Simulation-based framework to evaluate resistivity of cooling strategies in buildings against overheating impact of climate change

被引:38
|
作者
Rahif, R. [1 ]
Hamdy, M. [2 ]
Homaei, S. [2 ]
Zhang, C. [3 ]
Holzer, P. [4 ]
Attia, S. [1 ]
机构
[1] Univ Liege, Fac Appl Sci, Dept UEE, Sustainable Bldg Design Lab, Liege, Belgium
[2] Norwegian Univ Sci & Technol, Dept Civil & Environm Engn, Trondheim, Norway
[3] Aalborg Univ, Dept Built Environm, Thomas Manns Vej 23, DK-9220 Aalborg, Denmark
[4] Inst Bldg Res & Innovat, Wipplingerstr 23-03, A-1010 Vienna, Austria
关键词
Thermal comfort; Global warming; Overheating; Cooling strategy; Climate change; AIR-CONDITIONING SYSTEM; ENERGY PERFORMANCE; OFFICE BUILDINGS; THERMAL COMFORT; CONSUMPTION; VAV; BENCHMARKING; MITIGATION; DWELLINGS; TYPOLOGY;
D O I
10.1016/j.buildenv.2021.108599
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Over the last decades overheating in buildings has become a major concern. The situation is expected to worsen due to the current rate of climate change. Many efforts have been made to evaluate the future thermal performance of buildings and cooling technologies. In this paper, the term "climate change overheating resistivity " of cooling strategies is defined, and the calculation method is provided. A comprehensive simulation-based framework is then introduced, enabling the evaluation of a wide range of active and passive cooling strategies. The framework is based on the Indoor Overheating Degree (IOD), Ambient Warmness Degree (AWD), and Climate Change Overheating Resistivity (CCOR) as principal indicators allowing a multi-zonal approach in the quantification of indoor overheating risk and resistivity to climate change. To test the proposed framework, two air-based cooling strategies including a Variable Refrigerant Flow (VRF) unit coupled with a Dedicated Outdoor Air System (DOAS) (C01) and a Variable Air Volume (VAV) system (C02) are compared in six different locations/climates. The case study is a shoe box model representing a double-zone office building. In general, the C01 shows higher CCOR values between 2.04 and 19.16 than the C02 in different locations. Therefore, the C01 shows superior resistivity to the overheating impact of climate change compared to C02. The maximum CCOR value of 37.46 is resulted for the C01 in Brussels, representing the most resistant case, whereas the minimum CCOR value of 9.24 is achieved for the C02 in Toronto, representing the least resistant case.
引用
收藏
页数:18
相关论文
共 50 条
  • [1] An innovative simulation-based methodology for evaluating cooling strategies in climate change-induced overheating
    Karimi, Alireza
    Mohajerani, Mostafa
    Moslehi, Hamed
    Mohammadzadeh, Negar
    Martinez, Antonio Garcia
    Rangel, David Moreno
    [J]. JOURNAL OF BUILDING ENGINEERING, 2023, 80
  • [2] RETRACTION: An innovative simulation-based methodology for evaluating cooling strategies in climate change-induced overheating
    Karimi, Alireza
    Mohajerani, Mostafa
    Moslehi, Hamed
    Mohammadzadeh, Negar
    Martinez, Antonio Garcia
    Rangel, David Moreno
    [J]. JOURNAL OF BUILDING ENGINEERING, 2024, 96
  • [3] A simulation-based framework to evaluate strategies for managing global inbound supply risk
    Colicchia, Claudia
    Dallari, Fabrizio
    Melacini, Marco
    [J]. INTERNATIONAL JOURNAL OF LOGISTICS-RESEARCH AND APPLICATIONS, 2011, 14 (06) : 371 - 384
  • [4] An open-source framework for simulation-based testing of buildings control strategies
    Huang, Sen
    Lutes, Robert
    Faulkner, Cary A.
    Vrabie, Draguna L.
    Katipamula, Srinivas
    Zuo, Wangda
    [J]. JOURNAL OF BUILDING PERFORMANCE SIMULATION, 2023, 16 (06) : 631 - 643
  • [5] Ventilative cooling of residential buildings in China: A simulation-based evaluation of lightweight modular integrated constructions considering climate change
    Hu, Yan
    Ai, Zhengtao
    Wargocki, Pawel
    Chang, Yufan
    Zhang, Guoqiang
    [J]. ENERGY AND BUILDINGS, 2024, 317
  • [6] Simulation-based coefficients for adjusting climate impact on energy consumption of commercial buildings
    Na Wang
    Atefe Makhmalbaf
    Viraj Srivastava
    John E. Hathaway
    [J]. Building Simulation, 2017, 10 : 309 - 322
  • [7] Simulation-based coefficients for adjusting climate impact on energy consumption of commercial buildings
    Wang, Na
    Makhmalbaf, Atefe
    Srivastava, Viraj
    Hathaway, John E.
    [J]. BUILDING SIMULATION, 2017, 10 (03) : 309 - 322
  • [8] Building optimization testing framework (BOPTEST) for simulation-based benchmarking of control strategies in buildings
    Blum, David
    Arroyo, Javier
    Huang, Sen
    Drgona, Jan
    Jorissen, Filip
    Walnum, Harald Taxt
    Chen, Yan
    Benne, Kyle
    Vrabie, Draguna
    Wetter, Michael
    Helsen, Lieve
    [J]. JOURNAL OF BUILDING PERFORMANCE SIMULATION, 2021, 14 (05) : 586 - 610
  • [9] Simulation-Based Evaluation and Optimization of Control Strategies in Buildings
    Kontes, Georgios D.
    Giannakis, Georgios I.
    Sanchez, Victor
    de Agustin-Camacho, Pablo
    Romero-Amorrortu, Ander
    Panagiotidou, Natalia
    Rovas, Dimitrios V.
    Steiger, Simone
    Mutschler, Christopher
    Gruen, Gunnar
    [J]. ENERGIES, 2018, 11 (12)
  • [10] Impact assessment of climate change on buildings in Paraguay—Overheating risk under different future climate scenarios
    Fabiana Silvero
    Camilla Lops
    Sergio Montelpare
    Fernanda Rodrigues
    [J]. Building Simulation, 2019, 12 : 943 - 960