Diaphragm dysfunction detected with ultrasound to predict noninvasive mechanical ventilation failure: A prospective cohort study

被引:16
|
作者
Kocyigit, Huseyin [1 ]
Gunalp, Muge [2 ]
Genc, Sinan [2 ]
Oguz, Ahmet Burak [2 ]
Koca, Ayca [2 ]
Polat, Onur [2 ]
机构
[1] Diyarbakir Selahaddin Eyyubi State Hosp, Dept Emergency Med, Diyarbakir, Turkey
[2] Ankara Univ, Sch Med, Dept Emergency Med, Ankara, Turkey
来源
关键词
COPD; Diaphragmatic dysfunction; Noninvasive mechanical ventilation; POCUS; OBSTRUCTIVE PULMONARY-DISEASE; EXACERBATIONS; OUTCOMES; COPD;
D O I
10.1016/j.ajem.2020.08.014
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: This study aimed to examine the use of point-of-care ultrasonography (POCUS) in detecting diaphragmatic dysfunction (DD) and evaluate its ability to predict noninvasive mechanical ventilation (NIV) failure in patients presented to the emergency department with acute exacerbation of chronic obstructive pulmonary disease (AECOPD). Methods: In this prospective cohort study, the diaphragm was examined using POCUS in patients with AECOPD. DD was defined as a diaphragm thickening fraction of less than 20% during spontaneous breathing. NIV failure was the primary outcome of the study, and duration of hospital stay and in-hospital mortality were the secondary outcomes. Specificity, sensitivity, positive predictive value, and negative predictive value were estimated for predicting NIV failure in DD and evaluating the diagnostic performance of POCUS. Results: 60 patients were enrolled the study. NIV failure was found in 11 (73.3%) of 15 patients with DD and in 2 (4.4%) of 45 patients without DD. In predicting NIV failure, DD had a sensitivity of 84.6% (95% confidence interval [CI]:54.6-98.1), specificity of 91.5% (95% CI:79.6-97.6), positive predictive value of 73.3% (95% CI:51.2-87.8), and negative predictive value of 95.6% (95% CI:85.7-98.7). The duration of hospital stay was not different between groups (p = .065). No in-hospital mortality was seen in patients without DD. Conclusions: DD has high sensitivity and specificity in predicting NIV failure in patients admitted to the emergency department with AECOPD. DD can be assessed by an experienced clinician noninvasively using POCUS in emergency departments. (c) 2020 Elsevier Inc. All rights reserved.
引用
收藏
页码:202 / 207
页数:6
相关论文
共 50 条
  • [1] Use of Neonatal Chest Ultrasound to Predict Noninvasive Ventilation Failure
    Raimondi, Francesco
    Migliaro, Fiorella
    Sodano, Angela
    Ferrara, Teresa
    Lama, Silvia
    Vallone, Gianfranco
    Capasso, Letizia
    PEDIATRICS, 2014, 134 (04) : E1089 - E1094
  • [2] Lung ultrasound to predict mechanical ventilation weaning failure
    LY Delgado Ayala
    O Torres
    A Sanchez-Calzada
    JL Navarro
    A Torres
    R Gastelum
    P Romano Albornoz
    M Arcos
    EE Monares
    J Aguirre
    J Franco
    Intensive Care Medicine Experimental, 3 (Suppl 1)
  • [3] Is It Possible to Predict the Failure of Noninvasive Mechanical Ventilation for Acute Respiratory Failure Due to Pneumonia?
    Gurgun, Alev
    Nesil, Imren
    Ekren, Pervin Korkmaz
    Uysal, Funda Elmas
    Bacakoglu, Feza
    CHEST, 2015, 148 (04)
  • [4] Ultrasonography to Access Diaphragm Dysfunction and Predict the Success of Mechanical Ventilation Weaning in Critical Care
    Marques, Marta Rafael
    Pereira, Jose Manuel
    Paiva, Jose Artur
    de Casasola-Sanchez, Gonzalo Garcia
    Tung-Chen, Yale
    JOURNAL OF ULTRASOUND IN MEDICINE, 2024, 43 (02) : 223 - 236
  • [5] Inability of Diaphragm Ultrasound to Predict Extubation Failure A Multicenter Study
    Vivier, Emmanuel
    Muller, Michel
    Putegnat, Jean-Baptiste
    Steyer, Julie
    Barrau, Stephanie
    Boissier, Florence
    Bourdin, Gael
    Mekontso-Dessap, Armand
    Levrat, Albrice
    Pommier, Christian
    Thille, Arnaud W.
    CHEST, 2019, 155 (06) : 1131 - 1139
  • [6] Early Serial Changes on Diaphragm Muscle Ultrasound May Predict Duration of Mechanical Ventilation
    Sarwal Aarti
    Bringolf, Karamie
    Cartwright, Michael
    Hsu Fang-chi
    Berry, M.
    Bowton, David
    Dhar, Sanjay
    Morris, Peter
    CRITICAL CARE MEDICINE, 2013, 41 (12)
  • [7] Diaphragm ultrasound in weaning from mechanical ventilation: a last step to predict successful extubation?
    Di Costanzo, Domenica
    Mazza, Mariano
    Esquinas, Antonio
    ACUTE AND CRITICAL CARE, 2022, 37 (04) : 681 - 682
  • [8] Diaphragm atrophy during invasive mechanical ventilation is related to extubation failure in preterm infants: An ultrasound study
    Nobile, Stefano
    Sbordone, Annamaria
    Salce, Nicola
    Patti, Maria Letizia
    Perri, Alessandro
    Fattore, Simona
    Prontera, Giorgia
    Giordano, Lucia
    Tana, Milena
    Vento, Giovanni
    PEDIATRIC PULMONOLOGY, 2024, 59 (04) : 855 - 862
  • [9] Diaphragm Ultrasound in Weaning From Mechanical Ventilation
    Kilaru, Deepti
    Panebianco, Nova
    Baston, Cameron
    CHEST, 2021, 159 (03) : 1166 - 1172
  • [10] Lung ultrasound findings predict weaning failure from mechanical ventilation
    AC Pecanha Antonio
    P Souza Castro
    LF Schulz
    J Maccari
    R Oliveira
    C Teixeira
    M Knorst
    Critical Care, 18 (Suppl 1):