The influence of chemical nature on the corrosion behaviour of some dental alloys in Fusayama-Meyer artificial saliva

被引:0
|
作者
Prioteasa, P. [1 ]
Ibris, N.
Visan, T.
机构
[1] INCDIE ICPE CA, Inst Elect Engn Adv Res, Bucharest, Romania
[2] Univ Politehn Bucuresti, Bucharest, Romania
来源
JOURNAL OF OPTOELECTRONICS AND ADVANCED MATERIALS | 2007年 / 9卷 / 11期
关键词
dental alloys; corrosion; artificial saliva; biocompatibility;
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The paper presents the influence of chemical nature on the corrosion of dental alloys in Fusayama - Meyer artificial saliva with fluoride ions content, at human body temperature (37 degrees C). From evolution of open-circuit potential/time and polarization curves, as well as by processing Nyquist and Bode impedance plots, it was concluded that the biocompatibility of dental alloys depends mainly on the occurence of passivating film. Better electrochemical parameters were obtained for greater Cr content in the non-noble alloy, By adding of fluoride ions, the passive film was also developed, whereas the corrosion resistance is diminished.
引用
收藏
页码:3405 / 3410
页数:6
相关论文
共 48 条
  • [1] The electrochemical behaviour of some unnoble alloys in fusayama artificial saliva
    Sutiman, Daniel Mircea
    Mareci, Daniel
    Nechita, Teodor Mircea
    Iordache, Ioan
    Rosca, Julia Claudia Mirza
    MACEDONIAN JOURNAL OF CHEMISTRY AND CHEMICAL ENGINEERING, 2007, 26 (01) : 57 - 63
  • [2] ELECTROCHEMICAL BEHAVIOUR OF ALLOYS AND DENTAL BRAZES USED IN PROSTHESIS FIXED IN A FUSAYAMA-MEYERS ARTIFICIAL SALIVA
    de March, Pascal
    Berthod, Patrice
    Dervisevic, Birsena
    Vallata, Aude
    UNIVERSITY POLITEHNICA OF BUCHAREST SCIENTIFIC BULLETIN SERIES B-CHEMISTRY AND MATERIALS SCIENCE, 2010, 72 (02): : 53 - 68
  • [3] CORROSION BEHAVIOR OF NEW BETA TYPE TITANIUM ALLOY, TI-29NB-13TA-4.6ZR (TNTZ) IN FUSAYAMA-MEYER ARTIFICIAL SALIVA SOLUTION
    Gunawarman
    Giatmana, Dani D.
    Ilhamdi
    Affi, Jon
    Yetri, Yuli
    Niinomi, Mitsuo
    Nakai, Masaaki
    JOURNAL OF ENGINEERING SCIENCE AND TECHNOLOGY, 2018, 13 (05) : 1274 - 1281
  • [4] CORROSION RATE STUDIES - MEASUREMENTS OF CORROSION RATES OF SOME NONPRECIOUS DENTAL ALLOYS IN ARTIFICIAL SALIVA
    WIEGMANHO, L
    KETELAAR, JAA
    JOURNAL OF DENTISTRY, 1987, 15 (04) : 166 - 170
  • [5] Corrosion of dental alloys in artificial saliva with Streptococcus mutans
    Lu, Chunhui
    Zheng, Yuanli
    Zhong, Qun
    PLOS ONE, 2017, 12 (03):
  • [6] Enhanced corrosion resistance of harmonic structured β-type Ti-25Nb-25Zr alloy in aerated Fusayama-Meyer's simulated saliva solution
    Banik, D.
    Baditela, Teja Sri
    Mandal, Saikat
    Fujiwara, H.
    Ameyama, K.
    Mondal, K.
    MATERIALS LETTERS, 2024, 377
  • [7] EIS diagnosis of some dental alloys in artificial saliva
    Mareci, Daniel
    Ungureanu, Gina
    Aelenei, Neculai
    Chelariu, Romeo
    Mirza Rosca, Julia Claudia
    ENVIRONMENTAL ENGINEERING AND MANAGEMENT JOURNAL, 2007, 6 (04): : 313 - 317
  • [8] Electrochemical corrosion behavior of dental/implant alloys in artificial saliva
    Sharma, Mohit
    Kumar, A. V. Ramesh
    Singh, Nirbhay
    Adya, Nidhi
    Saluja, Bobin
    JOURNAL OF MATERIALS ENGINEERING AND PERFORMANCE, 2008, 17 (05) : 695 - 701
  • [9] COMPARISON OF THE CORROSION PROPERTIES OF CoCrMo DENTAL ALLOYS IN ARTIFICIAL SALIVA
    Kosec, Tadeja
    Leban, Mirjam Bajt
    Kurnik, Matej
    Kopac, Igor
    MATERIALI IN TEHNOLOGIJE, 2021, 55 (06): : 819 - 824
  • [10] Electrochemical Corrosion Behavior of Dental/Implant Alloys in Artificial Saliva
    Mohit Sharma
    A.V. Ramesh Kumar
    Nirbhay Singh
    Nidhi Adya
    Bobin Saluja
    Journal of Materials Engineering and Performance, 2008, 17 : 695 - 701