J]. ANALYTICAL SCIENCES, 2003, 19 (04) : 511 - 516
  • [5] Differential Pulse Adsorptive Stripping Voltammetric Determination of Dinoseb and Dinoterb at a Modified Electrode
    Mallipattu Sreedhar
    Tukiakula Madhusudana Reddy
    Kami Reddy Sirisha
    Srinivasulu Reddy Jayarama Reddy
    [J]. Analytical Sciences, 2003, 19 : 511 - 516
  • [6] Adsorptive stripping voltammetric determination of cefetamet in human urine
    Aleksic, M
    Milovanovic, L
    Kapetanovic, V
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2003, 32 (4-5) : 957 - 966
  • [7] Adsorptive stripping voltammetric determination of venlafaxine in urine with a mercury film microelectrode
    Morais, S
    Ryckaert, CPMCA
    Delerue-Matos, C
    [J]. ANALYTICAL LETTERS, 2003, 36 (11) : 2515 - 2526
  • [8] Adsorptive stripping voltammetric determination of dimenhydrinate at a hanging mercury drop electrode
    Chemistry Department, Faculty of Science, UAE University, Al-Ain, United Arab Emirates
    不详
    [J]. Mikrochim. Acta, 3 (165-171):
  • [9] Adsorptive stripping voltammetric determination of dimenhydrinate at a hanging mercury drop electrode
    Shubietah, RM
    Abu Zuhri, AZ
    Fogg, AG
    [J]. MIKROCHIMICA ACTA, 1999, 130 (03) : 165 - 171
  • [10] Adsorptive stripping voltammetric determination of albendazole at a hanging mercury drop electrode
    Abu Zuhri, AZ
    Hussein, AI
    Musmar, M
    Yaish, S
    [J]. ANALYTICAL LETTERS, 1999, 32 (15) : 2965 - 2975