Ultrasensitive Detection of Bacterial Protein Toxins on Patterned Microarray via Surface Plasmon Resonance Imaging with Signal Amplification by Conjugate Nanoparticle Clusters

被引:24
|
作者
Lambert, Alexander [1 ]
Yang, Zhanjun [1 ]
Cheng, Wei [1 ]
Lu, Zhenda [3 ]
Liu, Ying [2 ]
Cheng, Quan [1 ]
机构
[1] Univ Calif Riverside, Dept Chem, Riverside, CA 92521 USA
[2] Nanjing Univ, Dept Chem, Nanjing 210023, Jiangsu, Peoples R China
[3] Nanjing Univ, Coll Engn & Appl Sci, Nanjing 210023, Jiangsu, Peoples R China
来源
ACS SENSORS | 2018年 / 3卷 / 09期
基金
美国国家科学基金会; 中国国家自然科学基金; 新加坡国家研究基金会;
关键词
surface plasmon resonance; SPR imaging; nanoparticle amplification; microarray; plasmonic microchip; LABEL-FREE ANALYSIS; GOLD NANOPARTICLES; CHOLERA-TOXIN; SENSITIVE DETECTION; LIPID-MEMBRANE; BIOSENSOR; ARRAYS; SENSOR; GLYCONANOPARTICLES; NANOCRYSTALS;
D O I
10.1021/acssensors.8b00260
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Sensitive detection and monitoring of biological interactions in a high throughput, multiplexed array format has numerous advantages. We report here a method to enhance detection sensitivity in surface plasmon resonance (SPR) spectroscopy and SPR imaging via the effect of accumulation of conjugated nanoparticles of varying sizes. Bacterial cholera toxin (CT) was chosen for the demonstration of enhanced immunoassay by SPR After immobilization of CT on a gold surface, specific recognition is achieved by biotinylated anti-CT. The signal is amplified by the attachment of biotinylated 20 nm AuNP via streptavidin bridge, followed by attachment of 5 nm streptavidin-functionalized Fe3O4 NP to the AuNP-biotin surface. The continuous surface binding of two differently sized conjugated nanoparticles effectively increases their packing density on surface and significantly improves SPR detection sensitivity, allowing quantitative measurement of CT at very low concentration. The dense packing of conjugated nanoparticles on the surface was confirmed by atomic force microscopy characterization. SPR imaging of the immunoassay for high-throughput analysis utilized an Au-well microarray that attenuated the background resonance interference on the resulting images. A calibration curve of conjugated nanoparticle binding signal amplification for CT detection based on surface coverage has been obtained that shows a correlation in a range from 6.31 X 10(-16) to 2.51 X 10(-13) mol/cm(2) with the limit of detection of 5.01 x 10(-16) mol/cm(2). The absolute quantity of detection limit using SPR imaging was 0.25 fmol. The versatile nanoparticles and biotin-streptavidin interaction used here should allow adaptation of this enhancement method to many other systems that include DNA, RNA, peptides, and carbohydrates, opening new avenues for ultrasensitive analysis of biomolecules.
引用
收藏
页码:1639 / 1646
页数:15
相关论文
共 50 条
  • [1] Ultrasensitive detection of DNA by PNA and nanoparticle-enhanced surface plasmon resonance imaging
    D'Agata, Roberta
    Corradini, Roberto
    Grasso, Giuseppe
    Marchelli, Rosangela
    Spoto, Giuseppe
    CHEMBIOCHEM, 2008, 9 (13) : 2067 - 2070
  • [2] Development of surface plasmon resonance imaging (SPRi) technique for detection of bacterial toxins.
    Cheng, Q
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2005, 229 : U156 - U156
  • [3] Ultrasensitive detection of testosterone using conjugate linker technology in a nanoparticle-enhanced surface plasmon resonance biosensor
    Mitchell, John S.
    Lowe, Tim E.
    BIOSENSORS & BIOELECTRONICS, 2009, 24 (07): : 2177 - 2183
  • [4] Ultrasensitive Microarray Detection of Short RNA Sequences with Enzymatically Modified Nanoparticles and Surface Plasmon Resonance Imaging Measurements
    Zhou, Wen-Juan
    Chen, Yulin
    Corn, Robert M.
    ANALYTICAL CHEMISTRY, 2011, 83 (10) : 3897 - 3902
  • [5] Near Infrared Surface Plasmon Resonance Phase Imaging and Nanoparticle-Enhanced Surface Plasmon Resonance Phase Imaging for Ultrasensitive Protein and DNA Biosensing with Oligonucleotide and Aptamer Microarrays
    Zhou, Wen-Juan
    Halpern, Aaron R.
    Seefeld, Ting H.
    Corn, Robert M.
    ANALYTICAL CHEMISTRY, 2012, 84 (01) : 440 - 445
  • [6] Ultrasensitive detection of non-amplified genomic DNA by nanoparticle-enhanced surface plasmon resonance imaging
    D'Agata, Roberta
    Corradini, Roberto
    Ferretti, Cristina
    Zanoli, Laura
    Gatti, Marcello
    Marchelli, Rosangela
    Spoto, Giuseppe
    BIOSENSORS & BIOELECTRONICS, 2010, 25 (09): : 2095 - 2100
  • [7] Ultrasensitive detection of thrombin using surface plasmon resonance and quartz crystal microbalance sensors by aptamer-based rolling circle amplification and nanoparticle signal enhancement
    He, Peng
    Liu, Lijun
    Qiao, Wenping
    Zhang, Shusheng
    CHEMICAL COMMUNICATIONS, 2014, 50 (12) : 1481 - 1484
  • [8] Surface Plasmon Resonance Imaging signal amplification for the detection of micro-RNAs in the context of organ donation
    Beltrami, Coline
    Moreau, Julien
    Convert, Laurence
    Bryche, Jean-Francois
    Charette, Paul G.
    Canva, Michael
    BIOPHOTONICS IN POINT-OF-CARE III, 2024, 13008
  • [9] Ultrasensitive Detection of Staphylococcus aureus and Listeria monocytogenes Genomic DNA by Nanoparticle-Enhanced Surface Plasmon Resonance Imaging
    Aura, Angela Margherita
    D'Agata, Roberta
    Spoto, Giuseppe
    CHEMISTRYSELECT, 2017, 2 (24): : 7024 - 7030
  • [10] LABEL-FREE DETECTION OF PROTEIN MICROARRAY WITH HIGH THROUGHPUT SURFACE PLASMON RESONANCE IMAGING (SPRI)
    Xu, Shukuan
    Huang, Guoliang
    Deng, Cheng
    Zhu, Jiang
    Han, Chao
    Yang, Xiaoyong
    JOURNAL OF INNOVATIVE OPTICAL HEALTH SCIENCES, 2008, 1 (01) : 107 - 114