Battery powered laser-induced plasma spectrometer for elemental determinations

被引:56
|
作者
Castle, BC [1 ]
Knight, AK [1 ]
Visser, K [1 ]
Smith, BW [1 ]
Winefordner, JD [1 ]
机构
[1] Univ Florida, Dept Chem, Gainesville, FL 32611 USA
关键词
laser-induced breakdown spectrometry; laser plasma imaging; steel; ore; organic samples; calcium; manganese;
D O I
10.1039/a708844b
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A battery powered, portable laser-induced breakdown spectrometry instrument with a low pulse energy laser and a low resolution, non-gated spectrometer is evaluated. Improvements in the instrument probe design mere accomplished through studies of the plasma spatial development, lens-to-sample distance effects and spatial filtering. The prototype was evaluated on paint, steel, ores, and organic samples. Limits of detection ranged from 0.016% for Mn in MST SRM steel to 0.13% for Ca in NIST SRM organic samples. Acceptable precision (0.4-4.9%) mas obtained for steel, ore and organic SRM samples. The poorer precision (4.0-44.1%) obtained for the detection of Pb in paint can be attributed to the heterogeneity of the samples.
引用
收藏
页码:589 / 595
页数:7
相关论文
共 50 条
  • [1] Battery powered laser-induced plasma spectrometer for elemental determinations
    Univ of Florida, Gainesville, United States
    J Anal At Spectrom, 7 (589-595):
  • [2] Handheld Laser-Induced Breakdown Spectrometer for In-field Elemental Analysis
    Day, David
    Sackett, Don
    SPECTROSCOPY, 2014, : 13 - 13
  • [3] Study on the Laser-Induced Plasma Spectroscopy Based on the Echelle Spectrometer
    Zhang Rui
    Zhu Ji-wei
    Liu Jian-li
    Cui Ji-cheng
    Li Xiao-tian
    Bayanheshig
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2018, 38 (05) : 1605 - 1609
  • [4] Sensitive elemental analysis of aqueous colloids by laser-induced plasma spectroscopy
    Pu, XY
    Ma, WY
    Cheung, NH
    APPLIED PHYSICS LETTERS, 2003, 83 (16) : 3416 - 3418
  • [5] New procedure for quantitative elemental analysis by laser-induced plasma spectroscopy
    Ciucci, A
    Corsi, M
    Palleschi, V
    Rastelli, S
    Salvetti, A
    Tognoni, E
    APPLIED SPECTROSCOPY, 1999, 53 (08) : 960 - 964
  • [6] A COMPUTER-BASED TRIGGER SYSTEM FOR A LASER-INDUCED PLASMA SPECTROMETER
    CHAU, FT
    TAM, KY
    LAU, KS
    WONG, KH
    COMPUTERS & CHEMISTRY, 1993, 17 (01): : 11 - 17
  • [7] Portable, battery-powered, tungsten coil atomic absorption spectrometer for lead determinations
    Sanford, CL
    Thomas, SE
    Jones, BT
    APPLIED SPECTROSCOPY, 1996, 50 (02) : 174 - 181
  • [8] Elemental analysis of bead samples using a laser-induced plasma at low pressure
    Lie, TJ
    Kurniawan, KH
    Kurniawan, DP
    Pardede, M
    Suliyanti, MM
    Khumaeni, A
    Natiq, SA
    Abdulmadjid, SN
    Lee, YI
    Kagawa, K
    Idris, N
    Tjia, MO
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2006, 61 (01) : 104 - 112
  • [9] Remote laser-induced plasma spectrometry for elemental analysis of samples of environmental interest
    López-Moreno, C
    Palanco, S
    Laserna, JJ
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2004, 19 (11) : 1479 - 1484