Comparison of different stylets used for intubation with the C-MAC D-Bladeg Videolaryngoscope: a randomized controlled study

被引:0
|
作者
Omur, Dilek [1 ]
Bayram, Basak [2 ]
Ozbilgin, Sule [1 ]
Hanci, Volkan [1 ]
Kuvaki, Bahar [1 ]
机构
[1] Dokuz Eylul Univ, Dept Anesthesiol & Reanimat, Fac Med, Izmir, Turkey
[2] Dokuz Eylul Univ, Dept Emergency Med, Fac Med, Izmir, Turkey
来源
REVISTA BRASILEIRA DE ANESTESIOLOGIA | 2017年 / 67卷 / 05期
关键词
C-MAC D-Blade (R) vicleotaryngoscopy; Intubation; Stylet; Manikin; AIRWAY MANAGEMENT; DIFFICULT INTUBATION; TRACHEAL INTUBATION; LARYNGOSCOPY; PREDICTORS; OUTCOMES; ROUTINE;
D O I
10.1016/j.bjan.2017.04.008
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Objective: The angle of the C-MAC D-Blade videolaryngoscope, which is used for difficult airway interventions, is not compatible with routinely used endotracheal tubes. Methods: A prospective randomized crossover study was performed comparing five intubation methods for use with standardized airways, including using different stylets or no stylet: Group HS, hockey-stick stylet; Group DS, D-blade type stylet; Group CS, CoPilot videolaryngoscope rigid stylet; Group GEB, gum elastic bougie; and Group NS, no stylet. A manikin was used to simulate difficult intubation with a Storz C-MAC D-Blade (R) videolaryngoscope. The duration of each intubation stage was evaluated. Results: Participants in this study (33 anesthesiology residents and 20 anesthesiology experts) completed a total of 265 intubations. The number of attempts made using no stylet was significantly greater than those made for the other groups (p< 0.05for group NS-group GEB, group NS-group DS, group NS-group CS and group NS-group HS). The duration to pass the vocal cords significantly differed among all groups (p < 0.001). The total intubation duration was shortest when using D-blade stylet, CoPilot stylet and hockey stick stylet. Although no difference was observed between stylet groups, a significant difference was found between each of these three and no stylet and gum elastic bougie (p< 0.05 and p < 0.001, respectively). Conclusion: Use of the correct stylet leads to a more efficient use of the Storz C-MAC D-Blade. In our study, the use of the D-blade stylet, the CoPilot stylet and the hockey stick stylet provided quicker intubation, allowed easier passage of the vocal cords, and decreased the total intubation duration. To confirm the findings of our study, randomized controlled human studies are needed. (C) 2016 Sociedade Brasileira de Anestesiologia. Published by Elsevier Editora Ltda.
引用
收藏
页码:450 / 456
页数:7
相关论文
共 50 条
  • [1] Comparison between bougies and stylets for simulated tracheal intubation with the C-MAC D-blade videolaryngoscope
    Batuwitage, Bisanth
    McDonald, Andrew
    Nishikawa, Koji
    Lythgoe, Daniel
    Mercer, Simon
    Charters, Peter
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2015, 32 (06) : 400 - 405
  • [2] Comparison of Different Types of Stylets with No-Stylet Technique for Intubation with C-MAC D-Blade® Videolaryngoscope in Simulated Difficult Airway: A Prospective Randomised Study
    Goel, Rishika
    Anand, Lakesh Kumar
    Singh, Manpreet
    Jindal, Swati
    Rani, Mala
    Kaur, Arshdeep
    TURKISH JOURNAL OF ANAESTHESIOLOGY AND REANIMATION, 2021, 49 (06) : 445 - 452
  • [3] Comparison of C-MAC videolaryngoscope with Macintosh laryngoscope for nasotracheal intubation by the novice anaesthesiologist
    Ambulkar, Reshma
    Maniraj, S.
    Patil, Sanika J.
    Divatia, Jigeeshu
    INDIAN JOURNAL OF ANAESTHESIA, 2022, 66 (12) : 865 - 868
  • [4] Comparison of the success of two techniques for the endotracheal intubation with C-Mac videolaryngoscope straight blade in paediatric patients: a randomized study
    Sinha, Renu
    Sharma, Ankur
    Ray, Bikash Ranjan
    Pandey, Ravinder Kumar
    Darlong, Vanlal
    Chandralekha, C.
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2015, 59 : 16 - 16
  • [5] Comparison of the C-MAC D-Blade videolaryngoscope and direct laryngoscope in pediatric patients: Randomized controlled trial
    Hajiyeva, Konul
    Can, Ozlem Selvi
    Baytas, Volkan
    Guclu, Cigdem Yildirim
    ULUSAL TRAVMA VE ACIL CERRAHI DERGISI-TURKISH JOURNAL OF TRAUMA & EMERGENCY SURGERY, 2021, 27 (04): : 421 - 426
  • [6] Hemodynamic responses to tracheal intubation with Bonfils compared to C-MAC videolaryngoscope: a randomized trial
    Youssef Ezhar
    Frederick D’Aragon
    Pablo Echave
    BMC Anesthesiology, 18
  • [7] Hemodynamic responses to tracheal intubation with Bonfils compared to C-MAC videolaryngoscope: a randomized trial
    Ezhar, Youssef
    D'Aragon, Frederick
    Echave, Pablo
    BMC ANESTHESIOLOGY, 2018, 18
  • [8] The C-MAC videolaryngoscope for prehospital emergency intubation: a prospective, multicentre, observational study
    Cavus, Erol
    Callies, Andreas
    Doerges, Volker
    Heller, Gilbert
    Merz, Sabine
    Roesch, Peter
    Steinfath, Markus
    Helm, Matthias
    EMERGENCY MEDICINE JOURNAL, 2011, 28 (08) : 650 - 653
  • [9] Comparison of C-MAC Videolaryngoscope, GlideScope Ranger and conventional laryngoscopy for tracheal intubation in patients with a predicted difficult airway - A randomized controlled trial
    Reifferscheid, F.
    Michelson, I.
    Doerges, V.
    Steinfath, M.
    Bein, B.
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2010, 27 (01) : 263 - 264
  • [10] Comparison of ease of intubation in right and left lateral position using C-MAC videolaryngoscope
    Bhat, Ravi
    Sanickop, C. S.
    Dhorigoll, M. G.
    Umrani, Vijay
    Suresh, S. N.
    ANAESTHESIA PAIN & INTENSIVE CARE, 2013, 17 (02) : 162 - 165