CALCULATION OF FRICTION FACTORS AND NUSSELT NUMBERS FOR TWISTED ELLIPTICAL TUBE HEAT EXCHANGERS USING NEK5000

被引:0
|
作者
Shaver, Dillon R. [1 ]
Carasik, Lane B. [2 ]
Merzari, Elia [1 ]
Salpeter, Nate [2 ]
Blandford, Edward [2 ]
机构
[1] Argonne Natl Lab, 9700 S Cass Ave, Argonne, IL 60439 USA
[2] Kairos Power LLC, Oakland, CA USA
关键词
NUMERICAL-SIMULATION; FLOW;
D O I
暂无
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
The development of fluoride salt-cooled high-temperature reactors (FHRs) for nuclear power generation relies on the development of new technologies. Of the potential options being explored, twisted elliptical tube geometries for heat exchanger design are promising based on usage in other industries. They are expected to offer significant enhancement in heat transfer with only a marginal increase in frictional losses. This allows them to be deployed in relatively compact designs that are well suited for FHRs. The presented work focuses on the computational fluid dynamics (CFD) simulations of heated molten salt flows through various twisted elliptical tube geometries at low modified Froude numbers. The objectives of this work are to evaluate the available correlations at lower Froude numbers and to determine the impact of using non-zero tube to tube spacing to resolve contact points or numerical singularities for future CFD simulations efforts. The spectral element CFD code Nek5000 was used for all simulations, which were performed in periodic domains of triangular (hexagonal) and square unit cells surrounding a single tube through a complete twist using an explicit filtering large eddy simulation (LES) method. Simulations were used to parametrically test the effects of tube-to-tube spacing for laminar and turbulent flow regimes on frictional pressure drop and heat transfer. The tested Reynolds numbers covered both laminar flow and fully developed turbulent flow (90 < Re < 12200). The tested S-L/d(max) ratios cover the range of 1.02 to 1.08 for both unit cell types. At moderate Reynolds number and comparitively high modified Froude number, excellent agreement for the Nusselt number was observed between simulations and the applicable correlation. As Froude number was decreased towards the bounds of the correlation, the agreement worsened. Cases were then simulated at low Froude number, testing the effects of tube spacing. It was determined that the laminar case for the square unit cell is the most affected by increasing S-L/d(max) and the gap size should be minimized to mitigate this. Whereas in the triangular unit cell the laminar flow regime is more significantly impacted by increasing S-L/d(max) compared to the turbulent flow regime which was only marginally impacted.
引用
收藏
页数:12
相关论文
共 21 条
  • [1] Calculation of Friction Factors and Nusselt Numbers for Twisted Elliptical Tube Heat Exchangers Using Nek5000
    Shaver, Dillon R.
    Carasik, Lane B.
    Merzari, Elia
    Salpeter, Nate
    Blandford, Edward
    [J]. JOURNAL OF FLUIDS ENGINEERING-TRANSACTIONS OF THE ASME, 2019, 141 (07):
  • [2] CFD Analysis for a Twisted Elliptical Double Tube Heat Exchangers Integrated with a Twisted Tape
    Khaled, Riyam Ali
    Mushatet, Khudheyer S.
    [J]. INTERNATIONAL JOURNAL OF HEAT AND TECHNOLOGY, 2023, 41 (05) : 1301 - 1308
  • [3] Finite element calculation of friction factors and nusselt numbers for rectangular ducts
    du Toit, CG
    [J]. CHT'01: ADVANCES IN COMPUTATIONAL HEAT TRANSFER II, VOLS 1 AND 2, PROCEEDINGS, 2001, : 583 - 590
  • [4] Calculation of friction factors and Nusselt numbers for laminar flow in rectangular ducts using finite elements
    du Toit, CG
    [J]. NUMERICAL HEAT TRANSFER PART B-FUNDAMENTALS, 2002, 41 (3-4) : 397 - 407
  • [5] Performance investigation on twisted elliptical tube heat exchangers with coupling-vortex square tube layout
    Gu, Huaduo
    Chen, Yaping
    Wu, Jiafeng
    Sunden, Bengt
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2020, 151
  • [6] Air-Side Nusselt Numbers and Friction Factor's Individual Correlations of Finned Heat Exchangers
    Marcinkowski, Mateusz
    Taler, Dawid
    Taler, Jan
    Weglarz, Katarzyna
    [J]. ENERGIES, 2022, 15 (15)
  • [7] Combined effects of inlet conditions and assembly accuracy on Nusselt and friction factors of plate heat exchangers
    dos Santos, F. J.
    Martins, G. S. M.
    Strobel, M.
    Beckedorff, L.
    de Paiva, K. V.
    Oliveira, J. L. G.
    [J]. INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2024, 197
  • [8] New equations for Nusselt number and friction factor of the annulus side of the conically coiled tubes in tube heat exchangers
    Ali, Mohamed
    Rad, Milad Mansouri
    Nuhait, Abdullah
    Almuzaiqer, Redhwan
    Alimoradi, Ashkan
    Tlili, Iskander
    [J]. APPLIED THERMAL ENGINEERING, 2020, 164
  • [9] Influence of alternating V-rows tube layout on thermal-hydraulic characteristics of twisted elliptical tube heat exchangers
    Gu, Huaduo
    Chen, Yaping
    Sunden, Bengt
    Wu, Jiafeng
    Song, Ning
    Su, Jindong
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2020, 159
  • [10] Performance intensification of tubular heat exchangers using compound twisted-tape and twisted-tube
    Khoshvaght-Aliabadi, Morteza
    Feizabadi, Amir
    [J]. CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 2020, 148 (148)