Grounding Type and Application for Transmission Line Pole and Tower

被引:0
|
作者
Xiaoyan Huang [1 ]
机构
[1] Sichuan Coll Architectural Technol, Deyang 618000, Sichuan, Peoples R China
关键词
Soil resistivity; Reducing agent; Grounding device; Grounding module;
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The line project of pole and tower grounding device in Sichuan Province are analyzed in this paper, It points out some problems transmission line tower grounding existing at present. Several kinds of grounding types for transmission line pole and tower are discussed in detail. A closed loop grounding device is used in paddy field and residential area with the actual terrain, radiation type grounding device add reducing resistance agent or the grounding module in the high soil resistivity area, to better realize the safe and reliable operation of the power supply line.
引用
收藏
页码:239 / 244
页数:6
相关论文
共 50 条
  • [1] Composite Grounding Application of Transmission Line Tower with Flexible Graphite Grounding Material
    Liu, Hongtao
    Zhang, Lei
    Xiong, Jia
    Cui, Zhenxing
    Yang, Qi
    2ND INTERNATIONAL CONFERENCE ON DESIGN, MATERIALS, AND MANUFACTURING, 2017, 220
  • [2] Some Notes on the Impulse Characteristics of Type A Grounding of Transmission Line Tower
    Bajramovic, Z.
    Mujezinovic, A.
    Turkovic, I.
    Avdakovic, S.
    Carsimamovic, S.
    Veledar, M.
    2017 2ND INTERNATIONAL MULTIDISCIPLINARY CONFERENCE ON COMPUTER AND ENERGY SCIENCE (SPLITECH), 2017, : 255 - 260
  • [3] Study on the Distribution Optimization Scheme of the Grounding Device of the Transmission Line Pole Tower Next to the Fish Pond
    Gao, Zhenyu
    Huang, Jisheng
    Ma, Yutang
    Liu, Xintong
    Ren, Haoyan
    2020 5TH ASIA CONFERENCE ON POWER AND ELECTRICAL ENGINEERING (ACPEE 2020), 2020, : 1800 - 1804
  • [4] Influence of transmission line tower grounding impedance to the line flashover rate
    Stojkovic, Z
    Savic, MS
    EUROPEAN TRANSACTIONS ON ELECTRICAL POWER, 1999, 9 (04): : 261 - 270
  • [5] The impulse grounding impedance computation in HVDe transmission line tower
    Li Tian-wei
    Xiang Yang
    Zhao Yu-ming
    2013 IEEE PES ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2013,
  • [6] TRANSMISSION-LINE TOWER GROUNDING PERFORMANCE IN NONUNIFORM SOIL
    DAWALIBI, F
    FINNEY, WG
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1980, 99 (02): : 471 - 479
  • [7] Application of tower grounding device equivalent model in the calculation of transmission line back-flashover
    Chen, Huaifei
    Cai, Hansheng
    Ni, Yang
    Jia, Lei
    Lu, Hailiang
    Liu, Gang
    Lan, Lei
    JOURNAL OF ENGINEERING-JOE, 2019, (16): : 1830 - 1835
  • [8] Research on Soft Grounding Material with High Conductivity in Transmission Line Tower Grounding Network
    Wu Guoliang
    Luo Yongqin
    2016 2ND INTERNATIONAL CONFERENCE ON MECHANICAL, ELECTRONIC AND INFORMATION TECHNOLOGY ENGINEERING (ICMITE 2016), 2016, : 346 - 350
  • [9] Research on Evaluation Method and Application of Grounding State of Transmission Tower
    Guo, Lei
    Yan, Zhe
    Peng, Honggang
    2023 2ND ASIAN CONFERENCE ON FRONTIERS OF POWER AND ENERGY, ACFPE, 2023, : 531 - 535
  • [10] Quick calculation of the grounding resistance of a typical 110 kV transmission line tower grounding system
    Trifunovic, J.
    Kostic, M.
    ELECTRIC POWER SYSTEMS RESEARCH, 2016, 131 : 178 - 186